ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • rare earths  (2)
  • 1990-1994  (2)
  • 1935-1939
Collection
Publisher
Years
  • 1990-1994  (2)
  • 1935-1939
Year
  • 1
    ISSN: 1436-5073
    Keywords: rare earths ; terbium oxide ; inductively coupled plasma atomic emission spectrometry (ICP-AES)
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract Inductively coupled plasma atomic emission spectrometry (ICP-AES) was employed to determine Y, Sm, Eu, Gd, Dy, Ho and Er in high purity terbium oxide. Terbium oxide was dissolved in 0.5 mol/l HNO3 and nebulized into the plasma generated by a 56 MHz RF generator at 1.5 kW output power. Using a Jobin-Yvon 1-m Czenry-Turner high resolution, high dispersion scanning monochromator, lines mutually interference-free as well as free of interference from the matrix Tb were chosen for the seven analytes. A set of standards containing the analytes in the concentration range 0.01–1.0 gmg/ml with 1 mg/ml Tb was used for calibration. It was necessary to apply background correction to the gross analyte line intensities in order to obtain linear calibration plots for the analytes.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1436-5073
    Keywords: yttrium oxide ; rare earths ; inductively coupled plasma-atomic emission spectrometry (ICP-AES)
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract Traces of heavy rare earth elements (Eu-Lu) were determined in high purity yttrium oxide by inductively coupled plasma atomic emission spectrometry. The yttrium oxide samples were dissolved in nitric acid and the solutions analyzed with a plasma produced by a 56 MHz RF generator at an output power of 1.5 kW. Using a high resolution sequential monochromator, interference-free spectral lines for Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb and Lu could be found for calibration. The detection limits for the above elements have been found to be slightly higher in the presence of yttrium matrix, than in aqueous solution. This could be attributed to background enhancements due to the presence of yttrium. The mean RSD of the method varied between 2.3% and 6.3% in the concentration range 0.01 and 0.5 μg/ml. The percentage recovery ranged from 84 to 106 for the different rare earth elements.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...