  • Polymer and Materials Science  (4,682)
  • 1
    ISSN: 0142-2421
    Keywords: SIMS ; GaAs ; round-robin ; sensitivity factor ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: Round-robin studies on relative sensitivity factors (RSFs) in secondary ion mass spectrometry (SIMS) were conducted using bulk GaAs samples uniformly doped with various impurity elements. A total of 31 laboratories participated in two round-robins. More than 30 sets of relative ion intensities were obtained for B, Si, Cr, Mn, Fe, Cu, Zn, In and Te in GaAs. The RSFs for both positive and negative ions were derived for several types of SIMS instruments. The effect of primary ion incident angle was examined using quadrupole-based instruments and found to be the determining factor of the instrumental dependence of RSF. © 1998 John Wiley & Sons, Ltd.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 0142-2421
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: The Japanese VAMAS-SCA working group is composed of 19 institutes. Three kind of Au—Cu alloys (Au 75 at.-%-Cu 25 at.-%, Au 50 at.-%-Cu 50 at.-%, Au 25 at.-%-Cu 75 at.-%) were prepared, and these specimens, pure Au and pure Cu were distributed to the members of the VAMAS-SCA working group. The surface concentrations of these alloys were calculated from the Auger peak amplitudes in two ways. One method used the published relative sensitivity factors, and the other used pure Au and Pure Cu as the standard materials. The mean values of the surface concentrations calculated with the published relative sensitivity factors were almost the same as those calculated with the standard materials. This means that the published relative sensitivity factors are reliable to some extent. The error of the surface concentration calculated with pure Au and pure Cu as the standard materials lay between about 3% and 10%, and that with the relative sensitivity factors lay between about 7% and 20%. The calculated surface concentrations of Au were larger than the bulk concentrations of Au when the matrix effect was neglected.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 24 (1990), S. 331-343 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Glass-ceramic A-W, containing crystalline apatite and wollastonite in a MgO—CaO—SiO2 glassy matrix shows high bioactivity as well as high mechanical strength, but other ceramics containing the same kinds of crystalline phases in different glassy matrices do not show the same bioactivity. In order to investigate the bone-bonding mechanism of this type of glass-ceramic, surface structural changes of the glass-ceramics after exposure to simulated body fluid were analyzed with various techniques. A solution with ion concentrations which are almost equal to those of the human blood plasma was used as the simulated body fluid, instead of Tris-buffer solution hitherto used. For analyzing the surface structural changes, thin-film x-ray diffraction was used in addition to conventional techniques. It was found that a bioactive glass-ceramic forms a Ca, P-rich layer on its surface in the fluid but nonbioactive ones do not, and that the Ca, P-rich layer consists of carbonate-containing hydroxyapatite of small crystallites and/or defective structure. These findings were common to those of Bioglass-type glasses. So, we conclude that the essential condition for glass and glass-ceramic to bond to bone is the formation of the surface apatite layer in the body environment but it is not essential to contain apatite within the material. Bioactivity of glass and glass-ceramic can be evaluated in vitro by examining the formation of the surface apatite layer in the simulated body fluid described above.
    Additional Material: 11 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: A dense, uniform, and highly biologically active bone-like apatite layer can be formed in arbitrary thickness on any kind and shape of solid substrate surface by the following biomimetic method at ordinary temperature and pressure: First, a substrate is set in contact with particles of bioactive CaO—SiO2-based glass soaked in a simulated body fluid (SBF) with inorganic ion concentrations nearly equal to those of human blood plasma so that a number of apatite nuclei are formed on the substrate. Second, the substrate is soaked in another solution with ion concentrations 1.5 times those of SBF (1.5SBF) so that the apatite nuclei grow in situ. In the present study, organic polymer substrates were treated with glow-discharge in O2 gas atmosphere, then subjected to the above-mentioned biomimetic process. The induction periods for the apatite nucleation on all the examined organic polymers were reduced from 24 to 6 h, with glow-discharge treatment. The adhesive strengths of the formed apatite layer to the substrates increased from about 4 to 10 MPa for poly(ethylene terephthalate) and poly-ether sulfone, and from 1 ∼ 2 to 6 ∼ 7 MPa even for poly(methyl methacrylate), polyamide 6 and polyethylene. It is supposed that highly polar groups such as carbonyl, ester, hydroxyl, and carboxyl ones formed by glow-discharge treatment increased the affinity of a silicate ion with the substrates to decrease the induction period, and also increased the affinity of the apatite with the substrate to increase the adhesive strength. The apatite-organic polymer composites thus obtained are expected to be useful as bone-repairing materials as well as soft tissue-repairing materials. © 1995 John Wiley & Sons, Inc.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 0142-2421
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: The Japanese VAMAS-SCA working group is composed of 19 institutes. Three kinds of Au-Cu alloys (Au25 at%-Cu75 at%, Au50 at%-Cu50 at%, Au75 at%-Cu25 at%) were prepared, and these specimens were distributed to the members of Japanese VAMAS-SCA working group and Auger peak amplitude ratios were measured to clarify the correlation factor of different types of spectrometers. The comparison was carried out by using the relative sensitivity factor for Au and Cu. The relative sensitivity factor for lower energy varied from spectrometer to spectrometer, but that for higher energy did not vary so much. Therefore, to carry out the inter-laboratory comparison of the data, the transfer of the data of peak amplitude at higher energy should be recommended.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 0142-2421
