ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Occupational Health and Environmental Toxicology  (146)
  • Wiley-Blackwell  (146)
  • 1
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 11 (1990), S. 283-296 
    ISSN: 0197-8462
    Keywords: grounding currents ; ELF ; exposure assessment ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: A model is presented that permits the calculation of densities of 60-Hz magnetic fields throughout a residence from only a few measurements. We assume that residential magnetic fields are produced by sources external to the house and by the residential grounding circuit. The field from external sources is measured with a single probe. The field produced by the grounding circuit is calculated from the current flowing in the circuit and its geometry. The two fields are combined to give a prediction of the total field at any point in the house. A data-acquisition system was built to record the magnitude and phase of the grounding current and the field from external sources. The model's predictions were compared with measurements of the total magnetic field at a single location in 23 houses; a correlation coefficient of .87 was obtained, indicating that the model has good predictive capability. A more detailed study that was carried out in one house permitted comparisons of measurements with the model's predictions at locations throughout the house. Again, quite reasonable agreement was found. We also investigated the temporal variability of field readings in this house. Daily magnetic field averages were found to be considerably more stable than hourly averages. Finally, we demonstrate the use of the model in creating a profile of the magnetic fields in a home.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 16 (1995), S. 70-74 
    ISSN: 0197-8462
    Keywords: video display terminals ; embryogenesis ; teratology ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Eighty-nine Swiss Webster mice were randomly divided into four groups: a control group, a pulsed magnetic field (PMF) group, a cytosine arabinoside (ara-C, a teratogen) group, and, a combined PMF + ara-C group. Mice in the PMF and PMF + ara-C groups were irradiated with a PMF (a sawtooth waveform with 52 μs rise time, 12 μs decay time, and 15.6 kHz frequency) at a peak magnetic flux density of 40 μT for 4 hours daily on days 6-17 of gestation. The mice in the ara-C and the PMF + ara-C groups were injected intraperitoneally on day 9 of gestation with 10 mg/kg of ara-C. The incidence of resorption and dead fetuses was not affected by PMF but was increased by ara-C injection. The malformation incidence of cleft palate (CP) and/or cleft lip (CL) was significantly higher in all three of the treated groups than in the control group (P 〈 0.05). If, however, statistical analyses had been done on litters rather than on individual fetuses, they would show that the incidence of CP and/or CL in the PMF group is not significantly greater than that in the control group. A significantly higher incidence of CP and/or CL was found in the PMF + ara-C group (49%) than the ara-C alone group (26.1%). These data suggest that PMF might enhance the development of ara-C-induced CP and/or CL. The incidence of minor variations in skeletal development, including reduction of skeletal calcification and loss of skeleton, was not statistically significant in the PMF group. However, it was higher in the two ara-C-treated groups, and there was no significant difference between the ara-C alone group and the ara-C + PMF group. From these results it is concluded that the very weak embryotoxic effects of PMF exposure may be revealed and enhanced in combination with a teratogenic agent. © 1995 Wiley-Liss, Inc.
