ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 0031-9422
    Keywords: Fusarium culmorum ; biosynthesis ; epoxidation. ; inhibitors ; mycotoxin ; trichothecene
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Biology , Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 0031-9422
    Keywords: Fusarium culmorum ; biosynthesis ; isotrichodiol. ; mycotoxin ; trichothecene
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Biology , Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 0031-9422
    Keywords: Fusarium culmorum ; biosynthesis ; mycotoxin ; trichodiol ; trichothecene ; trichotriol.
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Biology , Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 44 (1992), S. 1321-1330 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Poly(methyl methacrylate) was drawn into fibers by melt extrusion followed immediately by a transient temperature drawing process. By varying five processing variables, fibers ranging from 0.635 mm to 25 μm in diameter were produced. Heat-induced relaxation of the aligned structure was used to determine the draw ratio of the resultant fibers and therefore the degree of polymer chain alignment imposed by the deformation process. The resulting changes in length and diameter were measured and it was found that draw ratios of 5-20 had been achieved under the varying processing conditions. It was also observed that fiber diameter immediately after drawing is a good predictor of the degree of orientation present in the fiber irrespective of the processing conditions. To test the effect molecular orientation has on material properties, fibers with varying degrees of orientation were tested in tension. As expected, increasing alignment resulted in increasing tensile strength. The maximum observed true ultimate tensile strength was 225 ± 53 MPa and was seen in fibers with a draw ratio equal to 18.7 ± 4.5. Fibers with a lower degree of alignment, while not as strong in tension, exhibited significantly increased ductility. True strains of as high as 25% were observed.
    Additional Material: 13 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 33 (1987), S. 2305-2316 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: A simple method is described to obtain rheological data on filled polymeric materials in the form of powders. The powder is compacted in a cylindrical chamber by a plunger driven by the cross-head in an Instron testing machine and the load-displacement curve is recorded. Further information is obtained by compressing the powder to a fixed load and measuring the load decay with time (stress-relaxation). The tests are illustrated by application to “monocomponent toner” powders used in dry copying or nonimpact printing processes. It is shown that compaction and stress-relaxation data are able to differentiate between different toners and facilitate the prediction of their relative performances in terms of pressure fusing. A mechanical spring-dashpot-slider model is effective in describing the rheological behavior of these powders and its dependence on the loading of a hard filler (magnetic pigment). The latter affects the “slider” yield stress in the model but has no influence on the relaxation times.
    Additional Material: 12 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Bognor Regis [u.a.] : Wiley-Blackwell
    Journal of Polymer Science Part B: Polymer Physics 25 (1987), S. 717-722 
    ISSN: 0887-6266
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: We examine the influence of high-energy radiation and subsequent aging and orientation on the degree of crystallinity of poly(vinylidene fluoride) (PVDF) films. In particular, PVDF films were exposed to electron beam radiation (doses up to 50 Mrad) and aged at room temperature for varying lengths of time followed by uniaxial orientation. The degree of crystallinity of these films was found to increase significantly with increasing radiation dose. In addition, a further substantial increase in the degree of crystallinity was observed upon subsequent aging of irradiated films at room temperature. Upon orientation, in addition to a further rise in the degree of crystallinity, the crystallites were observed to undergo the α form → β form transformation, the latter phase being the polar phase effective for piezo-electric/pyroelectric activity.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 25 (1991), S. 295-313 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Recent reports have shown that despite extensive preclinical testing, vascular grafts of biological origin undergo severe biodegradation and aneurysm formation after two or more years of implantation in man. The purpose of this study was to develop a laboratory model to quantitate and correlate the stability of crosslinked collagen grafts in vitro and in vivo. This resistance to biodegradation was assessed by measuring changes in suture pullout force and sample weight in response to controlled digestion with bacterial collagenase, in 0.5-cm-long cylindrical graft segments (chemically processed bovine carotid artery and human umbilical cord vein) that were implanted in the rat subcutis for 2 to 12 weeks. Scar tissue was removed from the explants by brief enzymatic digestion, a process that was inhibited when graft segments had become infected. Changes in dry weight were more consistent than were changes in wet weight; drying the graft segments had no effect on their degradation in vivo or in vitro. Intact cylindrical rings suffered somewhat less damage than did opened, flattened cylinders. Graft degradation increased markedly with implantation time, and was detected after only 3 weeks. We conclude that the rat subcutis model, when combined with controlled enzymatic digestion, first to remove scar tissue and then to challenge structural integrity, provides an accelerated assay by which to predict the stability of collagen vascular grafts.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 26 (1992), S. 829-830 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...