ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • Dip-coated electroenzymic glucose transducer  (1)
  • solid (gel) phase  (1)
Sammlung
Verlag/Herausgeber
Erscheinungszeitraum
  • 1
    Digitale Medien
    Digitale Medien
    Amsterdam : Elsevier
    International Journal of Biological Macromolecules 4 (1982), S. 233-243 
    ISSN: 0141-8130
    Schlagwort(e): Phenolic resins ; peptide synthesis ; poly(acryloylmorpholine) ; solid (gel) phase
    Quelle: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Thema: Biologie , Chemie und Pharmazie
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    Springer
    Medical & biological engineering & computing 23 (1985), S. 108-115 
    ISSN: 1741-0444
    Schlagwort(e): Dip-coated electroenzymic glucose transducer ; In vitroperformance ; Optimisation
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Biologie , Chemie und Pharmazie , Medizin
    Notizen: Abstract The details of construction and the performance characteristics of a dipcoated electroenzymic glucose transducer comprising an H2O2 electrode coated with a layer of glucose oxidase encapsulated in cellulose acetate and overlaid with a layer of polyurethane are presented. The steady-state current increases when the glucose oxidase and cellulose acetate concentrations of the dip-coating solutions are increased, but high cellulose acetate concentrations yield thick and mechanically unstable membranes. A compromise between current yield and mechanical stability can, however, be achieved by employing glucose oxidase and cellulose acetate concentrations of 200 mg ml−1 and 2–5 g 100 ml−1, respectively. A polyurethane concentration of 6 g 100ml−1 is optimal both in terms of the current yield and the linearity of response. The relationship between steady-state current and D-glucose concentration is approximately linear over the concentration range 0·5 to 11·5 mm, and if correction is made for deviations from linearity at higher glucose concentrations, concentrations in excess of 20 mM can readily be quantified. The steady-state current is pH and temperature dependent, but the dependencies are relatively small in the physiological range. The mean rate of decrease of the glucose current during long-term operation of the optimised transducer is 0·83 per cent of the initial current per hour at 37°C. The hydrated electrodes perform satisfactorily after storage for more than two weeks at room temperature. the transducers have a mean response time [t 90%] of 50 s or less.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...