ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Polymer and Materials Science  (7,845)
  • Life and Medical Sciences  (2,848)
  • ASTROPHYSICS  (2,809)
  • SPACE SCIENCES  (2,036)
Collection
Keywords
Publisher
  • 1
    ISSN: 0197-8462
    Keywords: millimeter-wave radiation ; BHK-21/C13 cells in monolayer culture ; scanning electron microscopy ; transmission electron microscopy ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Both thermal and athermal effects of millimeter-wave radiation on BHK-21/C13 cells were sought using scanning and transmission electron microscopy in conjunction with an in vitro technique that allows direct exposure of monolayer cultures to high average power densities. Culture dishes were irradiated by placing them on the open end of an E- or U-band wave guide. This technique exposes different regions of the cell monolayer lying along the longer axis of the wave guide aperture to varying power densities ranging from zero at each edge to twice the average power density at the center.Cell ultrastructure was unaffected by microwave radiation for 1 hour (41.8 or 74.0 GHz, average power densitites = 320 or 450 mW/cm2, respectively) with or without cooling by rapid recirculation of the culture medium. Temperature in recirculated cultures was held at 37.2 °C, and that in noncooled cultures never exceeded 42 °C during irradiation at either power density. In contrast, cell morphology was affected by microwave exposure whenever irradiation conditions were altered so that the temperature of the monolayer reached or exceeded 44.5 °C. Ultrastructural alterations included breakage of cell processes, progressive detachment of cells from the substrate, increased clumping of heterochromatin in the nuclei, and the appearance of large empty vesicles in the cytoplasm. Such morphological changes resulted from either application of higher average power densities or irradiation at the power densities described above at a higher ambient temperature (〉38.5°C).
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 42 (1991), S. 225-232 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: The micelle-forming monomers of sodium 6-acrylamidocaproate (Na 6-AAC), sodium 11-acrylamidoundecanoate (Na 11-AAU), sodium 11-(N-methylacrylamido) undecanoate (Na 11-MAAU), and sodium 11-(N-ethylacrylamido) undecanoate (Na 11-EAAU) have been synthesized and polymerized. Except poly(Na 6-AAC), the molecular weights of the other three poly(sodium acrylamidoalkanoate) s were over 106. They behave as strong anionic polyelectrolytes in aqueous solutions. Their solution properties, such as viscosity, charge density, and radius of gyration, were investigated. The performance of these anionic polyelectrolytes as coagulant aids in water treatment were assessed by jar test. Poly(Na 6-AAC) and poly (Na 11-AAU) were superior to poly (Na 11-MAAU) and poly (Na 11-EAAU) in terms of flocs settling. All these four anionic polyelectrolytes tested in water treatment are as effective as a commercially available cationic polyamine organic coagulant (Hyperfloc CP 753).
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 6 (1972), S. 59-79 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Advantages of a hollow-fiber hemodialyzer have been well described. The goal of this program was to provide a working model of a noncellulosic hollow fiber artificial kidney with nonthrombogenic blood-contacting surfaces, low blood-priming volume and low pressure drop, a satisfactory rate of urea transport, and high rate of ultrafiltration of water. Also, the reliability and utility of these devices was to be demonstrated through clinical evaluation.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 0021-9541
    Keywords: Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Medicine
    Notes: In this study, the intracellular concentrations of six elements (mmole/kg dry weight) were directly measured in the muscle fibers of pectoralis major muscles of eight week old, genetically dystrophic and normal chickens by the X-ray microanalysis technique. The extent of muscle degeneration was evaluated by morphometric measurements of muscle fiber diameter and other histological changes. A significant increase in the concentration of intracellular sodium and chlorine was evident in dystrophic muscles. The concentration of intracellular sodium was 127.0 ± 35.0 in the muscle fibers of dystrophic chicks compared to 65.7 ± 16.5 in normal controls. The concentration of chlorine was 90.5 ± 27.5 and 54.1 ± 5.5 in the muscle fibers of dystrophic and normal chicks respectively. The intracellular concentrations of potassium, magnesium, phosphorous, and sulfur remained unchanged in the dystrophic condition. Morphometric studies revealed that the dystrophic pectoralis muscles contain fewer but thicker fibers per unit area compared to normal pectoralis muscles. The importance of these findings are discussed in relation to the results of earlier investigations.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 0323-7648
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Description / Table of Contents: Die Copolymerisation von Acrylnitril und Acrylaten wurde in Dimethylformamid bei hohem Acrylnitril/Acrylat-Verhältnis im Temperaturbereich von -50 bis +10°C durch Lithiumalkoxide initiiert. Die Bedingungen zur direkten Präparation von Spinnlösungen der Copolymere wurden erarbeitet. Das Lösungsspinnen dieser Copolymere durch Orientierungsfällung ergab Fasern mit hohen Festigkeitswerten.
