ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 16 (1995), S. 113-118 
    ISSN: 0197-8462
    Keywords: amino acid ; hyperthermia ; magnetic resonance imaging (MRI) ; microwave ; monoamine ; radiofrequency radiation ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: It is well known that metal objects perturb electromagnetic fields. Therefore, a conventional metal microdialysis probe cannot be used to determine the bioeffects of electromagnetic radiation. Using fused-silica tubing, we developed an inexpensive nonmetallic, rigid microdialysis probe for use in electromagnetic radiation research or during magnetic resonance imaging. This probe has a concentric tube design, with the membrane length adjustable to the size of the area to be dialyzed. The probes tested had regenerated-cellulose membranes that were 3 mm in length. This report describes how to make this probe. Average relative recovery rates at flow rates of 2.0, 1.0, and 0.5 μl/min were 21%, 27%, and 42%, respectively. These rates were slightly lower than the 30%, 42%, and 68% obtained with the commercially available metallic CMA10 microdialysis probe with a 3 mm membrane. This may be due to the fused-silica probe and CMA10 probe being made with different types of dialysis membranes. © 1995 Wiley-Liss, Inc.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 0197-8462
    Keywords: cortex ; electromagnetic fields ; heat stress ; hypothalamus ; thermoregulation ; nonuniform heating ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Nonuniform heating may result from microwave (MW) irradiation of tissues and is therefore important to investigate in terms of health and safety issues. Hypothalamic (Thyp), cortical (Tctx), tympanic (Tty), and rectal (Tre) temperatures were measured in rats exposed in the far field, k-polarization (i.e., head pointed toward the transmitter horn and E-field in vertical direction) to two power densities of 2.06 GHz irradiation. The high-power density (HPM) was 1700 mW/cm2 [specific absorption rate (SAR): hypothalamus 1224 W/kg; cortex 493 W/kg]; the low-power density (LPM) was 170 mW/cm2 (SAR: hypothalamus 122.4 W/kg; cortex 49.3 W/kg). The increase (rate-of-rise, in °C/s) in Thyp was significantly greater than those in Tctx or Tre when rats were exposed to HPM. LPM produced more homogeneous heating. Quantitatively similar results were observed whether rats were implanted with probes in two brain sites or a single probe in one or the other of the two sites. The qualitative difference between regional brain heating was maintained during unrestrained exposure to HPM in the h-polarization (i.e., body parallel to magnetic field). To compare the temperature changes during MW irradiation with those produced by other modalities of heating, rats were immersed in warm water (44 °C, WWI); exposed to a warm ambient environment (50 °C, WSED); or exercised on a treadmill (17 m/min 8% grade) in a warm ambient environment (35 °C, WEX). WWI produced uniform heating in the regions measured. Similar rates-of-rise occurred among regions following WSED or WEX, thus maintaining the pre-existing gradient between Thyp and Tctx. These data indicate that HPM produced a 2-2.5-fold difference in the rate-of-heating within brain regions that were separated by only a few millimeters. In contrast, more homogeneous heating was recorded during LPM or nonmicrowave modalities of heating. Bioelectromagnetics 19:341-353, 1998. © 1998 Wiley-Liss, Inc.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...