ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1573-0662
    Keywords: Dimethyl sulfide ; isotope dilution ; gas chromatography ; mass spectrometry ; troposphere
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Geosciences
    Notes: Abstract Stable isotopic dilution was applied to the determination of dimethyl sulfide (DMS) in ambient air at the low part-per-trillion by volume (pptrv) levels. Perdeuterated DMS was used as an internal standard in the gas chromatography/mass spectrometry determination. The isotopically labelled internal standard provided insensitivity to possible losses of DMS in sampling and analysis. The lower limit of detection (LLD) was 1 pptrv with a sample acquisition time of 2 min.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1573-0662
    Keywords: Dimethyl sulfide ; sulfur dioxide ; isotope dilution ; gas chromatography ; mass spectrometry ; grab sampling
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Geosciences
    Notes: Abstract Developments allowing the direct determination of sulfur dioxide and dimethyl sulfide in grab samples by gas chromatography/mass spectrometry with isotopically labeled standards (GC/MS/ILS) are reported. Isotopomers of DMS and SO2 are used as internal standards. Spiked air samples are dried to a dew point of 〈−60 °C and trapped cryogenically in loops of Teflon tubing. Sealed samples are transported to the laboratory under liquid nitrogen and later subjected to GC/MS analysis. Holding times of up to one month do not result in significant sample loss. For samples collected in a clean marine environment, concentrations of SO2 and DMS greater than 5 and 8 pptv, respectively, are significantly different from blanks at the 95% confidence level. Average measurement precision derived from a propagation of errors are 9% for SO2 and 42% for DMS at concentrations from 5–15 pptv. Improvements are outlined which should provide sensitivity and precision comparable to that of on-site GC/MS. The technique will allow increased flexibility for the determination of trace sulfur species in the field under conditions where deployment of a mass spectrometer is not possible.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...