ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Other Sources  (2)
  • SPACECRAFT INSTRUMENTATION  (2)
Collection
  • Other Sources  (2)
Years
  • 1
    facet.materialart.
    Unknown
    In:  Other Sources
    Publication Date: 2011-08-18
    Description: Preflight and in-orbit sensor and data measurements indicate that TM meets or exceeds most specifications. Measured spectral band edges meet instrument specifications in 12 out of 14 cases; there is ample dynamic range. The signal-to-noise ratio exceeds specifications, except for band 3, channel 4; and band 7 channel 7 is very noisy but still meets specifications. The modulation transfer function of channel 4, band 2, is smaller than specified. Registration errors between the primary focal plane (PFP) and the cold focal plane (CFP) are about 0.75 pixels along-scan and 0.2 pixels across scan. Forward and reverse scan discontinuities are well within ground-processing capabilities to rectify. Instrument gain variability, up to 7 percent for band 5, requires use of the internal calibration (IC) system to assure radiometric accuracy. Preliminary applications evaluation of image contents indicates that TM provides much better definition of edges than MSS.
    Keywords: SPACECRAFT INSTRUMENTATION
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2011-08-19
    Description: Relative spectral response data for the Landsat-4 and Landsat-4 backup multispectral scanner subsystems (MSS), the protoflight and flight models, are presented and compared to similar data for the Landsat 1, 2 and 3 scanners. Channel (six channels per band) outputs for soil and soybean targets were simulated and compared within each band and between scanners.The principal differences between the spectral responses of the Landsat-4 scanners and previous scanners are discussed. The simulated Landsat-4 scanner outputs were 3 to 10 percent lower in the red band and 3 to 11 percent higher in the first near-IR band than previous scanners for the soybeans targets. The Landsat-4 scanners were generally more uniform from channel to channel within bands than previous scanners. In the upper-band edge of the red band of the protoflight scanner, one channel was markedly different (12 nm) from the rest. For a soybeans target, this nonuniformity resulted in a within-band difference of 6.2 percent in simulated outputs between channels.
    Keywords: SPACECRAFT INSTRUMENTATION
    Type: International Journal of Remote Sensing (ISSN 0143-1161); 6; 697-716
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...