ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • thermal conductivity  (3)
  • Springer  (3)
  • IWA Publishing
  • Washington, DC : United States Gov. Print. Off.
  • American Association of Petroleum Geologists (AAPG)
Collection
Publisher
  • Springer  (3)
  • IWA Publishing
  • Washington, DC : United States Gov. Print. Off.
  • American Association of Petroleum Geologists (AAPG)
Years
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    International journal of thermophysics 11 (1990), S. 597-601 
    ISSN: 1572-9567
    Keywords: measurement techniques ; nitrogen ; parallel-plate apparatus ; thermal conductivity
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract A parallel-plate apparatus is suited for accurate measurements of the thermal conductivity coefficient of fluids over a wide range of densities. This is illustrated by measurements of the thermal conductivity coefficient of nitrogen at a temperature of 308.15 K and at pressures up to 20.1 MPa with an accuracy of 0.5%. The agreement with a recent correlation based on accurate measurements by other authors is satisfactory.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    International journal of thermophysics 10 (1989), S. 409-415 
    ISSN: 1572-9567
    Keywords: critical region ; ethane ; thermal conductivity ; thermal diffusivity
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract The thermal conductivity of ethane in the critical region has been measured isochorically at densities up to 1.76 times the critical density and at temperatures down to 0.13 K above the critical temperature. The measurements were performed with a thermal conductivity apparatus based on the parallelplate method. The experimental accuracy was 0.5 to 5%, depending on the distance to the critical point. The experimental results agree well with a recently developed crossover theory for the thermal diffusivity of fluids in the critical region.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1572-9567
    Keywords: critical phenomena ; parallel-plate method ; thermal conductivity
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract A description is presented of the construction and operating procedure of an improved guarded parallel-plate instrument for measuring the thermal conductivity of fluids in the critical region. With the improved arrangement, it has been possible to reduce the temperature differences across the fluid layer between the two horizontal plates to values as low as 0.3 mK, thus allowing the thermal conductivity of fluids to be measured at temperatures as close as 20 mK to the critical temperature. The instrument has been used to measure the thermal conductivity of methane and of a mixture of methane and ethane in the close vicinity of the critical point.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...