ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Occupational Health and Environmental Toxicology  (8)
  • Wiley-Blackwell  (8)
  • American Chemical Society
  • Wiley
  • 1
    ISSN: 0197-8462
    Keywords: magnetic fields ; exposure system ; stray fields ; Merritt coils ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Exposure systems that provide good magnetic field uniformity, minimum stray fields, and minimal heating, vibration, and hum, as well as capability for true sham exposure in which current flows in the coils, are needed to determine rigorously the biological effects of weak magnetic fields. Designs based on acrylic polymer coil support structures and twisted pair bifilary coil windings were employed to fabricate several different systems for the exposure of laboratory animals and cell cultures to magnetic fields. These systems exhibit excellent performance characteristics in terms of exposure field uniformity, stray field containment, and exposure field cancellation in the sham exposure mode. A custom-written computer program was used to determine the best arrangement for coils with regard to field uniformity in the exposure volume and stray field containment. For in vivo exposures, modules were made up of four Merritt four-coil sets, built into a single structure and positioned to form an octapole with fields directed in the horizontal plane. For in vitro applications, two different coil configurations were selected to produce the vertical fields required. A quadrupole system, comprising modules consisting of two Merritt four-coil sets arranged side by side to limit stray fields, was built as a prototype. In the second configuration, one Merritt four-coil set was positioned inside the other to form a concentric coil set. In both in vitro systems, exposure chambers were connected to remote commercial incubators in order to reduce ambient magnetic fields in the exposure volume. An active field cancellation circuit was developed for reducing ambient AC magnetic fields in the in vitro sham exposure chamber, when necessary. These design and fabrication approaches provide systems that offer uniform field exposures and excellent stray field containment when needed and are portable, washable, and relatively inexpensive. © 1994 Wiley-Liss, Inc.This article is a US Government work and, as such, is in the public domain in the United States of America.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 2 (1981), S. 329-340 
    ISSN: 0197-8462
    Keywords: electric fields ; 60 Hz ; biologic effects ; membrane potentials ; recovery ; Pisum sativum ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Roots of Pisum sativum L. were chronically exposed in aqueous inorganic nutrient medium to 60-Hz electric fields between 140 and 490 V/m (growth medium conductivity ∼ 0.08 S/m). The growth rate, meristematic mitotic index, and growth rate recovery of the roots were determined. At 140 V/m there was no perturbation in growth rate or mitotic index. At 430 V/m the growth rate and the mitotic index were reduced. The mitotic index had a maximum depression (∼ 55% of control), which occurred at 4 h. The depression in growth rate was immediate and constant over time. When roots were exposed to an electric field at 430 V/m for 2 days, the growth rate was depressed by about 40%. When the field was terminated, the growth rate steadily increased and was almost normal after 5 days. At 490 V/m root growth rate was almost completely arrested. According to these results, there is a narrow range of induced membrane potentials that span the range from slightly altered to almost completely arrested growth rates.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 4 (1983), S. 21-42 
    ISSN: 0197-8462
    Keywords: biomolecules ; DNA ; microwave absorption ; optical method ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Direct determination of the microwave absorption characteristics of biological molecules in solution by an optical heterodyne technique is described. A visibly transparent sample is irradiated in a spatially nonuniform manner with pulsed microwaves, and the spatial variation in temperature increase measured by detecting the phase chirp impressed on a single-frequency He—Ne laser beam passing through the heated region. Results for several liquids and solutions such as water, methanol, various saline solutions, and solutions of DNA and DNA sodium salt in water are described. Where direct comparison is possible the results agree very well with published values. A significant increase in the absorption of DNA solutions compared with pure water has been observed that is consistent with microwave absorption by the longitudinal mode of the double helix.
    Additional Material: 12 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 5 (1984), S. 147-164 
    ISSN: 0197-8462
    Keywords: DC and 60-Hz magnetic fields ; animal behavior ; memory retention ; locomotor activity ; pentylenetetrazole sezure threshold ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Behavioral measures were evaluated in adult CD-1 and LAF-1 mice continuously exposed for 72 h to a 1.5-Tesla (1 T = 104 Gauss) homogeneous DC magnetic field, and in LAF-1 mice continuously exposed for 72 h to a sinusoidal 60-Hz, 1.65-mT (rms) homogeneous AC field. Three types of behavioral tests were employed: (1) Memory of an electroshock-motivated passive avoidance task was assessed in animals that had been trained immediately prior to the field exposure. The strength of memory was varied either by altering the strength of the electric footshock during training, or by administering a cerebral protein synthesis inhibitor, anisomycin, at the time of training. (2) General locomotor activity was measured using a quadrant-crossing test immediately after termination of the magnetic field exposure. (3) Sensitivity of the experimental subjects to the seizure-inducing neuro-pharmacological agent, pentylenetetrazole, was assessed immediately after the field exposure on the basis of three criteria: (a) the percentage of subjects exhibiting a generalized seizure, (b) the mean time to seizure, and (c) the mean seizure level. The results of these studies revealed no behavioral alterations in exposed mice relative to controls in any of the experimental tests with the 1.5-T DC field or the 60-Hz, 1.65-mT (rms) AC field.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 15 (1994), S. 439-446 
    ISSN: 0197-8462
