ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Analytical Chemistry and Spectroscopy  (99)
  • Physics  (74)
  • Life and Medical Sciences  (45)
  • 1980-1984  (218)
  • 1980  (218)
Collection
Publisher
Years
  • 1980-1984  (218)
Year
  • 1
    ISSN: 1052-9306
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: As part of a study to make a comparative analysis of selected halogenated compounds in man and the environmental media, a quantitative gas chromatographic mass spectrometric analysis of the levels of the halogenated compounds found in the breath, blood and urine of an exposed population (Old Love Canal area, Niagara, New York) and their immediate environment (air and water) was undertaken. In addition, levels of halogenated hydrocarbons in air samples taken in the general Buffalo, Niagara Falls area were determined.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    Journal of Raman Spectroscopy 9 (1980), S. 230-238 
    ISSN: 0377-0486
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: The IR spectra (1400 cm-1 to 160 cm-1) of the gases at ambient temperature and the Raman spectra (below 1400 cm-1) of the liquids near -196°C are reported for CF3OF and CF3OCl. All fundamentals are assigned under Cs symmetry and the results of a normal coordinate analysis are presented. The assignments of Smardzewski and Fox are adopted with one exception for both CF3OF and CF3OCl: the CF3 rock of A″ symmetry is assigned near 430 cm-1 and the two bands between 200 cm-1 and 300 cm-1 are assigned to an A′ fundamental, involving CF3 rocking and COX bending and a Δν=2 transition in the CF3 torsion. An extra band at 548 cm-1 in the Raman spectrum of liquid CF3 COl near -196°C is assigned to a CF3OCl⃛Cl2 complex. The values of the force constants d(OX) for CF3OX molecules are suggested to be near those for X2O molecules. More than half the normal modes of A′ symmetry show extensive mixing of symmetry coordinates. In some of these cases the symmetry coordinate for which the normal mode is named is the largest but not the dominant contributor to the potential energy distribution, while in others this symmetry coordinate is not even the largest contributor to the potential energy distribution. No normal modes of A′ symmetry are present in which ν(CO), δs(CF3), δ(COX), or δ(CF3) symmetry coordinates are dominant, and the mode conventionally labeled as v(CO) should be labeled as νs(CF3). For the remaining A′ normal modes and all the A″ normal modes, the symmetry coordinate for which the normal mode is named is dominant in the potential energy distribution.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Cell Motility and the Cytoskeleton 1 (1980), S. 63-71 
    ISSN: 0886-1544
    Keywords: Physarum polycephalum ; myosin light chains ; polyacrylamide gel electrophoresis ; calcium ; cytoplasmic streaming ; actomyosin ATPase regulation ; Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Medicine
    Notes: Myosin from the slime mold Physarum polycephalum contains three sizes of polypeptides: a heavy chain and two light chains, LC-1 and LC-2. Using a simple qualitative test for calcium binding by comparing electrophoretic migration of the polypeptides in sodium dodecy1 sulfate (SDS) acrylamide gels in the presence and absence of calcium, we have found that Physarum myosin light chain LC-2 migrates with an apparent molecular weight of 16,900 daltons in the presence of the metal ion chelator ethylene glycol bis (B-aminoethyl ether) N,N′-tetraacetic acid (EGTA). However, if calcium chloride is added to the sample prior to electrophoresis, the apparent molecular weight decreases to 16,100. Lanthanide and cadmium ions, but not magnesium, can substitute for calcium. Because the ionic radii of Ca2+, La3+, and Cd2+ are almost identical, we conclude that Physarum myosin LC-2 possesses a very size-specific binding site for calcium. Physarum myosin LC-1 and the heavy chain give no evidence for binding calcium by this test. Since cytoplasmic streaming in the plasmodium of Physarum requires calcium, our evidence indicates that the calcium-binding property of Physarum myosin LC-2 may be important in regulating the production of force by actomyosin in the ectoplasm. Unexpectedly, the myosin light chain in Physarum capable of binding calcium, LC-2, is the essential light chain, while LC-1 is a member of the regulatory class of myosin light chains [V. T. Nachmias, personal communication]. Until now, essential myosin light chains have not been shown to have high affinity divalent cation binding sites. This means a new version of the myosin-based model for actomyosin regulation by calcium may be required to explain cytoplasmic movement in Physarum, and perhaps in other motile systems involving cytoplasmic myosins as well.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Cell Motility and the Cytoskeleton 1 (1980), S. 159-162 
    ISSN: 0886-1544
    Keywords: Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Medicine
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 1 (1980), S. 131-147 
    ISSN: 0197-8462
    Keywords: electric fields ; rat ; sciatic nerve ; vagus nerve ; superior cervical sympathetic ganglion ; chronic exposure ; 60 Hz ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Several reports have suggested that the nervous system can be affected by exposure to electric fields and that these effects may have detrimental health consequences for the exposed organism. The purpose of this study was to investigate the effects of chronic (30-day) exposure of rats to a 60-Hz, 100-kV/m electric field on synaptic transmission and peripheral-nerve function. One hundred forty-four rats, housed in individual polycarbonate cages were exposed to uniform, vertical, 60-Hz electric fields in a system free of corona discharge and ozone formation and in which the animals did not receive spark discharges or other shocks during exposure. Following 30 days of exposure to the electric field, superior cervical sympathetic ganglia, vagus and sciatic nerves were removed from rats anesthetized with urethan, placed in a temperature-controlled chamber, and superfused with a modified mammalian Ringer's solution equilibrated with 95% O2 and 5% CO2. Several measures and tests were used to characterize synaptic transmission and peripheral-nerve function. These included amplitude, area, and configuration of the postsynaptic or whole-nerve compound-action potential; conduction velocity; accommodation; refractory period; strength-duration curves; conditioning-test (C-T) response, frequency response; post-tetanic response; and high-frequency-induced fatigue. The results of a series of neurophysiologic tests and measurements indicate that only synaptic transmission is significantly and consistently affected by chronic (30-day) exposure to a 60-Hz, 100-kV/m electric field. Specifically, an increase in synaptic excitability was detected in replicated measurements of the C-T response ratio. In addition, there are trends in other data that can be interpreted to suggest a generalized increase in neuronal excitability in exposed animals.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 1 (1980), S. 55-64 
