ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Oxidation of metals 31 (1989), S. 123-143 
    ISSN: 1573-4889
    Keywords: high-temperature sulfidation ; fluidized bed combustor ; nickel-base alloys ; 300-series stainless steels
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Notes: Abstract The modes of initiation and propagation of corrosion attack on a series of high-temperature alloys were studied in synthetic gas mixtures at 900°C. The gas mixtures were intended to simulate the oxygen and sulfur partial pressures experienced in reducing zones in a coal-fired fluidized-bed combustor and comprised mixtures of CO, CO2, and SO2. The alloys studied were candidates for in-bed heat exchanger tubing for an air-heater cycle operating at 843°C and 300–500 psig and so ranged from type 300-series stainless steels to nickel-base alloys. With the exception of two FeCrAlY alloys and types 304 and 347 stainless steels, it was found that sulfidation corrosion could be initiated on all the alloys within 0.25 hr; the rate of propagation of the corrosive attack depended on the flux of SO2 in the environment and on the nickel content of the alloys. The presence of iron in the alloys appeared to slow the initiation of sulfidation, by forming a continuous iron oxide layer. The effects of various alloying additions are discussed, and a schematic model for the initiation of sulfidation is proposed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1573-4889
    Keywords: sulfidation ; nickel-base alloys ; iron-base alloys ; fluidized-bed combustion ; deposit-related attack
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Notes: Abstract This study addresses questions concerning the likelihood of sulfidation attack of heat-exchanger alloys beneath deposits of sulfur-sorbent material in fluidized-bed combustors. Alloy specimens were exposed at 900°C in calcium sulfate-calcium oxide and calcium sulfide-calcium oxide mixtures, in environments in which the oxygen partial pressures were fixed at values corresponding to the equilibrium values for each solids mixture, using controlled ratios of CO and CO2. The only source of sulfur in these systems was the calcium sulfate or sulfide. Sulfidation attack of nickel-base alloys occurred in both mixtures, the calcium sulfide-calcium oxide mixture being the more aggressive. Iron-base alloys were less susceptible to attack, although susceptibility increased with increasing nickel content. FeCrAlY-type alloys were resistant to attack. Comparison with corrosion behavior under conditions in which the oxygen and sulfur partial pressures were the same as those used here, but in which the sulfur source was in the gas phase, indicates that the form of the sulfidation attack is similar but that its progress is much slower under solid deposits.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 4 (1990), S. 108-113 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: A method is described whereby, under software control, the scan function employed to collisionally excite ions in an ion-trap mass spectrometer is regulated so as to obtain parent ion (fixed product) tandem mass spectral data. At the same time, constant neutral-loss information is also provided. Key features are the automatic ‘intelligent’ selection of parent ions from observation of the initial mass spectrum and the scanning of the applied ‘tickle’ frequency in order to locate the precise resonance points for excitation of these ions. Results for the model compounds perfluorotributylamine (‘FC43’) and n-butylbenzene are reported and complicating effects such as the unimolecular decay of the precursor ion species and charge exchange between product ions and the original sample material are discussed.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 4 (1990), S. 415-417 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: The aims of the investigation were to use the method of dynamically programmed scans to study in detail some tandem mass spectrometric characteristics of the ion-trap mass spectrometer and then to use the programs to investigate the possibility of performing benchtop gas chromatography/tandem mass spectrometry experiments on the standard instrument. In particular we have examined the effect of applying a DC ramp during the ‘tickle’ period as a means of broadening the range of resonant frequencies, thereby facilitating the tuning required to effect excitation.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 2 (1988), S. 55-58 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 15 (1988), S. 239-242 
    ISSN: 0887-6134
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 9 (1986), S. 73-77 
    ISSN: 0935-6304
    Keywords: Capillary supercritical fluid chromatography ; Fast analysis ; Nonvolatile analytes ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Capillary supercritical fluid chromatography (SFC) is proving to be a viable and useful separation method for thermally labile and nonvolatile materials. As with other capillary chromatographic techniques, very fast separations can be accomplished by sacrificing total efficiency and optimizing the conditions for rapid analysis. This is achieved using short, small-bore capillary columns, increased mobile phase linear velocities and very fast pressure programming rates. These principles are demonstrated for the rapid separation of selected component systems.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 19 (1990), S. 286-294 
    ISSN: 1052-9306
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The electrospray ionization (ESI) and plasma desorption (PD) mass spectra of over 20 peptides and proteins, with molecular weights (Mr) ranging between 1182 and 143000, have been directly compared. Both techniques produced molecular ions for the majority of materials studied; however, neither approach proved to be universally applicable. PD failed for a number of proteins that were successfully analyzed by ESI, including some of very high Mr. On the other hand, ESI failed for proteins that apparently could not acquire a sufficient number of positive charges to allow transmission through the quadrupole mass filter. A non-covalently bound adduct, ribonuclease S, did not survive either method intact and a simple glycoprotein, ribonuclease B, did not yield the expected molecular ion with either approach. The mass measurement accuracy of quadrupole ESI is five to tenfold better than obtained with a commercial time-of-flight PD mass spectrometer. Furthermore, ESI's superior mass resolution (with quadrupole mass spectrometers) will prove to be particularly helpful for the characterization of mixtures of closely related materials. Sensitivity was only compared qualitatively but is highly compound dependent with both techniques. In favorable cases, ESI spectra can be obtained on low femtomolar quantities of proteins while PD typically requires several hundred femtomoles to high picomoles, depending on a number of factors including Mr.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 17 (1988), S. 411-414 
    ISSN: 1052-9306
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 1052-9306
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Herein, we present the first example of charge state specific facile gas-phase cleavage of an aspartic acid-methionine peptide linkage. This cleavage (Asp 75-Met 76) was observed in the α-chain of human adult hemoglobin (Hb) and was probed by electrospray ionization mass spectrometry. This specific conformational and/or charge density dependent dissociation was observed primarily in the [M + 11H]11+ and [M + 12H]12+ species. A mechanism involving an intramolecular proton transfer from the protonated carboxyl side chain of Asp 75 to the neighboring Met 76 residue yielding an anhydride moiety at the C-terminal of the Asp 75 is proposed. Dramatic differences in dissociation of [M + 13H]13+ and [M + 14H]14+ species were observed.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...