ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
  • 1
    Digitale Medien
    Digitale Medien
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 19 (1985), S. 99-113 
    ISSN: 0021-9304
    Schlagwort(e): Chemistry ; Polymer and Materials Science
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Medizin , Technik allgemein
    Notizen: Assessment of potentially thromboresistant polymers and other materials has been impeded by the lack of a simple and safe test procedure in man. This report describes the use of a portable gamma radiation detector to assess accumulation of 125I-fibrinogen in thrombi related to intravenous cannulae. The method was first employed in 19 dogs and one sheep with FEP-Teflon forelimb intraveneous cannulae which were scanned for up to 6 h after insertion. Results were compared with findings at post mortem examination. Eleven thrombi developed, nine of which emitted more than 3500 counts per minute; eight of these (89%) were detected by external scanning. The smallest thrombus detected weighed 0.7 mg. The method did not distinguish between thrombus and hematoma. Fifty FEP-Teflon cannulae were then studied in 39 patients after injection of 100 μCi 125I-fibrinogen. Cannulae and control sites were scanned twice daily and an independent blind clinical appraisal was performed by an experienced nurse. A rise in percentage uptake (count at a limb site/heart count × 100) of 20 or a difference of 40 between adjacent sites was regarded as a positive test. Scans became positive up to 30 h before clinical evidence of phlebitis was observed. The interval between insertion and thrombosis of both large and small cannulae detected by scanning was significantly shorter than that determined by clinical assessment (p 〈 0.001). Physical signs of phlebitis were noted with 58% of large cannulae (16 or 18 gauge) and 33% of small cannulae (22 gauge) at the time of removal. Positive 125I-fibrinogen tests were obtained with 70% of large cannulae and 75% of small cannulae. 125I-fibrinogen scanning is a safe simple sensitive technique to detect thrombosis related to intravenous cannulae. The test should enable comparisons of different cannula materials in man.
    Zusätzliches Material: 8 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...