ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • NDE  (21)
  • Calcium  (20)
  • Gas chromatography  (17)
  • Springer  (58)
  • 2015-2019
  • 1980-1984  (58)
Collection
Publisher
Years
Year
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 32 (1980), S. 45-53 
    ISSN: 1432-0827
    Keywords: Dentin ; Periodicity ; Allometry ; Calcium ; Sulfur
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Summary We have described differences in the aspects of biological rhythms for calcium and sulfur deposition on the labial and lingual sides of the growing rabbit incisor, where growth occurs along a spiral axis. The calcium oscillations appear to be smoother on the labial side than on the lingual side. The lingual side is characterized by high-frequency rhythms with high amplitudes which possess the greatest percent of the power (Fourier analysis). These observations also reflect a difference in behavior of the mean Ca concentration across the labial and lingual sides. Sulfur rhythms on the labial side have higher amplitudes than those on the lingual side, but systematic differences in distribution of power between high and low frequencies is not as pronounced as in the case of Ca. The differences in Ca rhythms reflect differences in the growth rates of incisors on either side of the spiral axis. The labial side grows slightly faster than the lingual side, and its odontoblasts secrete Ca along the spiral axis and toward the pulp cavity at the same time. Thus the resultant direction of growth is more nearly opposite the extension of the occlusal end on the labial side, and Ca is consequently deposited over a wider area relative to that on the lingual surfaces. On the lingual side, Ca is deposited within a more limited area, and growth must therefore be continuous at high frequencies. The distribution of Ca on both sides of the tooth reflects these differences in growth rate and periodicity in two ways. First, given a unit area of tooth, the calcium concentration on the labial side is less than that of the lingual side. Second, whereas the calcium concentration on the labial side declines rapidly from the enamel-dentin junction to the pulp cavity, it is uniformly high across the lingual side because its growth is more continuous at high frequencies.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 32 (1980), S. 29-44 
    ISSN: 1432-0827
    Keywords: Rabbit ; Dentin ; Calcium ; Sulfur ; Periodicity ; Circadian ; Ultradian
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Summary We have identified a variety of biological rhythms involved in the apposition and mineralization of dentin in the rabbit incisor. Animals were injected during the day or night with lead acetate at 2-week intervals—to provide biological time markers in forming dentin—and transverse undecalcified sections of the lower incisors were prepared for electron microprobe analysis. The positions of the lead markers were identified, and the continuous distribution of calcium and sulfur was measured at 1 µm intervals between the markers. In thin sections stained with hematoxylin after decalcification, the widths of a series of structural increments (bands) were measured with an ocular micrometer. Fourier analysis of the data revealed spectra of structural and compositional rhythms with a range of periodicities which extended from a matter of hours [ultradian (〈24 h)] to days [infradian (〉24 h) and circadian (approximately 24 h)]. The structural and compositional rhythms appeared to be independent to the extent that they did not necessarily have the same periods, or amplitudes. Nor were there simple phase relationships between all of the rhythms. At some times, Ca and S fluctuations are inversely proportional (180° out of phase), but in other cases they are directly proportional or out of phase by varying degrees other than 180°. The analyses thus suggest that calcium and sulfur deposition (representing mineral and glycosaminoglycan deposition, respectively) are not simply inversely proportional, and that the hematoxylin-stained structural increments did not solely reflect differences in the distribution of the mineral components in dentin.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Journal of nondestructive evaluation 3 (1982), S. 65-76 
    ISSN: 1573-4862
    Keywords: crack measurement ; ac field technique ; arbitrary skin depth ; NDE
    Source: Springer Online Journal Archives 1860-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Mathematics
    Notes: Abstract A general solution is given to describe the ac field around surface-breaking cracks for arbitrary values of the ratio of skin depth δ to crack depthd. This solution allows accurate interpretation of crack depth from voltage readings taken by a Crack Microgauge instrument in cases where δ andd are comparable. It is shown to agree with asymptotic formulae obtained for the cases where δ/d is very small and very large. Provided that the probe length Δ is large compared with δ, the calculations show that a very good approximation to the crack depth may be obtained, irrespective of the ratio δ/d, by using the thin-skin asymptotic formula $$d = \frac{1}{2}\Delta (V_2 - V_1 )/V_1 $$ whereV 1 andV 2 are probe voltages registered at positions just off and across the crack, respectively. The problem is solved for a crack of infinite aspect ratio which has no opening, but it can be applied with confidence at the centerline of cracks of fairly large aspect ratio.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Journal of nondestructive evaluation 4 (1984), S. 3-12 
    ISSN: 1573-4862
    Keywords: Ultrasonic ; stress measurements ; interfacial stress ; NiTi ; NDE
    Source: Springer Online Journal Archives 1860-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Mathematics
    Notes: Abstract In seeking to develop an NDE technique for verifying the serviceability of NiTi couplers for plumbing unions, it was found that the reflection coefficient for a normally incident ultrasonic wave correlated with the stress level at the NiTi-tubing interface. Current theory pertaining to interface reflection is not complete but, even at present status, there is semiquantitative accord between theoretical predictions and normalized data for reflection coefficient versus stress level. These results are at fixed frequency and with comparable surface roughness. Variation of either frequency or surface roughness further affects the reflection coefficient. Current studies are being pursued to define this effect.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Journal of nondestructive evaluation 2 (1981), S. 195-202 
    ISSN: 1573-4862
    Keywords: ac potential difference ; fatigue crack measurement ; slots ; artificial flaws ; parasitic voltages ; NDE
    Source: Springer Online Journal Archives 1860-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Mathematics
