ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
  • 1
    Digitale Medien
    Digitale Medien
    Springer
    Medical & biological engineering & computing 17 (1979), S. 365-370 
    ISSN: 1741-0444
    Schlagwort(e): Fluorophotometer ; Ophthalmology ; Tear turnover
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Biologie , Chemie und Pharmazie , Medizin
    Notizen: Abstract The use of fluorescein dye for the study of ocular dynamics in ophthalmology is briefly reviewed. General principles for designing objective fluorophotometers for measuring the rate of change of fluorescein concentration are discussed. Details of the circuitry and performance of a new improved objective fluorophotometer using a quartz-halogen excitation source and a synchronous detector are presented. In a preliminary clinical trial the mean tear turnover rate for ten normal subjects was found to be 21±13% min−1.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    Springer
    Medical & biological engineering & computing 24 (1986), S. 386-392 
    ISSN: 1741-0444
    Schlagwort(e): Tear turnover ; Fluorophotometry ; Ophthalmology
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Biologie , Chemie und Pharmazie , Medizin
    Notizen: Abstract An improved continuous reading fluorophotometer with provision for controlling the blink rate has been used to measure tear turnover rates in 14 normal healthy volunteers. A significant difference between morning and afternoon tear turnover results has been found, indicating a possible circadian rhythm in tear flow. Sources of potential systematic error in the measurement method have been identified and analysed. Fluorescence measurements using a thin film cell have confirmed predictions of nonlinearity in fluorophotometer output at high tear film concentrations. The error in tear film fluorescence due to diffusion of fluorescein into the cornea has also been investigated. Simple precautions to minimise these errors are suggested, which should make the measurement method suitable for clinical application.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...