    Additional Material: 3 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 15 (1994), S. 53-65 
    ISSN: 0197-8462
    Keywords: intermittents ; transients ; EMF ; electric power ; ground currents ; exposure assessment ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: The current through the residential grounding circuit is an important source for magnetic fields; field variations near the grounding circuit accurately track fluctuations in this ground current. In this paper, a model is presented which permits calculation of the range of these fluctuations. A discrete network model is used to simulate a local distribution system for a single street, and a statistical model to simulate unbalanced currents in the system. Simulations of three-house and ten-house networks show that random appliance operation leads to ground current fluctuations which can be quite large, on the order of 600%. This is consistent with measured fluctuations in an actual house. © 1994 Wiley-Liss, Inc.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 1 (1980), S. 131-147 
    ISSN: 0197-8462
    Keywords: electric fields ; rat ; sciatic nerve ; vagus nerve ; superior cervical sympathetic ganglion ; chronic exposure ; 60 Hz ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Several reports have suggested that the nervous system can be affected by exposure to electric fields and that these effects may have detrimental health consequences for the exposed organism. The purpose of this study was to investigate the effects of chronic (30-day) exposure of rats to a 60-Hz, 100-kV/m electric field on synaptic transmission and peripheral-nerve function. One hundred forty-four rats, housed in individual polycarbonate cages were exposed to uniform, vertical, 60-Hz electric fields in a system free of corona discharge and ozone formation and in which the animals did not receive spark discharges or other shocks during exposure. Following 30 days of exposure to the electric field, superior cervical sympathetic ganglia, vagus and sciatic nerves were removed from rats anesthetized with urethan, placed in a temperature-controlled chamber, and superfused with a modified mammalian Ringer's solution equilibrated with 95% O2 and 5% CO2. Several measures and tests were used to characterize synaptic transmission and peripheral-nerve function. These included amplitude, area, and configuration of the postsynaptic or whole-nerve compound-action potential; conduction velocity; accommodation; refractory period; strength-duration curves; conditioning-test (C-T) response, frequency response; post-tetanic response; and high-frequency-induced fatigue. The results of a series of neurophysiologic tests and measurements indicate that only synaptic transmission is significantly and consistently affected by chronic (30-day) exposure to a 60-Hz, 100-kV/m electric field. Specifically, an increase in synaptic excitability was detected in replicated measurements of the C-T response ratio. In addition, there are trends in other data that can be interpreted to suggest a generalized increase in neuronal excitability in exposed animals.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 2 (1981), S. 371-380 
    ISSN: 0197-8462
    Keywords: electric fields ; 60 Hz ; pineal gland ; circadian rhythm ; melatonin ; 5 methoxytryptophol ; acetyl transferase ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: As a component of studies to search for effects of 60-Hz electric field exposure on mammalian endocrine function, concentrations of melatonin, 5-methoxytryptophol, and serotonin-Nacetyl transferase activity were measured in the pineal glands of rats exposed or sham-exposed at 65 kV/m for 30 days. In two replicate experiments there were statistically significant differences between exposed and control rats in that the normal nocturnal increase in pineal melatonin content was depressed in the exposed animals. Concentrations of 5-methoxytryptophol were increased in the pineal glands of the exposed groups when compared to shamexposed controls. An alteration was also observed in serotonin-N-acetyl transferase activity, with lower levels measured in pineal glands from exposed animals.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 7 (1986), S. 235-237 
    ISSN: 0197-8462
    Keywords: microwaves ; hyperthermia ; chromosome aberration ; sister chromatid exchanges ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Specimens of human blood were exposed to 0, 4, 40, 100, and 200 Wkg-1 of 2.45 GHz microwave radiation for 20 minutes. The blood temperature was carefully controlled so that it rose from 37 to 40°C. Cultured lymphocytes were examined for induced chromosomal damage but no effect in excess of background was observed.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 1 (1980), S. 55-64 
    ISSN: 0197-8462
