ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Polymer and Materials Science  (2)
  • 1
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Electroanalysis 8 (1996), S. 585-590 
    ISSN: 1040-0397
    Keywords: Lipophilic β-cyclodextrin-based ion-selective electrodes ; Local anesthetics ; Tecoflex SG80 ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: 2,3,6-Trioctyl and 2,6-didodecyl-β-cyclodextrins have been incorporated in ion-selective electrodes as neutral ionophores for the detection of the local anesthetics procaine, prilocaine, lidocaine and bupivacaine hydrochlorides. Nernstian response and excellent limits of detection were observed (-log [C]≥5.0). Interference from ‘serum’ levels of sodium, potassium and calcium (150.0 mmol dm-3 Na+, 1.26 mmol dm-3 Ca2+ 4.30 mmol dm-3 K+ ), was negligible (-log Kijpot,) (overall)≥4.0). The major organic interferents were molecules of similar size and structure which caused reduced slope and drift in baseline potentials at 10 mmol dm-3 levels of concentrations. However, the interferences were substantially reduced when the interferent concentration was reduced by a factor of 10. Nernstian response was maintained in the presence of bovine serum albumin (BSA), serum (HS) and aI acid glycoprotein (AAG). A polyurethane, (Tecoflex SG80) membrane matrix was more biocompatible when compared to PVC as evidenced by lower E0 (internal) shifts with the former.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1040-0397
    Keywords: Tricyclic antidepressants ; Cyclodextrin ; Amperometric ; Potentiometric ; Electrocatalysis ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Alkylated α, β and γ cyclodextrins have been incorporated in ion-selective electrodes as neutral ionophores and used for the detection of the tricyclic antidepressants imipramine, desipramine and trimipramine as their hydrochloride salts. Nernstian response and excellent potentiometric limits of detection were observed with each of the three alkylated cyclodextrins examined. Interference from ‘serum’ levels of Na+, K+ and Ca2+ ions was very low. Interference from organic molecules such as glycine, L-histidine and nicotinamide was also low in most cases (see text for exceptions). Electrodes suitable for amperometric measurements were assembled by depositing alkylated cyclodextrins on screen printed electrode substrates. Inclusion of the tricyclic antidepressants in the cyclodextrin cavity aided by controlled potential electrolysis, allowed subnanomolar levels of the analyte to be monitored by square wave voltammetry. Mechanistic studies indicated that, by preconditioning the modified electrodes at approximately +0.6 V in phosphate buffer, the appropriate radical cation was formed, which, on further conditioning at approximately -0.2 V rapidly formed the dimer which possessed a lower oxidation potential of approximately +0.18 V. Monitoring the redox wave at 0.18 V afforded a powerful analytical handle for trace analysis of these tricyclic antidepressants. This redox wave is observable only in the presence of aqueous phosphate which may be attributed to the formation of a hydrogen-bonded surface ion-pair including the substrate and a phosphate counterion.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...