    Notes: Abstract The development of a successful and accurate instrument for measuring surface-breaking cracks in metals using the ac field technique has raised several interesting theoretical problems. Measurements with the instrument, known as the Crack Microgauge, do not rely on any prior calibration against an artificial flaw such as a saw-cut in a test block, but some users accustomed to such a calibration from other devices have nevertheless wished to use the instrument in that fashion and have in some instances reported erroneous results. In this paper, we develop a simple theory to explain and quantify this phenomenon. We calculate the parasitic voltages induced in the instrument probe due to the finite opening possessed by an artificial flaw, and we use these results to reinterpret the instrument readings. Controlled experimental measurements on artificial flaws of rectangular cross-section made in aluminum and in steel are found to be in good agreement with the theory. It is shown, however, that application of the theory requires additional information about the internal phase shift associated with the instrument. To enhance the accuracy of the theory, the effect of the corners of the artificial flaws was also considered, although it was not very influential in this work.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1573-4862
    Keywords: stress fields ; microstructure ; J integral ; stress intensity factor ; harness acoustic velocity ; acoustic elasticity ; NDE
    Source: Springer Online Journal Archives 1860-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Mathematics
    Notes: Abstract A very precise system for measuring two-dimensional velocity fields in solid samples has been used for nondestructive measurements of both externally applied and residual inhomogeneous stresses in solids,J integrals, stress intensity factors of cracks, and hardness of quenched steel. The longitudinal velocity measurement is based on precise determination of the propagation transit time through the stressed solid specimen using a small diameter, water-coupled acoutic transducer, which is scanned mechanically over the sample. Changes in velocity are then related to changes of stress in the sample by the theory of acoustoelasticity. Similar measurements show a high degree of correlation between longitudinal velocity changes and changes in microstructure in steel samples. Applications to problems of solid mechanics and material science illustrate the utility of this nondestructive measuring technique.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Journal of nondestructive evaluation 2 (1981), S. 65-74 
    ISSN: 1573-4862
    Keywords: NDE ; cast iron ; vibration analysis ; modulus ; strength
    Source: Springer Online Journal Archives 1860-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Mathematics
    Notes: Abstract An outline is given of the existing nondestructive vibration tests for cast irons and their drawbacks in terms of the dimensional accuracy of the components. A proposal is made for a new test based on the change of resonant frequency with vibration amplitude exhibited by cast irons. This proposal is evaluated using material data obtained from dynamic tests of a wide range of cast iron specimens. A test rig is described suitable for testing cylindrical cast bars, and typical results are presented in relation to material strength. There is also a brief description of preliminary testing on cast products.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1612-1112
    Keywords: Teflon capillary columns ; Chemically modified teflon ; Gas chromatography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The preparation of teflon capillary columns employing direct coating of the stationary phase to the chemically modified teflon surface and the role of the chemically modified teflon in the separation mechanism are described. Two types of contributions from the modified teflon have been observed: nonspecific adsorption of the carbon surface and specific interactions of polar groups in the carbon skeleton. The use of polar liquid phases can eliminate adsorption due to the presence of polar groups in the modified teflon.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 1615-6102
    Keywords: Calcium ; Contraction ; Discophrya ; Ionophore A23187 ; Ruthenium red ; Tentacles
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology
    Notes: Summary The tentacles of the suctorian protozoonDiscophrya collini are stimulated to contract by externally applied Ca2+. The role of extracellular Ca2+ in tentacle contraction was studied by monitoring45Ca2+ uptake, using ionophore A23187 to facilitate membrane transport of calcium and ruthenium red (RR) as an inhibitor of transport. The degree of tentacle retraction was dependent upon external Ca2+ concentration and studies with45Ca2+ using scintillation counting indicated a linear relationship between external Ca2+ concentration and Ca2+ uptake. Uptake of Ca2+ was enhanced in the presence of the ionophore while RR caused little inhibition.45Ca2+ uptake was only partially inhibited by RR when cells were subjected to a Ca2+, ionophore and RR mixture. Grain counts from light microscope autoradiographs after treatment of cells with45Ca2+/ionophore,45Ca2+/RR or45Ca2+ alone showed heavy, light and intermediate labelling respectively. In all instances the grains were evenly distributed within the cell. These observations are interpreted as supporting the suggestion that the ionophore enhances both the uptake of extracellular Ca2+ and release of Ca2+from an internal source, while the RR could only partially prevent movement of Ca2+ through the plasma mebrane. A model is presented suggesting that tentacle retraction is mediated by cytosolic Ca2+ levels which are determined by the fluxing of Ca2+ across the plasma membrane and the membrane of elongate dense bodies which act as internal Ca2+ reservoirs.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Modified thermal energy analyzer ; Selective detection of nitrogen compounds
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A modification to the TEATM Analyzer is described, which allows it to be used as a highly selective GC detector for nitrogen compounds as well as for N-nitrosamines and nitro compounds. The modified Analyzer is as sensitive as the AFID, but has a much higher selectivity towards nitrogen compounds than the AFID. Its response appears to be molar, with an output that is dependent only on the number of nitrogen atoms present. The performance of the modified Analyzer for the analysis of ammonia, amines,N-nitrosamines, nitriles and organonitro compounds is reported and discussed, as is its application to the detection of these compounds in bacon and beer samples.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...