ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Ihre Suchhistorie ist leer.
feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
  • 1
    Digitale Medien
    Digitale Medien
    Oxford, UK : Blackwell Publishing Ltd
    Journal of fish biology 46 (1995), S. 0 
    ISSN: 1095-8649
    Quelle: Blackwell Publishing Journal Backfiles 1879-2005
    Thema: Biologie
    Notizen: From the Gong-Shy-Tyan (GST) Stream and the Tanshui River, Taiwan, eels ranged from 5.53 cm t.l. (elvers) to 72.5 cm t.l. Anguilla japonica accounted for 93-99%, A. marmorata 1-7% and A. bicolor pacifica less than 1% of all eels caught. Mean eel lengths increased from 10 cm t.l. at the downstream sites to 50 cm t.l. at the upstream sites. Females made up 92.8% of the sex-determined eels. Population density, averaged approximately 0.14 eel m−2 (2.42 g m−2) and 0.25 eel m−2 (0.92 g m−2) in downstream sites of the GST and Tanshui River, respectively, and decreased substantially with upstream distance. Eels were rarely found in the heavily polluted and dam constructed areas in the midstream site of the Tanshui River.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 65 (1994), S. 2548-2555 
    ISSN: 1089-7623
    Quelle: AIP Digital Archive
    Thema: Physik , Elektrotechnik, Elektronik, Nachrichtentechnik
    Notizen: A special theoretical concept involving the harmonic magnetic-field measurement and analysis method using a fixed angle Hall probe was developed at the Synchrotron Radiation Research Center (SRRC) for measuring as well as analyzing the triple bending achromat magnets of the storage ring. The method can be used to simulate the harmonic magnetic-field calculation of the two-dimensional (2D) "magnet'' program. This method has a quite simple mechanism. The Hall plate was fixed at a 0° angle with respect to the horizontal plane of magnet to measure only the vertical field. Additionally, the 2D nonlinear least-square fitting was used to fit the mapping data so as to find the normal and skew multipole field strength. If necessary, the angle of Hall probe could be rotated 90° precisely for measuring the horizontal field. Consequently, the skew dipole field could be obtained. A real-time Hall-probe automatic magnetic-field measurement system was also developed for fulfilling the concept of the harmonic field measurement. Some special mapping trajectories for different kinds of magnets were discussed to match this special theoretical concept with the analysis methodology. This was done so as to obtain the reliable and accurate harmonic field strength. The accuracy and precision of the harmonic field strength measurement and analysis of this method being better than ±0.01% was confirmed by experimental results.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Digitale Medien
    Digitale Medien
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 69 (1998), S. 1230-1235 
    ISSN: 1089-7623
    Quelle: AIP Digital Archive
    Thema: Physik , Elektrotechnik, Elektronik, Nachrichtentechnik
    Notizen: This work designs and implements an inexpensive and simple double-crystal monochromator, which yields a high performance at a bending magnet x-ray beamline. A primary feature of the proposed monochromator is that the offset between the incident and monochromatic exit of the x-ray beam can be adjusted to cover a wide energy range with a short X–Y traveling stroke. Such a short range of X–Y strokes can reduce the monochromator's overall size and, also, increase the stability of motions. Meanwhile, in this monochromator, instead of using a complicated hardware linkage mechanism, a software program is developed to effectively control the X–Y stage for positioning the second crystal in a fixed exit configuration, alleviating mechanic motion errors to maintain the parallelism of the two crystals. The entire software control mechanical linkage offers a relatively inexpensive and simple assembly monochromator that is more flexible than the commercially available one. © 1998 American Institute of Physics.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    ISSN: 1089-7623
    Quelle: AIP Digital Archive
    Thema: Physik , Elektrotechnik, Elektronik, Nachrichtentechnik
    Notizen: A 4-m-long elliptically polarizing undulator (EPU5.6) device with an Apple-II structure is installed in the Synchrotron Radiation Research Center storage ring. This is the longest EPU device with an Apple-II structure worldwide. The errors of the magnet construction and the assembly process are among the several factors that can degrade the spectral performance. This study describes the mechanical design concept and construction that reduce magnetic field errors to keep high performance of the magnet. The electron orbit distortion in various polarization radiation modes is discussed with reference to a global feedback system and a feed forward table with following gap and phase. The beam dynamic effects are also investigated when the phase and magnetic gap are changed. © 2002 American Institute of Physics.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 5
