ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Cardiovascular system  (1)
  • Oxygen stores  (1)
  • Polymer and Materials Science  (1)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Journal of comparative physiology 166 (1996), S. 46-54 
    ISSN: 1432-136X
    Keywords: Cardiovascular system ; Chemosensitivity ; Oxygen stores ; Submergence asphyxia ; Aquatic birds
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Notes: Abstract Maximum submergence time of Canada geese was 18% of that of similarly sized Pekin ducks. Due to a smaller respiratory system volume the oxygen store of Canada geese was 82% of that of Pekin ducks, accounting for approximately 33% of the difference in underwater survival times. The respiratory properties and volume of the blood were similar in both species. Both species utilised approximately 79% of the respiratory oxygen store and 90% of the blood oxygen store. Therefore, most of the species difference in survival times was due to a less effective oxygen-conserving cardiovascular response (bradycardia, peripheral vasoconstriction) in Canada geese. Duck cardiac chronotropic sensitivity to hypoxia during submergence was twice that observed in geese. Furthermore, a lower hypoxic ventilatory response was observed in geese than in ducks. Density of monoamine varicosities in hindlimb artery walls was lower in geese than ducks. However, electrical stimulation of the hindlimb muscles did not cause ascending vasodilation during submergence in either species, perhaps due to higher levels of catecholamines in submerged geese. We conclude that the major difference between species is higher oxygen chemosensitivity in ducks which effects a much more rapid and efficacious oxygen-conserving response during forced submergence.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Journal of Polymer Science: Polymer Physics Edition 14 (1976), S. 1111-1119 
    ISSN: 0098-1273
    Keywords: Physics ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: We report flow birefringence observations of polyethylene oxide solutions in a four roll mill where the flow field in the central region of the mill approximates well to that of pure shearing flow. When flow birefringence is observed it is seen to be highly localized within a region close to the “outgoing” asymptotic plane of flow. The phenomenon can be explained in terms of the flow birefringence corresponding to high extension of some polymer chains where the localization is caused by the chains requiring sufficient time in the flow field to become extended. This explanation has important consequences in all “persistently extensional flows” and can explain the origin of previously published results of localized flow birefringence observed for polyethylene solutions in axial compression and axial extensional flows.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...