ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Man/System Technology and Life Support; Aerospace Medicine  (1)
  • 1
    Publication Date: 2019-07-19
    Description: Introduction: Life support technology in large closed systems like submarines and space stations catalyzes carbon monoxide (CO) to carbon dioxide, which is easily removed. However, in a small system like the Extravehicular Mobility Unit (EMU), spacesuit, CO from exogenous (contaminated oxygen (O (sub 2) supply) and endogenous (human metabolism) sources will accumulate in the free suit volume. The free volume becomes a sink for CO that is rebreathed by the astronaut. The accumulation through time depends on many variables: the amount absorbed by the astronaut, the amount produced by the astronaut (between 0.28 and 0.34 moles per hour per kilogram)[1], the amount that enters the suit from contaminated O (sub 2), the amount removed through suit leak, the free volume of the suit, and the O (sub 2) partial pressure[2], just to list a few. Contamination of the EMU O (sub 2) supply with no greater than 1 part per million CO was the motivation for empirical measurements from CO pulse oximetry (SpCO) as well as mathematical modeling of the EMU as a rebreather for CO. Methods: We developed a first-order differential mixing equation as well as an iterative method to compute CO accumulation in the EMU. Pre-post measurements of SpCO (Rad-57, Masimo Corporation) from EMU ground training and on-orbit extravehicular activities (EVAs) were collected. Results: Initial modeling without consideration of the astronaut as a sink but only the source of CO showed that after 8 hours breathing 100 percent O (sub 2) with a 10 milliliter per minute (760 millimeters Hg at 21 degrees Centigrade standard) suit leak, an endogenous production rate of 0.23 moles per hour per kilogram for a 70 kilogram person with 42 liters (1.5 cubic feet) free suit volume resulted in a peak CO partial pressure (pCO) of 0.047 millimeters Hg at 4.3 pounds per square inch absolute (222 millimeters Hg). Preliminary results based on a 2008 model[3] with consideration of the astronaut as a sink and source of CO suggests that most of the rebreathed CO stays bound to hemoglobin and myoglobin and; therefore, pCO only increased to 0.002 millimeters Hg in the EMU. Hemoglobin saturation after 8 hours was an insignificant 0.4 percent compared to about 4 percent for cigarette smokers in the general population. This preliminary modeling result supplements 11 pre-post index finger SpCO measurements from EMU ground training (mean 0.5 percent versus 1 percent, probability equal to 0.41 from paired t-test) and 10 on-orbit pre-post EVAs (mean 1.5 percent versus 1.1 percent, probability equal to 0.17 from paired t-test) that showed no consistent increase, at least no increase outside the accuracy of the oximeter (1 percent display resolution with plus or minus 3 percent Standard Deviation). Discussion: Simulations continue, but a preliminary conclusion is that rebreathing endogenous CO accumulating in the EMU is not a serious medical issue during EVA. The absence of CO poisoning signs or symptoms following hundreds of EVAs is also good empirical evidence that corroborates the limited SpCO measurements and preliminary modeling results.
    Keywords: Man/System Technology and Life Support; Aerospace Medicine
    Type: JSC-CN-34599 , 2016 NASA Human Research Program Investigators'' Workshop; Feb 08, 2016 - Feb 11, 2016; Galveston Island, TX; United States
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...