ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • LUNAR AND PLANETARY EXPLORATION  (10)
  • Occupational Health and Environmental Toxicology  (6)
  • 1980-1984  (16)
  • 1
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 4 (1983), S. 397-400 
    ISSN: 0197-8462
    Keywords: acoustical imaging ; microwave-induced acoustics ; pulsed microwaves ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Pulsed 5.66-GHz microwave energy irradiated a model of a human hand that was positioned above a submerged planar array of 400 hydrophones. Hydrophone response data were analyzed by a computer that graphically reproduced the image.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 5 (1984), S. 79-88 
    ISSN: 0197-8462
    Keywords: circular waveguide exposure system ; radiofrequency dosimetry ; rhesus monkey ; radiofrequency exposure ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: A 275-MHz exposure system, consisting of a circular waveguide irradiator and a transparent plastic animal cage, has been developed to accommodate rhesus monkeys weighing up to 15 kg. The vertically oriented waveguide is composed primarily of stainless steel and is fitted with an inner cage fabricated from a tubular section of acrylic plastic. Circularly polarized electromagnetic energy at 275 MHz, either pulsed or continuous wave (CW), can be propagated from the removable top section of the waveguide. The cage is designed to function as the monkey's permanent home. It is fitted with a lever-actuated behavioral performance device on which the monkey responds according to a predetermined schedule to obtain a daily food ration. The system can be adapted to provide for the collection of metabolic and physiologic data as well. Dosimetric measurements were conducted with six rhesus monkeys weighing 3.0-7.2 kg and with a 4-kg model. The dosimetric results show that about one-third of the net incident energy is absorbed by a subject in this system at a normalized specific absorption rate (SAR) of 0.33 (W/kg)/(mW/cm2).
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 3 (1982), S. 385-389 
    ISSN: 0197-8462
    Keywords: electromagnetic dosimetry ; rhesus model dosimetry ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Dosimetric measurements in a 9.5-kg tissue-equivalent rhesus model were conducted at 225 MHz using a nonperturbing temperature probe and a gradient-layer calorimeter. Temperature probe measurements showed deep penetration of electromagnetic energy, and calorimeter experiments showed an average SAR (0.285 W/kg per mW/cm2) that was nearly three times greater than that observed for the same model at 1.29 GHz.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 3 (1982), S. 433-441 
    ISSN: 0197-8462
    Keywords: electromagnetic dosimetry ; microwave absorption ; man-sized model ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Electromagnetic dosimetry was conducted in a tissue-equivalent full-sized model of man irradiated at 2 GHz inside a microwave-anechoic chamber. A nonperturbing temperature probe and a gradient-layer calorimeter were used to determine local and whole-body specific absorption rate (SAR), respectively. Relatively high SAR values were found in the limbs compared to the axis of the trunk of the model. The calorimeter experiments yielded an average SAR about three times higher than that estimated theoretically for a prolate spheroidal model of man. It is suggested that resonant interactions involving the limbs may be responsible for the disparity between theory and experiment.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 1 (1980), S. 149-160 
    ISSN: 0197-8462
    Keywords: microwaves ; microwave dosimetry ; rhesus monkey dosimetry ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Dosimetric measurements were made in a muscle-equivalent model of an adult rhesus monkey subjected to far-field irradiation at 1.29 GHz. Profiles of microwave-induced heating in the model were obtained at eight locations, and a gradient-layer whole-body calorimeter was used to measure total absorbed energy. Average specific absorption rate (SAR) was calculated both from the calorimeter experiments and from the local temperature measurements. Thermographic imaging techniques were used to qualitatively show the microwave-induced surface heating patterns. For this model the calculated average SAR was 0.155 (W/kg)/(mW/cm2) which, at 1.29 GHs, makes the absorption cross section 84% of the geometric shadow cross section. The SAR is about three times that predicted for a prolate spheroidal model of similar mass. A disproportionally high absorption occured in the legs of the model positioned parallel to the E-polarization because of what is believed to be partial-body resonance.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 1 (1980), S. 45-54 
    ISSN: 0197-8462
    Keywords: pulsed microwaves ; thermoelastic waves ; simulated tissue ; hydrophone ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Microwave-induced mechanical stress waves were studied in simulated muscle tissue. Pulsed microwave energy at 5.655 GHz induced pressure waves that were recorded with a hydrophone transducer. Each pulse produced a peak power density greater than 1.5 kW/cm2. Microwave absorption measurements within the model showed energy deposition to be mostly confined to a region within 2 cm of the irradiated surface. The average specific absorption rate (SAR) at the surface of the sample was about 100 W/kg. The microwave-induced stress wave propagated at a velocity of 1,600 m/sec with peak pressures of approximately 300 pascals and was detectable after having traveled a total distance of 0.61 m on a path that included two reflections at model-container interfaces.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Publication Date: 2011-08-18
    Description: Based on a steady-state model of the East Antarctic ice cap, and current estimates of meteorite influx, a model is developed which predicts that the steady-state number of meteorites being carried in or on the ice is at least 760,000. This large meteorite population does not require unusual influx conditions, since the cold, dry climate preserves virtually all meteorites that fall with the exception of the fragile, porous carbonaceous chondrites. Application of the model to the Greenland ice cap yields a steady-state population of about 61,000 meteorites.
    Keywords: LUNAR AND PLANETARY EXPLORATION
    Type: Nature; 292; Aug. 6
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Publication Date: 2011-08-18
    Description: Eleven recent chondrite finds from the Texas Panhandle have been examined and classified according to mineralogical and petrological criteria: five H's, five L's, and one LL chondrite. Five are distinct from nearby finds, while three remain ambiguous and three are related to previously reported chondrites. In addition, data are provided to classify the Muleshoe, Silverton, and Vigo Park chondrites, all of which were previously undescribed in the literature.
    Keywords: LUNAR AND PLANETARY EXPLORATION
    Type: Meteoritics (ISSN 0026-1114); 18; March 31
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Publication Date: 2011-08-18
    Description: Radio astronomical observations of Uranus show that the radio emission spectrum is evolving in time. Ammonia vapor must be depleted in the Uranian atmosphere as Gulkis et al. (1978) previously suggested. Since 1965, ammonia either has been decreasing in time or is a decreasing function of latitude, or both, provided that the radio emission is atmospheric in origin. If Uranus has an observable low-emissivity 'surface', these trends may be reversed. The microwave observations made in 1965, at the time when the spin axis of Uranus was nearly perpendicular to the sun-Uranus line, are consistent with an atmospheric opacity profile that would be produced by saturated ammonia vapor in a predominantly hydrogen atmosphere. At the present time, when the spin axis of Uranus is nearly aligned with the sun-Uranus line, the measurements require an opacity that would be produced by saturated water vapor. A large thermal gradient between the pole and equator is ruled out.
    Keywords: LUNAR AND PLANETARY EXPLORATION
    Type: Science (ISSN 0036-8075); 221; July 29
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Publication Date: 2011-08-18
    Description: The novel calibrations of the Ca-pyroxene thermometer accomplished by Kretz (1982) and Lindsley (1983) are presently applied to 24 analyzed pyroxenes from 24 H6, L6, and LL6 chondrites. Both thermometers indicate that the H group equilibrated to significantly lower temperature (820-830 C) than the L and LL groups, yielding values of 860 C (Lindsley) to 930 C (Kretz).
    Keywords: LUNAR AND PLANETARY EXPLORATION
    Type: Geochimica et Cosmochimica Acta (ISSN 0016-7037); 48; 1363-136
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...