ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 16 (1995), S. 119-123 
    ISSN: 0197-8462
    Keywords: EMF ; melatonin ; puberty ; sheep ; transmission line ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: In an earlier study, we found no effects of 60 Hz electric and magnetic fields (EMF) from a 500 kV transmission line on serum melatonin patterns or on puberty in ten female Suffolk lambs (Ovis aries). We conducted a larger replicate study of 15 lambs exposed to a mean electric field of 6.3 kV/m and a mean magnetic field of 3.77 μT and 15 controls exposed to EMF two orders of magnitude weaker than in the line area. The replicate produced essentially the same results as our previous study. © 1995 Wiley-Liss, Inc.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2019-07-18
    Description: A theoretical analysis of the behavior of a typical pulse tube regenerator has been carried out. Assuming simple sinusoidal oscillations, the static and oscillatory pressures, velocities and temperatures have been determined for a model that includes a compressible gas and imperfect thermal contact between the gas and the regenerator matrix. For realistic material parameters, the analysis reveals that the pressure and, velocity oscillations are largely independent of details of the thermal contact between the gas and the solid matrix. Only the temperature oscillations depend on this contact. Suggestions for optimizing the design of a regenerator are given.
    Keywords: Mechanical Engineering
    Type: 1995 Cryogenic Engineering Conference; Jul 17, 1995 - Jul 21, 1995; Columbus, OH; United States
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 2019-07-18
    Description: A set of eight non-dimensional scaling parameters for use in evaluating the performance of Pulse Tube Refrigerators is presented. The parameters result after scaling the mass, momentum and energy conservation equations for an axisymmetric, two-dimensional system. The physical interpretation of the parameters are described, and their usefulness is outlined for the enthalpy flow tube (open tube of the pulse tube). The scaling parameters allow the experimentalist to characterize three types of transport: enthalpy flow, mass streaming and heat transfer between the gas and the tube. Also reported are the results from a flow visualization experiment in which steady mass streaming in compressible oscillating flow is observed.
    Keywords: Mechanical Engineering
    Type: Cryogenics Engineering Conference; Jul 17, 1995 - Jul 21, 1995; Columbus, OH; United States
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Publication Date: 2019-07-10
    Description: One-dimensional oscillating flow models are very useful for designing pulse tubes. They are simple to use, not computationally intensive, and the physical relationship between temperature, pressure and mass flow are easy to understand when used in conjunction with phasor diagrams. They do not possess, however, the ability to directly calculate thermal and momentum diffusion in the direction transverse to the oscillating flow. To account for transverse effects, lumped parameter corrections, which are obtained though experiment, must be used. Or two-dimensional solutions of the differential fluid equations must be obtained. A linear two-dimensional solution to the fluid equations has been obtained. The solution provides lumped parameter corrections for one-dimensional models. The model accounts for heat transfer and shear flow between the gas and the tube. The complex Nusselt number and complex shear wall are useful in describing these corrections, with phase relations and amplitudes scaled with the Prandtl and Valensi numbers. The calculated ratio, a, between a two-dimensional solution of the oscillating temperature and velocity and a one-dimensional solution for the same shows a scales linearly with Va for Va less than 30. In this region alpha less than 0.5, that is, the enthalpy flow calculated with a two-dimensional model is 50% of a calculation using a one-dimensional model. For Va greater than 250, alpha = 0.8, showing that diffusion is still important even when it is confined to a thing layer near the tube wall.
    Keywords: Mechanical Engineering
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...