    Il nuovo cimento della Società Italiana di Fisica 2 (1983), S. 255-265 
    ISSN: 0392-6737
    Keywords: Biomagnetism (including magnetocardiography) ; Superconducting devices ; superconducting magnets
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Description / Table of Contents: Riassunto È stata sfruttata la risoluzione spaziale del sensore magnetico per fornire stime numeriche del contributo atriale ai campi magnetici registrati esattamente prima della depolarizzazione ventricolare. Si trova che il contributo è piccolo, e questo rafforza l’interpretazione originale secondo la quale questi campi derivano principalmente dal sistema di conduzione del cuore.
    Notes: Summary We have exploited the spatial resolution of the magnetic sensor to provide numerical estimates of the atrial contribution to magnetic fields recorded just prior to ventricular depolarization. The contribution is found to be small, strenghening our original interpretation that such fields originate mostly in the conduction system of the heart.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Il nuovo cimento della Società Italiana di Fisica 2 (1983), S. 203-213 
    ISSN: 0392-6737
    Keywords: Biomagnetism (including magnetocardiography) ; Superconducting devices ; superconducting magnets
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Description / Table of Contents: Riassunto Si è studiato lo spettro del rumore di un gradiometro superconduttore a derivata secon da in un agglomerato urbano. I dati sono stati ottenuti dal gradiometro con tre accelerometri ortogonali e un magnetometro a flussometro elettronico triassiale attaccato al dewar. Questi dati sono stati analizzati usando tecniche di elaborazione dei segnali, soprattutto un cancellatore adattativo di rumori, per ridurre i rumori nei dati del gradiometro. I risultati mostrano qui che il rumore dell’esterno e/o il rumore del movimento del dewar possono essere ridotti di 40 dB in potenza di rumore. Si è anche mostrato che, nel caso di basso rapporto segnale-rumore (S/N∼1), può essere estratta un’onda sunusoidale di 10 Hz. Questa tecnica non solo promette riduzione dei rumori, ma ha anche lo scopo d’identificare i segnali di rumore che potrebbero essere veramente considerati parte del responso evocato. L’analisi dei dati che contengono i responsi evocati è ora in corso.
    Notes: Summary The noise spectrum of a superconducting second-derivative gradiometer has been investigated in an urban environment. Data have been acquired from the gradiometer with three orthogonal accelerometers and a triaxial fluxgate magnetometer attached to the dewar. These data have been analyzed by using signal processing techniques, primarily an adaptive noise canceller, to reduce noise in the gradiometer data. Results shown here indicate that the environmental noise and/or the dewar motion noise can be reduced as much as 40 dB in noise power. It is also shown, in the case of poor signal-to-noise ratio (S/N∼1), that a 10 Hz sine wave can be extracted. This technique not only shows promise for noise reduction, but also aids in the identification of noise signals which might be misconstrued as part of the evoked response. Analysis of data containing evoked response is now underway.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Il nuovo cimento della Società Italiana di Fisica 2 (1983), S. 184-194 
    ISSN: 0392-6737
    Keywords: Biomagnetism (including magnetocardiography) ; Superconducting devices ; superconducting magnets
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Description / Table of Contents: Riassunto Si è costruito espressamente un sistema SQUID in un ospedale di Parigi, che permette indagini neuromagnetiche attinenti con applicazioni cliniche. Un gradiometro simmetrico di second’ordine lavora entro uno schermo per corrente parassite. Ciò è designato ad ottimizzare il costo e l’efficienza del sistema. Le sue prestazioni sono state sperimentate con dati da pazienti e da soggetti normali.
    Notes: Summary A SQUID system was specially built in a Parisian hospital, allowing neuromagnetic investigations dealing with clinical applications. A second-order symmetrical gradiometer works inside an eddy current shield. This was designed for optimizing the cost and the efficiency of the system. Its performances were tested with data from patients and normal subjects.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Il nuovo cimento della Società Italiana di Fisica 2 (1983), S. 505-511 
    ISSN: 0392-6737
    Keywords: Biomagnetism (including magnetocardiography) ; Superconducting devices ; superconducting magnets
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Description / Table of Contents: Riassunto Si è studiato il campo magnetico prodotto dal cervello prendendo in considerazione una varietà di eventi rari. Si riporta il carattere temporale della risposta a un raro stimolo uditivo. Il campo magnetico appare offrire un’utile nuova sonda dell’attività endogena nel cervello umano.
