ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
Sammlung
Erscheinungszeitraum
  • 1
    Publikationsdatum: 2020-07-16
    Beschreibung: Background: Hospital-acquired infections (HAIs) remain a common problem, which suggests that standard decontamination procedures are insufficient. Thus, new methods of decontamination are needed in hospitals. Methods: We assessed the effectiveness of a no-touch automated disinfection (NTD) system in the decontamination of 50 surfaces in 10 hospital rooms. Contamination of surfaces was assessed with a microbiological assay and an ATP bioluminescence assay. Unacceptable contamination was defined as 〉 100 colony forming units/100 cm2 in the microbiological assay, and as ≥ 250 relative light units in the ATP assay. Results: When measured with the microbiological assay, 11 of 50 surfaces had unacceptable contamination before NTD, and none of the surfaces had unacceptable contamination after NTD (p 〈 0.001). On the ATP bioluminescence assay, NTD decreased the number of surfaces with unacceptable contamination from 28 to 13, but this effect was non-significant (p = 0.176). On the microbiological assay taken before NTD, the greatest contamination exceeded the acceptable level by more than 11-fold (lamp holder, 1150 CFU/100 cm2). On the ATP bioluminescence assay taken before NTD, the greatest contamination exceeded the acceptable level by more than 43-fold (Ambu bag, 10,874 RLU). Conclusion: NTD effectively reduced microbiological contamination in all hospital rooms. However, when measured with the ATP bioluminescence assay, the reduction of contamination was not significant.
    Print ISSN: 1661-7827
    Digitale ISSN: 1660-4601
    Thema: Energietechnik , Medizin
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Publikationsdatum: 2020-08-12
    Beschreibung: Autopsies of exhumed bodies pose a risk of infections with environmental bacteria or fungi, which may be life-threatening. Thus, it is important to use effective methods of disinfection in forensic pathology facilities. In this study, we investigated the effectiveness of no-touch automated disinfection (NTD) system after autopsies of exhumed bodies. Directly after 11 autopsies of exhumed bodies, we used an NTD system based on a peroxone vapor to disinfect the air and surfaces. We measured microbial burden in the air and on surfaces before and after NTD. The NTD system reduced the mean bacterial burden in the air from 171 colony forming units (CFU)/m3 to 3CFU/m3. The mean fungal burden in the air decreased from 221 CFU/m3 to 9CFU/m3. The mean all-surface microbial burden was 79 CFU/100 cm2 after all autopsies, and it decreased to 2 CFU/100 cm2 after NTD. In conclusion, the peroxone-based NTD system was effective for decontamination of the air and surfaces in a dissecting room after autopsies of exhumed bodies.
    Digitale ISSN: 2076-0817
    Thema: Biologie , Medizin
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...