    Keywords: magnetic field ; electric appliances ; time-weighted average exposure ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Flux density and spectral measurements were carried out on magnetic fields generated by several types of motor-driven personal appliances used near the body. Among the units tested were several for which the average flux densities, as determined at the surfaces of the appliance, exceeded 0.4 mT. Time-rates-of-change (dB/dt) for several units exceeded 1000 T/s, and several units exhibited high-frequency components in the low-MHz range. Use of such appliances, although normally of short duration, can represent exposure to magnetic fields of relatively high flux density, which may also have high-frequency components. Compared to other household and commercial sources of magnetic fields, those generated by certain motor-driven personal appliances may represent a significant contribution to time-weighted average exposure and may represent an important source of local induced currents in the body. Furthermore, high-frequency transients that represent only a minor contribution to time-weighted average exposure may generate significant instantaneous induced currents. © 1994 Wiley-Liss, Inc.This article is a US Government work and, as such, is in the public domain in the United States of America.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 0197-8462
    Keywords: 2450-MHz microwaves ; pulsed and continuous waves ; thermal effects ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Normal human lymphocytes were isolated from the peripheral blood of healthy donors. One-ml samples containing (106) cells in chromosome medium 1A were exposed for 5 days to conventional heating or to continuous wave (CW) or pulsed wave (PW) 2450-MHz radiation at non-heating (37°C) and various heating levels (temperature increases of 0.5, 1.0, 1.5, and 2 °C). The pulsed exposures involved 1-μs pulses at pulse repetition frequencies from 100 to 1,000 pulses per second at the same average SAR levels as the CW exposures. Actual average SARs ranged to 12.3 W/kg. Following termination of the incubation period, spontaneous lymphoblastoid transformation was determined with an image analysis system. The results were compared among each of the experimental conditions and with sham-exposed cultures. At non-heating levels, CW exposure did not affect transformation. At heating levels both conventional and CW heating enhanced transformation to the same extent and correlate with the increases in incubation temperature. PW exposure enhanced transformation at non-heating levels. This finding is significant (P 〈 .002). At heating levels PW exposure enhanced transformation to a greater extent than did conventionalor CW heating. This finding is significant at the .02 level. We conclude that PW 2450-MHz radiation acts differently on the process of lymphoblastoid transformation in vitro compared with CW 2450-MHz radiation at the same average SARs. © 1992 Wiley-Liss, Inc.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 17 (1996), S. 174-179 
    ISSN: 0197-8462
    Keywords: ELF ; electric blanket ; water-bed heater ; magnetic field exposure ; magnetic field dosimetry ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Measurements of the flux density and spectra of magnetic fields (MFs) generated by several types of electric bed heaters (EBH) were made in order to characterize the MFs to which the fetus may be exposed in utero from the mother's use of these devices. Data on MFs were gathered from more than 1,300 in-home and laboratory spot measurements. In-home measurements taken at seven different positions 10 cm from the EBHs determined that the mean flux density at the estimated position of the fetus relative to the device was 0.45 μT (4.5 mG) for electric blankets and 0.20 μT (2.0 mG) for electrically heated water beds. A rate-of-change (RC) metric applied to the nighttime segment of 24 h EMDEX-C personal-dosimeter measurements, which were taken next to the bed of volunteers, yielded an approximate fourfold to sixfold higher value for electric blanket users compared to water-bed heater users. These same data records yielded an approximate twofold difference for the same measurements when evaluated by the time-weighted-average (TWA) MF exposure metric. Performance of exposure meters was checked against standard fields generated in the laboratory, and studies of sources of variance in the in-home measurement protocols were carried out. Spectral measurements showed that the EBH's measured produced no appreciable high-frequency MFs. Data gathered during this work will be used in interpreting results from a component of the California Pregnancy Outcome Study, which evaluates the use of EBHs as a possible risk factor in miscarriage. © 1996 Wiley-Liss, Inc.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 18 (1997), S. 439-445 
    ISSN: 0197-8462
    Keywords: ELF ; magnetic fields ; calcium ; jurkat ; flow-cytometry ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: To explore possible biochemical mechanisms whereby electromagnetic fields of around 0.1 mT might affect immune cells or developing cancer cells, we studied intracellular calcium signaling in the model system Jurkat E6-1 human T-leukemia cells during and following exposure to a 60 Hz magnetic field. Cells were labeled with the intracellular calcium-sensitive fluorescent dye Fluo-3, stimulated with a monoclonal antibody against the cell surface structure CD3 (associated with ligand-stimulated T-cell activation), and analyzed on a FACScan flow-cytometer for increases in intensity of emissions in the range of 515-545 nm. Cells were exposed during or before calcium signal-stimulation to 0.15 mTrms 60 Hz magnetic field. The total DC magnetic field of 78.2 μT was aligned 17.5° off the vertical axis. Experiments used both cells cultured at optimal conditions at 37 °C and cells grown under suboptimal conditions of 24 °C, lowered external calcium, or lowered anti-CD3 concentration. These experiments demonstrate that intracellular signaling in Jurkat E6-1 was not affected by a 60 Hz magnetic field when culture and calcium signal-stimulation were optimal or suboptimal. These results do not exclude field-induced calcium-related effects further down the calcium signaling pathway, such as on calmodulin or other calcium-sensitive enzymes. Bioelectromagnetics 18:439-445, 1997. © 1997 Wiley-Liss, Inc. This article is a US Government work and, as such, is in the public domain in the United States of America.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...