    Notes: The copolymerization of acrylonitrile with acrylates has been initiated by lithium alkoxides in dimethylformamide at a high acrylonitrile/acrylate ratio over the temperature range from -50 to 10°C. The conditions for a direct preparation of spinning solutions of the copolymers were determined. The solution-spinning of these copolymers by orientational precipitation yielded fibres exhibiting high strength properties.
    Additional Material: 3 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Acta Polymerica 36 (1985), S. 624-627 
    ISSN: 0323-7648
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Description / Table of Contents: Unter Hernziehung unterschiedlicher Präparationsmethoden wurde die Struktur verdünnter und konzentrierter (0,01 bis 9,8%) Lösungen des starkettigen Polyamidohydrazid (PAH) mittels Elektronenmikroskopie in zwei Lösungsmitteln (DMSO und DMAA) untersucht. Beginnend mit der Konzentration 0,01% erfolgt unterschiedliche Strukturierung in diesen Lösungsmitteln, die bezüglich des Polymers eine unterschiedliche Güte aufweisen. Die Ergebnisse wurden früheren Untersuchungen zur Rheologie konzentrierter PAH-Lösungen in den genannten Lösungsmitteln gegenüber gestellt.
    Notes: The structure of dilute and concentrated solutions (0.01-9.8%) of rigid-chain polyamidohydrazide (PAH) in dimethylsulphoxide and dimethylacetamide was investigated by electron microscopy using various preparation techniques. Starting with a 0.01% concentration, PAH shows two distinct types of structuration in the solvents. The results are compared with previously studied rheological properties of PAH in these solvents.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Publication Date: 2011-08-19
    Description: High-resolution radio images of PKS1830 - 211 are obtained to study the possibility that the double structure is a gravitationally lensed object. The VLBI observations, taken from interferometric radiotelescope networks, reveal an elliptical ring that connects two bright spots of similar composition. Because the lens and the lensed object are closely aligned, and because of the structure of the two spots, the source is concluded to be a radio Einstein ring. The source is found to be close to the galactic plane, and the lens and the lensed object are extragalactic. The source is also found to be unusually bright, suggesting that it is aligned with a bright background source or amplified by some mechanism related to a source that is not so bright.
    Keywords: ASTROPHYSICS
    Type: Nature (ISSN 0028-0836); 352; 132-134
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Publication Date: 2019-06-27
    Description: Performance of Mariner Mars 1969 mission by flight and Earth-based elements during launch and space flight phases - Vol. 2
    Keywords: SPACE SCIENCES
    Type: NASA-CR-117351 , JPL-TR-32-1460-VOL-2
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Publication Date: 2019-06-27
    Description: A rather broad survey is reported of the Venus radar orbiter possibilities within the period 1983-1990. Minimum mission imaging requirements have been set by comparison with the improving capabilities of earth based radar systems and an examination of earth airborne radar imaging. This has led to a requirement for 80 percent coverage at a resolution of 100 m. A first main conclusion is that only the Shuttle-Centaur launch system would be capable of establishing a circular orbit under all possible launch conditions. Thus, orbit eccentricity has been introduced as a parameter throughout this presentation. An examination of typical radar designs has led to upper and lower limits on swath width of 100 and 50 km. A lower eccentricity of 0.2 was set by considering the current Viking propulsion system. An examination of solar perturbations indicates that orbit maintenance problems increase rapidly above an eccentricity of 0.5.
    Keywords: SPACE SCIENCES
    Type: NASA-TM-X-2868 , A-4834
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Publication Date: 2019-08-28
    Description: An evolutionary, gradual, and step-wise spacecraft systems technology development from those used on the Apollos and Skylab 1 to that required for the space station was considered. The four mission spacecraft were dry workshop versions of the Saturn 4-B stage, and each individually configured, outfitted and launched by INT-21 vehicles. These spacecraft were evaluated for crews of three, six and nine men and for mission lifetimes of one year. Two versions of the Apollo CSM, a three man and a four man crew, were considered as the logistic vehicle. The solar cell electrical power system of the first mission evolves into a light weight panel system supplemented by an operating isotope-Brayton system on the later missions. The open life support system of the first mission evolves to a system which recovers both water and oxygen on the last mission. The data handling, communications, radiation shielding, micrometeoroid protection, and orbit keeping systems were determined. The program costs were estimated and, excluding operational costs, the cost for each mission would average about $2 billion of which one-sixth would be for development, one-fourth for experiments, and the balance for vehicle acquisition.
    Keywords: SPACE SCIENCES
    Type: NASA-TM-X-69243 , MS-1
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...