    Notes: Summary We have studied the magnetic field produced by the brain when attending to a variety of rare events. The temporal character of the response to a rare auditory stimulus is reported. The magnetic field appears to offer a useful new probe of endogeneous activity in the human brain.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Journal of nondestructive evaluation 2 (1981), S. 195-202 
    ISSN: 1573-4862
    Keywords: ac potential difference ; fatigue crack measurement ; slots ; artificial flaws ; parasitic voltages ; NDE
    Source: Springer Online Journal Archives 1860-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Mathematics
    Notes: Abstract The development of a successful and accurate instrument for measuring surface-breaking cracks in metals using the ac field technique has raised several interesting theoretical problems. Measurements with the instrument, known as the Crack Microgauge, do not rely on any prior calibration against an artificial flaw such as a saw-cut in a test block, but some users accustomed to such a calibration from other devices have nevertheless wished to use the instrument in that fashion and have in some instances reported erroneous results. In this paper, we develop a simple theory to explain and quantify this phenomenon. We calculate the parasitic voltages induced in the instrument probe due to the finite opening possessed by an artificial flaw, and we use these results to reinterpret the instrument readings. Controlled experimental measurements on artificial flaws of rectangular cross-section made in aluminum and in steel are found to be in good agreement with the theory. It is shown, however, that application of the theory requires additional information about the internal phase shift associated with the instrument. To enhance the accuracy of the theory, the effect of the corners of the artificial flaws was also considered, although it was not very influential in this work.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Journal of nondestructive evaluation 3 (1982), S. 65-76 
    ISSN: 1573-4862
    Keywords: crack measurement ; ac field technique ; arbitrary skin depth ; NDE
    Source: Springer Online Journal Archives 1860-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Mathematics
    Notes: Abstract A general solution is given to describe the ac field around surface-breaking cracks for arbitrary values of the ratio of skin depth δ to crack depthd. This solution allows accurate interpretation of crack depth from voltage readings taken by a Crack Microgauge instrument in cases where δ andd are comparable. It is shown to agree with asymptotic formulae obtained for the cases where δ/d is very small and very large. Provided that the probe length Δ is large compared with δ, the calculations show that a very good approximation to the crack depth may be obtained, irrespective of the ratio δ/d, by using the thin-skin asymptotic formula $$d = \frac{1}{2}\Delta (V_2 - V_1 )/V_1 $$ whereV 1 andV 2 are probe voltages registered at positions just off and across the crack, respectively. The problem is solved for a crack of infinite aspect ratio which has no opening, but it can be applied with confidence at the centerline of cracks of fairly large aspect ratio.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Journal of nondestructive evaluation 4 (1984), S. 3-12 
    ISSN: 1573-4862
    Keywords: Ultrasonic ; stress measurements ; interfacial stress ; NiTi ; NDE
    Source: Springer Online Journal Archives 1860-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Mathematics
    Notes: Abstract In seeking to develop an NDE technique for verifying the serviceability of NiTi couplers for plumbing unions, it was found that the reflection coefficient for a normally incident ultrasonic wave correlated with the stress level at the NiTi-tubing interface. Current theory pertaining to interface reflection is not complete but, even at present status, there is semiquantitative accord between theoretical predictions and normalized data for reflection coefficient versus stress level. These results are at fixed frequency and with comparable surface roughness. Variation of either frequency or surface roughness further affects the reflection coefficient. Current studies are being pursued to define this effect.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1573-4862
    Keywords: stress fields ; microstructure ; J integral ; stress intensity factor ; harness acoustic velocity ; acoustic elasticity ; NDE
    Source: Springer Online Journal Archives 1860-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Mathematics
    Notes: Abstract A very precise system for measuring two-dimensional velocity fields in solid samples has been used for nondestructive measurements of both externally applied and residual inhomogeneous stresses in solids,J integrals, stress intensity factors of cracks, and hardness of quenched steel. The longitudinal velocity measurement is based on precise determination of the propagation transit time through the stressed solid specimen using a small diameter, water-coupled acoutic transducer, which is scanned mechanically over the sample. Changes in velocity are then related to changes of stress in the sample by the theory of acoustoelasticity. Similar measurements show a high degree of correlation between longitudinal velocity changes and changes in microstructure in steel samples. Applications to problems of solid mechanics and material science illustrate the utility of this nondestructive measuring technique.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    Journal of nondestructive evaluation 2 (1981), S. 65-74 
    ISSN: 1573-4862
    Keywords: NDE ; cast iron ; vibration analysis ; modulus ; strength
    Source: Springer Online Journal Archives 1860-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Mathematics
    Notes: Abstract An outline is given of the existing nondestructive vibration tests for cast irons and their drawbacks in terms of the dimensional accuracy of the components. A proposal is made for a new test based on the change of resonant frequency with vibration amplitude exhibited by cast irons. This proposal is evaluated using material data obtained from dynamic tests of a wide range of cast iron specimens. A test rig is described suitable for testing cylindrical cast bars, and typical results are presented in relation to material strength. There is also a brief description of preliminary testing on cast products.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Springer
    Il nuovo cimento della Società Italiana di Fisica 2 (1983), S. 291-300 
    ISSN: 0392-6737
    Keywords: Biomagnetism (including magnetocardiography) ; Superconducting devices ; superconducting magnets
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Description / Table of Contents: Riassunto Si presentano i risultati preliminari ottenuti costruendo mediante computer mappe di distribuzione di campo magnetico sulla base di registrazioni ad alta risoluzione effettuate con magnetometro superconduttore. La procedura è stata applicata per esaminare i MCG di 16 pazienti affetti da pregresso infarto del miocardio. Sulla base di questa elaborazione è stato possibile dividere i pazienti in due classi, una delle quali contiene tutti i pazienti con depolarizzazioni tardive.
    Notes: Summary A possible clinical application of a high-resolution magnetic isofield contour mapping technique in cardiography is discussed. Preliminary results are presented in applying this technique to patients with recent myocardial infarction. The patients could be divided into two classes; one of them contains patients with electrical late potentials as a subclass.