ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Man/System Technology and Life Support; Aerospace Medicine  (1)
  • 1
    Publication Date: 2019-07-13
    Description: Astronauts complete maximal aerobic capacity (VO2pk) testing as part of their annual fitness assessment (AFA) as well as several times once assigned to an International Space Station mission. Historically, the 2-Way T-Shape Non-Rebreathing valve with a mouthpiece and nose clip (Mouthpiece) has been used in these tests. The testing procedure was updated to use the oro-nasal mask (Mask) for the AFA starting in June 2017. Astronauts who used the mask during their AFA requested it be certified to be used for all mission associated tests. Considering the criticality of the data and the schedule constraints of astronauts, it is imperative that the requested hardware change provide data with equivalent reliability and repeatability as provided by the mouthpiece. PURPOSE: To assess the reliability and validity of mask vs. mouthpiece by comparing submaximal and VO2pkdata within subjects (approximately 1 year apart). METHODS: Each of 17 active astronauts completed a VO (sub 2pk) test with the mouthpiece (first) and the mask (second) for their AFA. The VO (sub 2pk) test was conducted on a cycle ergometer with a metabolic cart. The nominal protocol started with a 3-minute warm-up at 50 Watts (W) and increased 25W every minute until volitional fatigue (Light: 45W start; 15W increase). The VO (sub 2pk)s were compared between tests and the expected day-to-day variation (plus or minus 5 percent) was used as the threshold for determining agreement between tests. Submaximal values were plotted and evaluated visually for deviations between mask and mouthpiece. RESULTS: VO (sub 2pk) values were more than 5 percent different, despite similar test times, between mouthpiece and mask in 6 of 17 comparisons, 3 of which were higher with the mask (9.0 plus or minus 5.9 percent) while 3 were lower (minus10.8 plus or minus 2.0 percent) with the mask. The submaximal data did not indicate a leak in either apparatus during these tests. An Astronaut Strength & Conditioning Rehabilitation specialist confirmed that the measured differences in VO (sub 2pk) of these 6 astronauts was consistent with observed changes in exercise habits during the year that separated the two tests. CONCLUSION: After being presented with the results of this data mining effort the mask was accepted for use in all tests, excepting that, if a leak is detected without resolve, the test will be repeated (if schedule allows) and remaining tests will be completed with the mouthpiece.
    Keywords: Man/System Technology and Life Support; Aerospace Medicine
    Type: JSC-E-DAA-TN69156 , American College of Sports Medicine Annual Meeting (ACSM 2019); May 28, 2019 - Jun 01, 2019; Orlando, FL; United States
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...