    Keywords: prazosin ; propranolol ; hypertension ; antihypertensive effects ; lipid metabolism ; multicentre study
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary We have carried out randomized 12-week multicentre study to compare the effects of prazosin and propranolol on blood pressure and serum lipids in 70 patients with essential hypertension after a 4 week minimum period of treatment with thiazide diuretics. After 12 weeks treatment with prazosin (n=40, 1.5–12.0 mg per day) or propranolol (n=30, 30–120 mg per day) with diuretics there was a significant blood pressure reduction from 165.1/97.9 mmHg to 151.2/90.6 mmHg and from 167/96.5 mmHg to 153/91.9 mmHg, respectively. In the 12th week a significant decrease was noted in triglyceride and in low-density lipoprotein cholesterol (LDL + VLDL-C), but no significant effects were seen in high-density lipoprotein cholesterol (HDL-C) in patients receiving prazosin. On the other hand, a significant decrease in lecithin cholesterol acyltransferase (LCAT) was seen in patients receiving propranolol. Twenty-six of 40 patients receiving prazosin were given an additional 12 weeks of treatment. Twenty-two of 30 patients initially treated with propranolol were switched from propranolol to prazosin after 13 weeks and given prazosin up to the 24th week. At 24 weeks, the blood pressure was 149/93.0 mmHg in the prazosin group and 155/89.2 mmHg in the group which switched from propranolol to prazosin. Triglyceride remained reduced in the prazosin group at the 24th week. In the group which switched from propranolol to prazosin, triglyceride decreased significantly over the next 12 weeks.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 17 (1980), S. 329-332 
    ISSN: 1432-1041
    Keywords: reserpine ; hydrochlorothiazide ; pituitary hormones ; gonadal hormones ; hypertension ; serum concentration ; antihypertensive therapy
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary Sex histories and serum samples were obtained from 27 hypertensive men before and after 3 months of therapy with either 100 mg of hydrochlorothiazide or 0.25 mg of reserpine daily. Sera were analyzed for testosterone, dihydrotestosterone, estradiol, luteinizing hormone and prolactin. Both drugs effectively lowered blood pressure. The incidence of impaired sexual performance was low and insignificantly different in the two treatment groups. There were no significant changes in serum hormone concentrations as a result of drug therapy.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 2016-06-11
    Description: The lateral distribution of electrons (LDE) of the air showers of size 10 to the 5th power to 10 to the 6th power was studied within one MU. It was found that the LDE of the air showers observed is well represented by NKG function except for vicinity of the core. It was also found that LDE measured by thin scintillators does not differ from that measured by thick ones of 50mm thickness.
    Keywords: SPACE RADIATION
    Type: 19th Intern. Cosmic Ray Conf - Vol. 7; p 107-110; NASA-CP-2376-VOL-7
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Publication Date: 2016-06-11
    Description: Energy per charged particle near the core of air showers was measured by 9 energy flow detectors, which were the combination of Cerenkov counters and scintillators. Energy per particle of each detector was normalized to energy at 2m from the core. The following results were obtained as to the energy flow: (1) integral frequency distribution of mean energy per particle (averaged over 9 detectors) is composed of two groups separated distinctly; and (2) showers contained in one group show an anisotropy of arrival direction.
    Keywords: SPACE RADIATION
    Type: 19th Intern. Cosmic Ray Conf - Vol. 7; p 64-67; NASA-CP-2376-VOL-7
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Publication Date: 2019-06-28
    Description: The longitudinal structure of the air shower disk is studied by measuring the arrival time distributions of air shower particles for showers with electron size in the range 3.2 x 10 to the 5.5. power to 3.2 x 10 to the 7.5 power in the Akeno air-shower array (930 gcm squared atmospheric depth). The average FWHM as a parameter of thickness of air shower disk increases with core distances at less than 50m. AT the present stage, dependence on electron size, zenith angle and air shower age is not apparent. The average thickness of the air shower disk within a core distance of 50m could be determined by an electromagnetic cascade starting from the lower altitude.
    Keywords: SPACE RADIATION
    Type: HE-4.7-2 , 19th Intern. Cosmic Ray Conf - Vol. 7; p 316-319; NASA-CP-2376-VOL-7
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Publication Date: 2019-06-28
    Description: The transition effect of air shower particles in the plastic scintillators near the core was measured by scintillators of various thickness. The air showers selected for the measurement were of 10,000. Results obtained are as follows: (1) the multiplication of shower particles in the scintillators is less than 20% for that of 50 mm thickness; (2) dependence of the transition effect on age parameter is not recognized within the experimental errors.
    Keywords: SPACE RADIATION
    Type: HE-4.4-9 , 19th Intern. Cosmic Ray Conf - Vol. 7; p 179-182; NASA-CP-2376-VOL-7