ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 16 (1993), S. 419-421 
    ISSN: 0935-6304
    Keywords: Liquid chromatography ; Indirect conductimetric detection ; Cyclodextrin ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Indirect conductimetric detection of cyclodextrins (CDs) was investigated in liquid chromatography (LC). The mobile phase contained an electrolytic substance which maintained high background, and CDs were indirectly detected owing to a depression of the background signal due to dilution of the mobile phase by the analyte molecules. The dynamic reserve, defined as the ratio of the background to its noise level, was (1-2) × 105, and the detection limits at S/N = 3 were 23-40 ng for CDs when a microcolumn LC system was employed.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 0935-6304
    Keywords: Liquid chromatography ; Cation-exchange-induced stationary phases ; Retention behavior ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The retention behavior of aromatic hydrocarbons and dansylamino acids on cation-exchangers modified with alkylammonium ions has been examined by microcolumn liquid chromatography. Several parameters affected the retention of analytes, involving concentration of the modifier in the mobile phase, its alkyl chain length and mobile phase composition. Stationary phases modified with a reagent having longer alkyl chains achieved better column efficiency.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 23 (2000), S. 590-594 
    ISSN: 0935-6304
    Keywords: Ion chromatography ; graphitic carbon stationary phases ; anions ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---Inorganic anions could be separated on porous graphitic carbon stationary phases in ion chromatography. Ion exchange between eluent anions and sample anions on the stationary phase was confirmed by the retention behavior and the possibility of indirect photometric detection. The elution order of anions was different from that observed for commercially available anion exchangers. Chloride, nitrate, and sulfate contained in tap water could be determined in 7 min.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...