ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 24 (1986), S. 549-554 
    ISSN: 1741-0444
    Keywords: Finger arterial pressure ; Indirect diastolic pressure ; Photoelectric plethysmography ; Volume oscillometric method
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 24 (1986), S. 585-590 
    ISSN: 1741-0444
    Keywords: Mean capillary pressure ; Microcirculation ; Noninvasive estimation ; Preand postcapillary resistance ratio ; Photoelectric plethysmography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: Abstract A noninvasive method for estimating the mean capillary pressure Pcap and the pre-and postcapillary resistance ratio Rv/Ra in human fingers is described. Volume change in a finger segment was detected with a transmittance-type infra-red photoelectric plethysmograph during a gradual and linear increase in occluding cuff pressure. There was an inflection point in the volume curve which would be produced by the difference in the compliance between the arterial and venous vascular bed in the segment. This transitional point was assumed to represent the complete compression of the venous vascular bed at the cuff pressure level. Thus Pcap was defined as the cuff pressure corresponding to the inflection point. Rv/Ra was calculated from the Pcap, the venous pressure Pv and the mean arterial pressure Pam. The latter two pressures, Pv and Pam, were also indirectly and simultaneously measured by the compression pressure of another cuff and by our new type of volume oscillation method, respectively. The values of Pcap and Rv/Ra were in good agreement with those reported by other investigators.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 27 (1989), S. 130-136 
    ISSN: 1741-0444
    Keywords: Diastolic pressure ; Finger arterial pressure ; Indirect sphygmomanometry ; Photoelectric plethysmography ; Pressure/volume relation ; Vibration method ; Volume oscillometric method
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: Abstract Diastolic pressure Pd was indirectly measured by vibrating a finger artery with a 10 Hz sinusoidal pressure variation during a gradual increase (or decrease) in occlusive cuff pressure Pc. Pulsatile arterial volume changes on which sinusoidal variations are superimposed were detected by a transmitted infra-red photoelectric plethysmograph (TIPP). It is known that volume change in an artery shows a maximum amplitude at the transmural pressure Pt level equal to 0 mm Hg due to the nonlinear viscoelastic properties of the arterial wall. For the same reason, the amplitude of the sinusoidal volume variation reached its maximum at the end-diastolic phase, when Pc was controlled to be exactly equal to Pd. The indirect Pd values determined from Pc were compared with those simultaneously measured by a direct method in rabbit forelegs and by the volume-compensation method in human fingers. Using the principle of the volume oscillometric method systolic and mean pressures were also determined by this system.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...