ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 27 (1982), S. 3721-3728 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: The solubility parameter of poly(oxetane), poly(3,3-dimethyloxetane) and poly(3,3-diethyl oxetane) has been estimated by measuring solution viscosities. Values of δ = 9.4, 7.9, and 7.9 cal1/2·cm-3/2 for each polymer were obtained and compared with those calculated from empirical methods. The 3-dimensional solubility parameter approach has been also applied in order to get additional information on the effect of structural modifications on the main chain in the solubility behavior.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Bognor Regis [u.a.] : Wiley-Blackwell
    Journal of Polymer Science Part B: Polymer Physics 33 (1995), S. 1259-1267 
    ISSN: 0887-6266
    Keywords: liquid crystals ; thermotropic polyesters ; relaxations ; phase transitions ; mesophases ; dielectric relaxations ; thermally stimulated depolarization current experiments ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: The relaxation behavior of poly(tetra ethylene oxide terephthaloyl-bis-4-oxybenzoate), PTETOB, was analyzed by thermally stimulated depolarization currents, TSDC, and dynamic mechanical techniques, DMTA, and the results compared with those obtained by differential scanning calcrimetry, thermo-optical analysis, and x-ray diffraction. In the low temperature region, -173-30°C, three main transitions were observed and assigned to the γ relaxation, the glass transition of the mesophase and the glass transition temperature of the amorphous material. The complex behavior observed in the range 110-160°C was as signed to a crystal-crystal transition which competed with the formation of a mesophase and afterward the formation of a smectic A mesophase. At higher temperatures, was observed the transition from the smectic A mesophase to a nematic one, prior to the isotropization temperature. In the TSDC experiments the formation of a permanent electret was detected and the charges trapped in the mesophase were canceled only at the isotropization temperature. © 1995 John Wiley & Sons, Inc.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 34 (1997), S. 157-163 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Hip replacement implants fabricated using the ASTM F-75 alloy sometimes fail in a sudden catastrophic way. In general, fractures start at microstructural defects subjected to stress-corrosion under chemical attack by body fluids. In this paper the results of a study on the effect of casting parameters on the microstructure of ASTM F-75 are presented. The preheating mold temperature and the liquid temperature were varied between 900 and 1000°C, and 1410 and 1470°C, respectively. Optimum static strength and ductility were obtained when shrinkage microporosity and the volume fraction of M23C6 “eutectic” carbides precipitated at grain boundaries were minimized by increasing the preheating mold temperature to 1000°C and by using intermediate pouring temperatures of 1455°C. Under these casting conditions, however, the solidification rates are low, leading to large grain sizes, which, in turn, reduce the strength of the material under dynamic loading conditions. The volume fraction of the M23C6, “blocky” carbides appears to be independent of the casting conditions; however, their size and spatial distributions determine the strength of the as-cast alloys. © 1997 John Wiley & Sons, Inc.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    Surface and Interface Analysis 19 (1992), S. 264-268 
    ISSN: 0142-2421
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: We have recently shown that with the commonly available resolution in Auger electron spectroscopy measurements, significant errors can be incurred in the measured Auger line intensities. To overcome this difficulty, a universal relation has been derived theoretically whereby the experimentally measured line intensities can easily be corrected so as to yield good estimates for the true intensities, i.e. those that would have been measured were the resolution infinitely good. The validity of our correction procedure was recently demonstrated for the high-energy KLL and low-energy LMM lines of Si, Al and Mg as well as for the high-energy LMM and low-energy MNN lines of Cu. In this paper we extend these studies to the high-energy LMM lines of Zn, Ge, Fe, Co and Ni. We present here the intrinsic lineshapes of these lines as well as the Auger sensitivities relative to silver, measured with different resolutions. The correction procedure applied to the data yields the true sensitivities to a good approximation and is therefore important for quantification and for theoretical calculations of Auger Yields.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