    Keywords: 60-Hz electric fields ; electrocardiogram (ECG) ; heart rate ; blood pressure ; vascular reactivity ; cold stress ; rats ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Recently, it has been reported that exposure to high-strength electric fields can influence electrocardiogram (ECG) patterns, heart rates, and blood pressures in various species of animals. Our studies were designed to evaluate these reported effects and to help clarify some of the disagreement present in the literature. Various cardiovascular variables were measured in Sprague-Dawley rats exposed or sham-exposed to 60-Hz electric fields at 80 or 100 kV/m for periods up to four months. No significant differences in heart rates, ECG patterns, blood pressures, or vascular reactivity were observed between exposed and sham-exposed rats after 8 hours, 40 hours, 1 month, or 4 months of exposure. Blood pressure and heart rate measurements, made during exposure to a 100-kV/m electric field for one hour, revealed no significant differences between exposed and sham-exposed groups. In addition, physiologic reserve capacity, measured in rats subjected to low temperature after exposure to 100 kV/m for one month, showed that electric-field exposure had no significant effect on physiological response to cold stress. Our studies cannot be directly compared to the work of other investigators because of differences in animal species and electric-field characteristics. However, our failure to detect any cardiovascular changes may have been the result of 1) eliminating secondary field effects such as shocks, audible noise, corona, and ozone; 2) minimizing steady-state microcurrents between the mouth of the animal and watering devices; and 3) minimizing electric-field-induced vibration of the electrodes and animal cages.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 2 (1981), S. 381-390 
    ISSN: 0197-8462
    Keywords: 60-Hz electric fields ; body weight ; oxygen consumption ; rat ; mouse ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: There have been a number of reports in the literature concerning growth-related changes in various animal species exposed to high-strength electric fields. Many of the laboratories reporting such effects have not documented and controlled for the secondary factors that are associated with generating high-strength electric fields (ie, corona, ozone, harmonic distortion, cage vibration, spark discharge). We have designed an exposure system in which we eliminated or minimized these secondary factors, therefore enabling us to examine only the effects of electric fields per se. Sprague-Dawley rats and Swiss-Webster mice were exposed to 60-Hz electric fields at kV/m for up to four months. In 17 individual experiments, we found a greater number of experiments in which the exposed rats had lower body weights than controls. This trend was not evident in data obtained from 14 individual mouse experiments. In more exhaustive growth studies, we found no significant differences in body weights, organ weights, or O2 consumption between exposed and sham-exposed controls. Our failure to detect any major changes in growth was probably the result of eliminating or minimizing the secondary factors associated with electric field exposure.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 16 (1995), S. 48-59 
    ISSN: 0197-8462
    Keywords: electromagnetic fields ; extremely low frequency ; case-control study ; static magnetic field ; magnetic resonance ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: We present a hypothesis that the risk of childhood leukemia is related to exposure to specific combinations of static and extremely-low-frequency (ELF) magnetic fields. Laboratory data from calcium efflux and diatom mobility experiments were used with the gyromagnetic equation to predict combinations of 60 Hz and static magnetic fields hypothesized to enhance leukemia risk. The laboratory data predicted 19 bands of the static field magnitude with a bandwidth of 9.1 μT that, together with 60 Hz magnetic fields, are expected to have biological activity. We then assessed the association between this exposure metric and childhood leukemia using data from a case-control study in Los Angeles County. ELF and static magnetic fields were measured in the bedrooms of 124 cases determined from a tumor registry and 99 controls drawn from friends and random digit dialing. Among these subjects, 26 cases and 20 controls were exposed to static magnetic fields lying in the predicted bands of biological activity centered at 38.0 μT and 50.6 μT. Although no association was found for childhood leukemia in relation to measured ELF or static magnetic fields alone, an increasing trend of leukemia risk with measured ELF fields was found for subjects within these static field bands (P for trend = 0.041). The odds ratio (OR) was 3.3 [95% confidence interval (CI) = 0.4-30.5] for subjects exposed to static fields within the derived bands and to ELF magnetic field above 0.30 μT (compared to subjects exposed to static fields outside the bands and ELF magnetic fields below 0.07 μT). When the 60 Hz magnetic fields were assessed according to the Wertheimer-Leeper code for wiring configurations, leukemia risks were again greater with the hypothesized exposure conditions (OR = 9.2 for very high current configurations within the static field bands: 95% CI = 1.3-64.6). Although the risk estimates are based on limited magnetic field measurements for a small number of subjects, these findings suggest that the risk of childhood leukemia may be related to the combined effects of the static and ELF magnetic fields. Further tests of the hypothesis are proposed. © 1995 Wiley-Liss, Inc.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 16 (1995), S. 119-123 
    ISSN: 0197-8462
    Keywords: EMF ; melatonin ; puberty ; sheep ; transmission line ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: In an earlier study, we found no effects of 60 Hz electric and magnetic fields (EMF) from a 500 kV transmission line on serum melatonin patterns or on puberty in ten female Suffolk lambs (Ovis aries). We conducted a larger replicate study of 15 lambs exposed to a mean electric field of 6.3 kV/m and a mean magnetic field of 3.77 μT and 15 controls exposed to EMF two orders of magnitude weaker than in the line area. The replicate produced essentially the same results as our previous study. © 1995 Wiley-Liss, Inc.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...