ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Articles  (2)
  • Polymer and Materials Science  (2)
Collection
  • Articles  (2)
Keywords
Publisher
Years
Topic
  • 1
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: A surface modification technique was developed to achieve controlled release of gentamicin from implanted polyurethane (PU) rat lead samples. PU tubing first was provided with an acrylic acid/acrylamide copolymer surface graft and then loaded with gentamicin. This surface modification technique resulted in release of gentamicin base (GB) and was applied either to the inner luminal surface only (PU-GB-1x) or to both the inner and outer surfaces (PU-GB-2x). First we investigated whether the early tissue response was harmfully compromised when surface-modified rat lead samples were implanted without any infectious challenge. Additionally, the efficacy of this type of local gentamicin therapy was investigated by establishing its effect on tissue response and its ability to prevent lead-related infections after inoculation with Staphylococcus aureus. It was demonstrated that the applied surface modification(s) did not induce adverse effects although an increase in the infiltration of granulocytes and macrophages and an increase in the formation of wound fluid and fibrin were observed. This effect was stronger with PU-GB-2x than with PU-GB-1x. With bacterial inoculation the applied surface modification successfully suppressed the infectious challenge, PU-GB-2x more effectively than PU-GB-1x. PU-GB-2x also was more effective when compared to the gentamicin-delivery methods discussed in the first part of this two-part study, i.e., release through a vicinal gentamicin-containing collagen sponge and preoperative gentamicin solution-dipping of rat lead samples. © 1997 John Wiley & Sons, Inc.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The effect of local gentamicin release through a vicinal collagen sponge or through preoperative solution-dipping of rat lead samples was investigated in an early-infection model. The efficacy of these methods and their effect on tissue response were determined. It was demonstrated that both methods of local gentamicin release suppress lead-related infectious complications as compared to the control lead, which showed a high presence of inflamed/infected tissues and bacterial growth at each explantation time point. The first day the vicinal collagen sponge was more effective in suppressing the infection than was the solution-dipped lead, probably because there is a faster and higher dose release of gentamicin from the sponge. However, continued implantation time revealed that gentamicin release from the solution-dipped lead was more effective than the sponge. This supports our hypothesis that the presence of lumina are decisive for bacterial growth and persistence of implant-related infections. © 1997 John Wiley & Sons, Inc.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...