ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Endothelial cells  (1)
  • Metals and Metallic Materials; Instrumentation and Photography; Chemistry and Materials (General)  (1)
  • 1
    ISSN: 1423-0127
    Keywords: Plasmin ; Calcium influx ; Cytosolic phospholipase A2 ; Endothelial cells
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Notes: Abstract Treatment of cultured bovine carotid artery endothelial cells with 0.1 µM human plasmin has been reported to induce a receptor-mediated short burst of arachidonate release, which is a pertussis toxin-sensitive and extracellular calcium-dependent reaction. Plasmin-induced calcium influx in cells was significantly inhibited by pretreatment with pertussis toxin, indicating that the former was coupled with a pertussis toxin-sensitive guanosine 5′-triphosphate (GTP)-binding protein. Plasmin significantly induced the formation of lysophosphatidylcholine but not lysophosphatidylethanolamine. A cellular phospholipase A2 with an arachidonyl specificity at the sn-2 position of phosphatidylcholine, which required submicromolar calcium, was identified as a cytosolic phospholipase A2 by immunoblot analysis. By a cell-free enzyme activity assay and immunoblot analysis, plasmin was found to induce a translocation of the cytosolic phospholipase A2 from the cytosol to the membrane. Taken together, the results suggest that plasmin bound to its putative receptor and activated a GTP-binding protein coupled to calcium influx channel, followed by translocation and activation of cytosolic phospholipase A2 in endothelial cells.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2019-07-13
    Description: Elemental fractionation during laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) analysis has been historically documented between refractory and volatile elements. In this work, however, we observed fractionation between light rare earth elements (LREEs) and heavy rare earth elements (HREEs) when using ablation strategies involving large spot sizes (greater than 100 millimeters) and line scanning mode. In addition: (1) ion yields decrease when using spot sizes above 100 millimeters; (2) (Eu/Eu*)(sub raw) (i.e. Europium anomaly) positively correlates with carrier gas (He) flow rate, which provides control over the particle size distribution of the aerosol reaching the ICP; (3) (Eu/Eu*)(sub raw) shows a positive correlation with spot size, and (4) the changes in REE signal intensity, induced by the He flow rate change, roughly correlate with REE condensation temperatures. The REE fractionation is likely driven by the slight but significant difference in their condensation temperatures. Large particles may not be completely dissociated in the ICP and result in preferential evaporation of the less refractory LREEs and thus non-stoichiometric particle-ion conversion. This mechanism may also be responsible for Sm-Eu-Gd fractionation as Eu is less refractory than Sm and Gd. The extent of fractionation depends upon the particle size distribution of the aerosol, which in turn is influenced by the laser parameters and matrix. Ablation pits and lines defined by low aspect ratios produce a higher proportion of large particles than high aspect ratio ablation, as confirmed by measurements of particle size distribution in the laser induced aerosol. Therefore, low aspect ratio ablation introduces particles that cannot be decomposed and/or atomized by the ICP and thus results in exacerbated elemental fractionation. Accurate quantification of REE concentrations and Eu/Eu* requires reduction of large particle production during laser ablation. For the reference materials analyzed in this work, the 100 millimeters spot measurements of Eu/Eu* agreed with GeoRem preferred values within 3 percent. Our long-term analyses of Eu/Eu* in MPI-DING glass KL-2G and USGS glass BIR-1G were reproducible at 3 percent (2 RSD).
    Keywords: Metals and Metallic Materials; Instrumentation and Photography; Chemistry and Materials (General)
    Type: GSFC-E-DAA-TN21399 , Journal of Analytical Atomic Spectrometry (e-ISSN 1364-5544); 29; 10; 1835-1843
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...