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: A matrix effect correction is required to improve the accuracy of quantitative AES analysis. The correction includes terms involving the atomic density (n), electron back-scattering factor (R) and electron escape depth (L). Many schemes have been proposed by various people for corrections of the R and L terms. However, up to now, there have been no systematic investigations of the correction accuracy of the proposed schemes. We have evaluated the correction accuracy, based on measured intensity data for Au—Cu alloys of different compositions. Comparison was made between the observed intensity ratio K (=Iunk/Istd) and the calculated intensity, ratio K′ (= C(nunk/nstd)(Runk/Rstd)(Lunk/Lstd)), where C and I represent the concentration and intensity, respectively. The superscripts ‘unk’ and ‘std’ denote that the parameters are for unknown and standard specimens, here the pure elements. If the correction works well, the error Er (= K′ — K)/(K) will become smaller. Evaluations were carried out on three schemes for the R correction and on seven schemes for the L correction using the Au 239 eV, Au 2024 eV and Cu 920 eV transitions. The root mean square (RMS) of the calculated errors showed several per cent for the best case and 20-30% for the worst case. The RMS error varied a few per cent between schemes for the R correction but it varied ∼30% for the L correction.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 25 (1991), S. 1303-1315 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: It has been proposed that the formation of a surface apatite layer in vivo on surface active ceramics is an essential condition for chemical bonding between ceramics and bone tissue. To clarify the difference in bone-bonding mechanisms between surface active ceramics and bioresorbable ceramics, two experiments were performed using plates of dense β-tricalcium phosphate (β-TCP). First, plates of β-TCP were implanted subcutaneously in rats for 8 weeks. Surface change due to bioresorption was observed with scanning electron microscopy. Formation of the apatite layer on the surface was investigated using thin-film x-ray diffraction and Fourier transform infrared reflection spectroscopy. Second, plates of β-TCP were implanted in tibiae of rabbits for 8 and 25 weeks and subjected to the detaching test to measure bone-bonding strength. β-TCP bonded strongly to bone. Undecalcified sections of the interface of bone and β-TCP were examined with SEM-EPMA. However, by physicochemical methods, no formation of surface apatite layer was observed. These results suggest that β-TCP bonds to bone through microanchoring between bone and rough surface of resorbed β-TCP.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Diaphyseal segmental defects in the tibia of 18 sheep were used to evaluate the healing potential of a composite bone substitute device (CBS) composed of a tricalcium phosphate cylinder (TCP), naturally occurring sheep bone morphogenetic protein (sBMP), and type IV collagen. A total of 100 mg of sBMP and 20 mg of type IV collagen in the high-dose group (CBSH), and 13 mg of sBMP and 2.5 mg of type IV collagen in the low-dose group (CBSL) were adsorbed to TCP cylinders, respectively. TCP cylinders impregnated with type IV collagen alone (TCPC) were used as control. A significantly larger area and more highly integrated intensity of newly formed external callus between CBSH and CBSL or TCPC group were quantified by computerized image analyzer at both 3 and 6 weeks. A torsion test showed that the maximal torque capacity, maximal angular deformation, and bone stiffness of healed osteotomized tibia with implants recovered 117-125% in CBSH, 72-109% in CBSL, and 63-80% in TCPC, compared with the corresponding contralateral tibia at 16 weeks. A healing superiority of the segmental bone defects replaced by the implants was demonstrated in the CBSH group. Thus, the composite bone substitute device defined in this study was shown to possess osteoinductivity, osteoconductivity, and mechanical strength. © 1996 John Wiley & Sons, Inc.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Bognor Regis [u.a.] : Wiley-Blackwell
    Journal of Polymer Science Part B: Polymer Physics 36 (1998), S. 2597-2605 
    ISSN: 0887-6266
    Keywords: positron annihilation ; open space ; relaxation ; subsurface ; polyethylene ; Physics ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: Open spaces in the subsurface region (〈10 μm) of very low density polyethylene were probed by a monoenergetic positron beam. From measurements of Doppler broadening spectra measurements of the annihilation radiation and the lifetime spectra of positrons as a function of incident positron energy, the size of the open spaces in the region of 0-3 μm was found to be larger than that in the deeper region. This was attributed to the cooperative motion of large segments of molecules which is activated near the surface. After the freezing in of such motions (below 230 K), although the lineshape parameter S in the bulk was almost constant, S in the region of 0-3 μm decreased with decreasing temperature. This discrepancy was associated with the presence of the open spaces with an excess content and the resultant contraction of amorphous structure near the surface. © 1998 John Wiley & Sons, Inc. J. Polym. Sci. B Polym. Phys. 36: 2597-2605, 1998
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Polymer Science 28 (1958), S. 450-451 
    ISSN: 0022-3832
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Additional Material: 1 Tab.