    Digitale Medien
    Digitale Medien
    Chester : International Union of Crystallography (IUCr)
    Journal of synchrotron radiation 5 (1998), S. 471-474 
    ISSN: 1600-5775
    Quelle: Crystallography Journals Online : IUCR Backfile Archive 1948-2001
    Thema: Geologie und Paläontologie , Physik
    Notizen: A three-orthogonal-Hall-probe assembly with an `on the fly' mapping method has been developed to characterize an elliptically polarizing undulator (EPU). The underlying design concept is that it can measure the three real field components without any field correction under a reliable and synchronization measurement method. Therefore, the relative central position shift, orthogonal angle and the planar Hall effect error between the three Hall probes should be calibrated and readjusted. Experimental results demonstrate that this method can yield an r.m.s. reproducibility of 10 G cm for the three field components and 2 G for the peak field strength. Under precision conditions this system can completely measure the three on-axis field components within 2 min for a 4 m-long EPU.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 6
    ISSN: 1600-5775
    Quelle: Crystallography Journals Online : IUCR Backfile Archive 1948-2001
    Thema: Geologie und Paläontologie , Physik
    Notizen: In this work, a 1 m long Sasaki-type elliptically polarizing undulator (EPU) prototype with 5.6 cm period length is used to examine the mechanical design feasibility as well as magnetic field performance. The magnetic field characteristics of the EPU5.6 prototype at various phase shifts and gap motion are described. The field errors from mechanical tolerances, magnet block errors, end field effects and phase/gap motion effects are analysed. The procedures related to correcting the field with the block position tuning, iron shimming and the trim blocks at both ends are outlined.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 7
    ISSN: 1435-1536
    Schlagwort(e): Contact angles on poly-L-lysine ; plasma treatment of polystyrene surface ; adsorption of poly-L-lysine ; axisymmetric drop shape analysis of poly-L-lysine surfaces
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie , Maschinenbau
    Notizen: Abstract Contact angle data, measured by using a sessile drop arrangement in conjunction with Axisymmetric Drop Shape Analysis-contact Diameter (ADSA-CD), were used to quantify the effects of ammonia gas plasma treatment on the surface properties of previously untreated polystyrene surfaces. The surface tension of treated polystyrene samples is considerably higher than that of untreated samples. The increase in surface tension following plasma treatment is attributed to the addition of amine groups to the surface. Next, conformational changes following the attachment of poly-L-lysine to the untreated samples by simple adsorption and plasma treated samples by covalent bonding were investigated. Surface tension values obtained from contact angle data indicate that conformational changes to poly-L-lysine occur in both cases, because these values are lower than the surface tension of poly-L-lysine in solution. However, contact angle data show that covalently bonded poly-L-lysine undergoes less conformational changes than simply adsorbed poly-L-lysine.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 8
    Digitale Medien
    Digitale Medien
    Springer
    International journal of infrared and millimeter waves 14 (1993), S. 1865-1865 
    ISSN: 1572-9559
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Physik
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 9
    Digitale Medien
    Digitale Medien
    Springer
    International journal of infrared and millimeter waves 13 (1992), S. 769-775 
    ISSN: 1572-9559
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Physik
    Notizen: Abstract The infrared absorption spectrum of neutral magnesium donor impurities in silicon has been investigated under the high resolution of a Fourier-transform infrared spectrometer. The absorption spectrum measured at liquid helium temperature are observed to be clearly better than those reported earlier in the literature. Several new lines corresponding to excitation from ground state to higher excited states have been observed and identified.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 10
    Digitale Medien
    Digitale Medien
    Springer
    International journal of infrared and millimeter waves 16 (1995), S. 339-348 
    ISSN: 1572-9559
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Physik
    Notizen: Abstract Beryllium, when introduced into silicon by thermal diffusion, gives rise to several acceptor impurity centers. The infrared absorption spectrum of beryllium in silicon has been measured with a Fourier-transform spectrometer. The absorption spectrum observed clearly shows five different beryllium acceptor centers in silicon.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...