ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Publication Date: 2011-08-24
    Description: The Far Infrared Limb Observing Spectrometer (FILOS) is an instrument designed to measure chemical species in the upper atmosphere using limb emission in the FIR region of the spectrum. FILOS uses three Fabry-Perot etalons in series to obtain a resolution of 0.0017/cm near 100/cm (100 microns). It is compact and has low power and low data rate requirements so that it may be flown as an auxiliary balloon payload with larger instruments. FILOS has two 0.05/cm bandwidth channels which are currently tuned to a HCl line at 104.2/cm and a pair of OH lines at 101.3/cm. The instrument is described in further detail and results are presented from two recent balloon flights in which OH was measured as a function of time on one hour centers from sunrise to sunset.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: In: Optical methods in atmospheric chemistry; Proceedings of the Meeting, Berlin, Germany, June 22-24, 1992 (A93-51501 22-35); p. 451-456.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2016-06-07
    Description: High resolution rotational spectroscopy has long been central to remote sensing techniques in atmospheric sciences and astronomy. As such, laboratory measurements must supply the required data to make direct interpretation of data for instruments which sense atmospheres using rotational spectra. Spectral measurements in the microwave and far infrared regions are also very powerful tools when combined with infrared measurements for characterizing the rotational structure of vibrational spectra. In the past decade new techniques were developed which have pushed high resolution spectroscopy into the wavelength region between 25 micrometers and 2 mm. Techniques to be described include: (1) harmonic generation of microwave sources, (2) infrared laser difference frequency generation, (3) laser sideband generation, and (4) ultrahigh resolution interferometers.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA, Goddard Space Flight Center, First International Conference on Laboratory Research for Planetary Atmospheres; p 27-36
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 2011-08-19
    Description: An apparatus is described that will measure absolute absorption of millimeter radiation in gases. The method measures the change in the quality factor of a Fabry-Perot resonator with and without gas present. The magnitude of the change is interpreted in terms of the absorption of the lossy medium inside the resonator. Experiments have been performed on the 115-GHz CO line and the 119-GHz O2 line at two different temperatures to determine the linewidth parameter and the peak absorption value. These numbers can be combined to give the integrated intensity which can be accurately calculated from results of spectroscopy measurements. The CO results are within 2 percent percent of theoretically predicted valves. Measurements on O2 have shown that absorption can be measured as accurately as 0.5 dB/km with this technique. Results have been obtained for oxygen absolute absorption in the 60-80-GHz region.
    Keywords: ATOMIC AND MOLECULAR PHYSICS
    Type: IEEE Transactions on Antennas and Propagation (ISSN 0018-926X); 36; 1136-114
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Publication Date: 2011-08-19
    Description: The dimerization products of the ClO + ClO reaction were investigated in a flowing chemical reactor using submillimeter wave spectroscopy. The major products were identified as the chlorine peroxide (Cl2O2) and chlorine dioxide (OClO). The rotational constants as well as a complete set of quartic centrifugal distortion constants were determined. The identification of the chlorine peroxide supports the earlier proposed ClO-dimer mechanisms, which partly explain the ozone hole formation during the Antarctic springtime.
    Keywords: ATOMIC AND MOLECULAR PHYSICS
    Type: Journal of Chemical Physics (ISSN 0021-9606); 91; 6588-659
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Publication Date: 2011-08-19
    Description: A complete dual-frequency cryogenic heterodyne receiver operating at 183 and 380 GHz is described. The cooled mixers are whisker-contacted GaAs Schottky diodes mounted in reduced-height fundamental-mode waveguide. The local oscillators are Gunn-oscillator-driven multipliers using GaAs varactor diodes as the harmonic generators. Quasi-optical techniques are used extensively for coupling the remote and local oscillator signals into the mixers. The overall system double side-band (DSB) noise temperature is 320 K for the 183-GHz receiver and 650 K for the 380 GHz receiver.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: IEEE Transactions on Microwave Theory and Techniques (ISSN 0018-9480); 36; 694-700
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Publication Date: 2011-08-19
    Description: Far-infrared CW radiation of 1.25 watts has been obtained at the 119 micron methanol line with a CO2 pump power of 125 watts, and the maximum frequency fluctuation of the free running laser is measured to be less than + or - 100 kHz per hour. Reflecting optics have been used, when possible, to minimize CO2 degradation, and the frequency stability is ensured by cooling the input and output couplers. The input and output assemblies within the lasing medium are enclosed to minimize the external effects on the cavity length and to eliminate the mechanical instabilities associated with the use of bellows. The vibrational bottle-neck is broken by cooling the resonator wall to 5 deg and adding He as the buffer gas.
    Keywords: LASERS AND MASERS
    Type: International Journal of Infrared and Millimeter Waves (ISSN 0195-9271); 8; 441-447
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Publication Date: 2018-06-08
    Keywords: Astrophysics
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Publication Date: 2018-06-08
    Keywords: Lasers and Masers
    Type: Ohio State University; Columbus, OH; United States
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Publication Date: 2019-06-28
    Description: A method for generating tunable far-infrared radiation is described. The apparatus includes a Schottky-barrier diode which has one side coupled through a conductor to a waveguide that carries a tunable microwave frequency; the diode has an opposite side which is coupled through a radiating whisker to a bias source. Infrared light is directed at the diode, and infrared light with tunable sidebands is radiated by the whisker through an open space to a reflector. The original infrared is separated from a tunable infrared sideband by a polarizing Michelson interferometer.
    Keywords: LASERS AND MASERS
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Publication Date: 2018-06-11
    Description: The Earth Observing System Microwave Limb Sounder measures several atmospheric chemical species (OH, HO2, H2O, O3, HCl, ClO, HOCl, BrO, HNO3, N2O, CO, HCN, CH3CN, volcanic SO2), cloud ice, temperature, and geopotential height to improve our understanding of stratospheric ozone chemistry, the interaction of composition and climate, and pollution in the upper troposphere. All measurements are made simultaneously and continuously, during both day and night. The instrument uses heterodyne radiometers that observe thermal emission from the atmospheric limb in broad spectral regions centered near 118, 190, 240, and 640 GHz, and 2.5 THz. It was launched July 15, 2004 on the National Aeronautics and Space Administration's Aura satellite and started full-up science operations on August 13, 2004. An atmospheric limb scan and radiometric calibration for all bands are performed routinely every 25 s. Vertical profiles are retrieved every 165 km along the suborbital track, covering 82 S to 82 N latitudes on each orbit. Instrument performance to date has been excellent; data have been made publicly available; and initial science results have been obtained.
    Keywords: Earth Resources and Remote Sensing
    Type: IEEE Transactions on Geoscience and Remote Sensing (ISSN 0196-2892); Volume 44; No. 5; 1075-1092
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...