ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Spektralphotometrie, Atomabsorption  (4)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 269 (1974), S. 337-339 
    ISSN: 1618-2650
    Keywords: Best. von Magnesium ; Spektralphotometrie, Atomabsorption ; Untersuchung von Störungen
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary Optimum conditions and the influence of 54 ions on the determination of magnesium by atomic absorption spectrophotometry have been investigated. The use of the nitrous oxide-acetylene flame will remove any interference effects. In the air-acetylene flame the standard additions technique was studied and proved to be suitable except when silicate was present. Completely satisfactory determinations were obtained when the standard additions technique was applied to solutions containing an alkaline earth metal as a releasing agent.
    Notes: Zusammenfassung Die optimalen Bedingungen sowie der Einfluß von 54 Ionen wurden untersucht. Durch Verwendung der N2O-Acetylen-Flamme werden alle Störungen vermieden. In der Luft-Acetylen-Flamme erwies sich die Methode der Standardzugaben als geeignet, außer bei Gegenwart von Silicat. Alle Störungen können auch in dieser Flamme unterbunden werden, wenn die Methode der Standardzugaben zusammen mit einem Zusatz eines anderen Erdalkalimetalls angewendet wird.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 270 (1974), S. 177-179 
    ISSN: 1618-2650
    Keywords: Best. von Strontium ; Spektralphotometrie, Atomabsorption ; Vermeidung von Störungen
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary Recommended operating conditions for the determination of strontium by atomic absorption spectrophotometry are given for both the air-acetylene and nitrous oxide-acetylene flames. Details are given of interference effects which can occur in the air-acetylene flame and also of a method to eliminate these effects using lanthanum as a releasing agent. In the nitrous oxide-acetylene flame no interference effects occurred if all solutions measured contained an ionisation buffer.
    Notes: Zusammenfassung Arbeitsbedingungen werden für die Luft-Acetylen- und die N2O-Acetylen-Flamme gegeben. Die Störungen, die in der Luft-Acetylen-Flamme auftreten, werden im einzelnen besprochen und ihre Ausschaltung durch Lanthanzusatz beschrieben. In der N2O-Acetylen-Flamme treten keine Störungen auf, wenn die Lösungen einen Ionisierungspuffer enthalten.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 268 (1974), S. 177-180 
    ISSN: 1618-2650
    Keywords: Best. von Calcium ; Spektralphotometrie, Atomabsorption ; Ausschaltung von Störungen
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary Optimum conditions and the influence of 53 ions on the determination of calcium by atomic absorption spectrophotometry have been investigated. In the nitrous oxide-acetylene flame interferences are caused by elements with low ionisation potentials. In the air-acetylene flame a number of cations and anions interfere by the formation of refractory compounds. The simple standard additions procedure was unable to overcome these interferences in the concentration ranges investigated, but did give accurate results when used in combination with a releasing agent (strontium).
    Notes: Zusammenfassung Optimale Bedingungen und Beeinflussung durch 53 verschiedene Ionen wurden untersucht. Bei Verwendung der N2O/Acetylen-Flamme werden Störungen durch Elemente mit niedrigen Ionisations-potentialen verursacht. In der Luft/Acetylen-Flamme stören eine Reihe von Kationen und Anionen durch Bildung hitzebeständiger Verbindungen. Die Anwendung der Standardzugabe-Methode ergab nur befriedigende Resultate in Kombination mit einem Strontiumzusatz.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 268 (1974), S. 180-184 
    ISSN: 1618-2650
    Keywords: Best. von Barium ; Spektralphotometrie, Atomabsorption ; Ausschaltung von Störungen
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary Optimum conditions for the determination of barium in both the air-acetylene and nitrous oxide-acetylene flames have been given and the influence of 50 ions on the barium absorbance has been investigated. In the nitrous oxide-acetylene flame no interference effects occurred and the sensitivity was much better than that obtained with the air-acetylene flame in which several ions caused interference. The standard additions method failed to overcome these interferences but did give satisfactory results when used in conjunction with a releasing agent.
    Notes: Zusammenfassung Optimale Bedingungen für die Bestimmung von Barium in der Luft/C2H2- und N2O/C2H2-Flamme werden angegeben und der Einfluß von 50 Ionen auf die Bariumabsorption beschrieben. Im Falle der N2O/C2H2-Flamme wurden keine Störungen beobachtet; die Empfindlichkeit ist besser als bei Verwendung der Luft/C2H2-Flamme, in der Störungen durch mehrere Ionen auftraten. Das Verfahren der Standardzugabe gab nur dann befriedigende Ergebnisse, wenn es in Verbindung mit einem Zusatz von Strontium oder Lanthan verwendet wurde.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...