ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • ELECTRONICS AND ELECTRICAL ENGINEERING  (4)
  • Magnetic stimulation  (3)
  • 1
    Digitale Medien
    Digitale Medien
    Springer
    Annals of biomedical engineering 21 (1993), S. 193-197 
    ISSN: 1573-9686
    Schlagwort(e): Magnetic electroventilation ; Electrically induced inspiration ; Magnetic stimulation ; Electroventilation
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin , Technik allgemein
    Notizen: Abstract Magnetic (eddy-current) stimulation of the inspiratory motor nerves in the neck of the anesthetized dog was achieved. Using a 10-turn coil wound around the base of the neck and a train of pulses (25/s), inspiration was produced by tetanic contraction of the inspiratory muscles. The volume of air inspired increased with an increase in the voltage applied to the capacitor that was discharged repetitively into the coil. In this 10-dog study, the maximum inspired volume was in excess of the spontaneous tidal volume. In a second study, breathing was captured by repeating the stimulus trains at a rate in excess of the spontaneous breathing rate. Oxygen consumption was measured during spontaneous breathing and with captured breathing. The oxygen uptake with magnetic electroventilation was, on the average, 75% higher than with spontaneous breathing. However body temperature did not increase. Although the neck coil was not critical in placement, its field of stimulation was larger than needed to stimulate the phrenic and accessory motor nerves.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    Springer
    Medical & biological engineering & computing 28 (1990), S. 196-198 
    ISSN: 1741-0444
    Schlagwort(e): Magnetic stimulation ; Transchest magnetic cardiac pacing
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Biologie , Chemie und Pharmazie , Medizin
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Digitale Medien
    Digitale Medien
    Springer
    Medical & biological engineering & computing 30 (1992), S. 162-168 
    ISSN: 1741-0444
    Schlagwort(e): Magnetic stimulation ; Transchest magnetic cardiac pacing
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Biologie , Chemie und Pharmazie , Medizin
    Notizen: Abstract Magnetic stimulators, used medically, generate intense rapidly changing magnetic fields, capable of stimulating nerves. Advanced magnetic resonance imaging systems employ stronger and more rapidly changing gradient fields thant those used previously. The risk of provoking cardiac arrhythmias by these new devices is of concern. In the paper, the threshold for cardiac stimulation by an externally-applied magnetic field is determined for 11 anaesthetised dogs. Two coplanar coils provide the pulsed magnetic field. An average energy of approximately 12kJ is required to achieve closed-chest magnetically induced ectopic beats in the 17–26kg dogs. The mean peak induced electric field for threshold stimulation is 213 Vm −1 for a 571 μs damped sine wave pulse. Accounting for waveform efficacy and extrapolating to long-duration pulses, a threshold induced electric field strength of approximately 30 Vm −1 for the rectangular pulse is predicted. It is now possible to establish the margin of safety for devices that use pulsed magnetic fields and to design therapeutic devices employing magnetic fields to stimulate the heart.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    Publikationsdatum: 2019-06-28
    Beschreibung: This report is a technology assessment relevant to the 30 GHz Monolithic Receive Module development. It is based on results obtained on the present NASA Contract (NAS3-23356) as well as on information gathered from literature and other industry sources. To date the on-going Honeywell program has concentrated on demonstrating the so-called interconnected receive module which consists of four monolithic chips - the low noise front-end amplifier (LNA), the five bit phase shifter (PS), the gain control amplifier (GC), and the RF to IF downconverter (RF/IF). Results on all four individual chips have been obtained and interconnection of the first three functions has been accomplished. Future work on this contract is aimed at a higher level of integration, i.e., integration of the first three functions (LNA + PS + GC) on a single GaAs chip. The report presents the status of this technology and projections of its future directions.
    Schlagwort(e): ELECTRONICS AND ELECTRICAL ENGINEERING
    Materialart: NASA-CR-180825 , NAS 1.26:180825
    Format: application/pdf
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 5
    Publikationsdatum: 2019-06-28
    Beschreibung: The design and performance of a GaAs monolithic 180-degree one-bit switched line phase shifter test circuit for Ka-band operation is presented. A self-aligned gate (SAG) fabrication technique is also described that reduces resistive parasitics in the switching FET's. Over the 27.5-30 GHz band, typical measured differential insertion phase is within 10-20 deg of the ideal time delay characteristic. Over the same band, the insertion loss for the SAG phase shifter is about 2.5-3 dB per bit. The SAG fabrication technique holds promise in reducing phase shifter insertion loss to about 1.5 dB/bit for 30-GHz operation.
    Schlagwort(e): ELECTRONICS AND ELECTRICAL ENGINEERING
    Materialart: IEEE Transactions on Microwave Theory and Techniques (ISSN 0018-9480); MTT-31; 1077-108
    Format: text
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 6
    Publikationsdatum: 2019-07-27
    Beschreibung: A monolithic two stage gain control amplifier has been developed using submicron gate length dual gate MESFETs fabricated on ion implanted material. The amplifier has a gain of 12 dB at 30 GHz with a gain control range of over 30 dB. This ion implanted monolithic IC is readily integrable with other phased array receiver functions such as low noise amplifiers and phase shifters.
    Schlagwort(e): ELECTRONICS AND ELECTRICAL ENGINEERING
    Materialart: IEEE, 1987 Microwave and Millimeter-Wave Monolithic Circuits Symposium; June 8 , 9, 1987; Las Vegas, NV; United States
    Format: text
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 7
    facet.materialart.
    Unbekannt
    In:  Other Sources
    Publikationsdatum: 2019-07-12
    Beschreibung: A monolithic gain control amplifier for Ka-band has been developed based on 0.25 micron-gate-length dual-gate FETs fabricated on ion-implanted material. A single-stage monolithic amplifier gives a gain of 6 dB at 31 GHz including fixture losses with a gain control range of over 20 dB. The device and IC design and fabrication are described.
    Schlagwort(e): ELECTRONICS AND ELECTRICAL ENGINEERING
    Materialart: Electronics Letters (ISSN 0013-5194); 22; 503
    Format: text
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...