Publication Date:
2019-07-12
Description:
The magnet parameters of a free-flying version of Astromag and the parameters of the space cryogenic system for the magnet are presented. Consideration is given to the free-flyer version of the Astromag magnet. The diameter of the magnet, its cryostat, the satellite and the two instruments is limited by the 4.27-m shroud diameter of the Atlas IIa. The magnet coil must use a stable reliable superconductor which can carry the full magnet current at 4.2 K at a peak induction in the coil of 7.5 T. The magnet must operate in the persistent mode. The changes in the overall design and operating requirements for the free-flying-design Astromag suggest that the coils, the cryogenic system, and the charging system can be simplified without a loss of required magnet function. Attention is given to switches, trim coils, and plumbing in the low field region between the coils; the magnet charging system and the quench protection system; and cooled helium supply to the magnet gas-cooled electrical leads.
Keywords:
SPACECRAFT DESIGN, TESTING AND PERFORMANCE
Type:
Cryogenics (ISSN 0011-2275); 32; 2 19
Format:
text
Permalink