ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Man/System Technology and Life Support  (1)
  • nitric oxide  (1)
Collection
Keywords
Publisher
Years
  • 1
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 37 (1997), S. 182-189 
    ISSN: 0021-9304
    Keywords: diazeniumdiolate ; nitric oxide ; microspheres ; polyethyleneimine ; vascular grafts ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Over the years, many attempts have been made to increase the patency of small- to medium-sized prosthetic vascular grafts. However, none of them has greatly affected long-term rates. Recently, nitric oxide (NO) has been shown to inhibit thrombus formation in such grafts, suggesting that local delivery of NO may help to increase graft patency. This study describes the site-specific delivery of NO by entrapping NO-releasing microspheres in the pores of a vascular graft. NO-releasing polyethyleneimine microspheres (PEIX) were developed using a novel water-in-oil emulsion technique involving chemical crosslinking with a bis-epoxide. The PEIX microspheres were then derivatized with NO forming the [N(O)NO]- moiety of the diazeniumdiolates formerly known as NONOates. These polymeric NO-releasing particles were found to spontaneously release 194 nmol NO/mg with a half-life of over 66 h under physiologic conditions. Fluorescein isothiocyanate-labeled microspheres were then embedded into the pores of a 60-μm nonreinforced Gore-tex vascular graft using a simple evacuation technique and evaluated for microsphere placement and NO release. Scanning electron microscopic analysis showed the microspheres entrapped in the pores of the vascular graft releasing 10 nmol NO/mg with a half-life of 51 h. The microspheres remained entrapped in the graft even after immersion and NO release, as confirmed by fluorescence of the medium. These results suggest that NO-releasing particles can be incorporated into the pores of a vascular graft to deliver therapeutic amounts of NO for the prevention of thrombosis in small-diameter prosthetic grafts. © 1997 John Wiley & Sons, Inc. J Biomed Mater Res, 37, 182-189, 1997.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2019-07-12
    Description: TIIMS is used during the inspection phases of every mission to provide quick visual feedback, detailed inspection data, and determination to the mission management team. This system consists of a visual Web page interface, an SQL database, and a graphical image generator. These combine to allow a user to ascertain quickly the status of the inspection process, and current determination of any problem zones. The TIIMS system allows inspection engineers to enter their determinations into a database and to link pertinent images and video to those database entries. The database then assigns criteria to each zone and tile, and via query, sends the information to a graphical image generation program. Using the official TIPS database tile positions and sizes, the graphical image generation program creates images of the current status of the orbiter, coloring zones, and tiles based on a predefined key code. These images are then displayed on a Web page using customized JAVA scripts to display the appropriate zone of the orbiter based on the location of the user's cursor. The close-up graphic and database entry for that particular zone can then be seen by selecting the zone. This page contains links into the database to access the images used by the inspection engineer when they make the determination entered into the database. Status for the inspection zones changes as determinations are refined and shown by the appropriate color code.
    Keywords: Man/System Technology and Life Support
    Type: MSC-24484-1 , NASA Tech Briefs, September 2011; 48-49
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...