    ISSN: 0197-8462
    Keywords: 60-Hz electric fields ; electrocardiogram (ECG) ; heart rate ; blood pressure ; vascular reactivity ; cold stress ; rats ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Recently, it has been reported that exposure to high-strength electric fields can influence electrocardiogram (ECG) patterns, heart rates, and blood pressures in various species of animals. Our studies were designed to evaluate these reported effects and to help clarify some of the disagreement present in the literature. Various cardiovascular variables were measured in Sprague-Dawley rats exposed or sham-exposed to 60-Hz electric fields at 80 or 100 kV/m for periods up to four months. No significant differences in heart rates, ECG patterns, blood pressures, or vascular reactivity were observed between exposed and sham-exposed rats after 8 hours, 40 hours, 1 month, or 4 months of exposure. Blood pressure and heart rate measurements, made during exposure to a 100-kV/m electric field for one hour, revealed no significant differences between exposed and sham-exposed groups. In addition, physiologic reserve capacity, measured in rats subjected to low temperature after exposure to 100 kV/m for one month, showed that electric-field exposure had no significant effect on physiological response to cold stress. Our studies cannot be directly compared to the work of other investigators because of differences in animal species and electric-field characteristics. However, our failure to detect any cardiovascular changes may have been the result of 1) eliminating secondary field effects such as shocks, audible noise, corona, and ozone; 2) minimizing steady-state microcurrents between the mouth of the animal and watering devices; and 3) minimizing electric-field-induced vibration of the electrodes and animal cages.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 0360-6376
    Keywords: Physics ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The plasma polymers formed in glow and nonglow regions of an inductively coupled RF plasma with perfluorobenzene and perfluorocyclohexane are discussed as a function of operating conditions of the plasma by means of ESCA. The core levels of the plasma polymers are shown to be strikingly different but characteristic of a well-defined but complex polymerization scheme. For the nonglow regions fluorine incorporation is shown to be greater than for polymers prepared in the glow regions and a preponderance of CF2 features is apparent. Perfluorobenzene deposits polymer faster than perfluorocyclohexane and changes in component composition of the C1s profile are studied as a function of operating conditions of the gas plasma.
    Additional Material: 13 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 0360-6376
    Keywords: Physics ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The plasma polymers prepared from perfluorocyclohexa-1,3-diene, perfluorocyclohexa-1,4-diene, and perfluorocyclohexene have been investigated by ESCA. The carbon-to-fluorine stoichiometries of the diene-derived polymers are similar and close to that of the starting material. The polymer prepared from perfluorocyclohexene is depleted in fluorine compared to the fluorine content of the “monomer.” The polymers prepared in nonglow regions are also studied and shown to be high in CF2 derived species. The results are compared with those for perfluorobenzene and perfluorocyclohexane, and the polymerization rates are in the order C6F6 〉 C6F8 1,3 ∼ 1,4 〉 C6F10 ∼ C6F12. The variations in composition of the plasma polymer as revealed by ESCA as a function of the polymerization conditions are discussed.
    Additional Material: 14 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Journal of Polymer Science: Polymer Chemistry Edition 18 (1980), S. 3245-3251 
    ISSN: 0360-6376
    Keywords: Physics ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Polypropylene (PP) and polyethylene (PE) peroxy radicals undergo photoreactions, but under commonly encountered photodegradation conditions these reaction rates are much lower than those of conventional radical reactions; for example, for PP peroxy radicals in noon summer sunlight at 25°C their rate of photolysis to alkyl radicals is less than one-tenth of their rate of hydrogen abstraction from the polymer. At lower temperatures( 〈 -10°C) or when more intense radiation is used, however, peroxy radical photolysis becomes a proportionately more important source of alkyl radicals. In addition, occurrence of photoinduced radical combination is confirmed but is shown to be important only when photolysis generates an alkyl radical sufficiently close to a peroxy radical that termination can occur before oxygen reconverts the alkyl radical to a peroxy radical. This termination mechanism therefore becomes more important for radicals generated at lower temperatures when the average separation of a radical pair is lower.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Journal of Polymer Science: Polymer Chemistry Edition 18 (1980), S. 903-911 
    ISSN: 0360-6376
    Keywords: Physics ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: An experimental investigation was conducted to relate the average number of radicals per particle, n̄ to the dimensionless parameter α, as suggested by Stockmayer. Seed emulsion polymerizations of polystyrene were run over a wide range of particle sizes and initiator levels in the 50-70°C temperature range. The seed polymerization technique removed the question of particle formation behavior and allowed a straightforward determination of n̄. Alpha was varied more than three orders of magnitude and resulted in measured values of n̄ in the range 0.5-1.3. These data are in good agreement with Stockmayer's relationship as long as the value of the termination rate constant is taken at the monomer/polymer ratios found in emulsion polymerization. For polystyrene at a monomer/polymer ratio of 60/40 this value is an order of magnitude lower than that found for infinitely dilute polystyrene solutions.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...