ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Publication Date: 2011-08-24
    Description: An analytical solution to the perturbative multiple collision series of a fragmenting HZE ion beam has limited usefulness since the first collision term has several hundred contributions, the second collision term has tens of thousands of contributions, and each successive collision term progresses to unwieldy computational proportions. Our previous work has revealed the multiple collision terms in the straight-ahead approximation to be simple products of a spatially dependent factor times a linear energy-dependent factor of limited domain and unit normalization. The properties of these forms allow the development of the nonperturbative summation of the series to all orders assuming energy-independent nuclear cross sections as matrix products of a scaled Green's function described herein. This nonperturbative Green's function with multiple scattering correction factors compares well with experiments using 670 MeV/u neon-20 ion beams in thick water targets.
    Keywords: Life Sciences (General)
    Type: Radiation research (ISSN 0033-7587); Volume 140; 2; 241-8
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2011-08-24
    Description: Radiation risk cross sections (i.e. risks per particle fluence) are discussed in the context of estimating the risk of radiation-induced cancer on long-term space flights from the galactic cosmic radiation outside the confines of the earth's magnetic field. Such quantities are useful for handling effects not seen after low-LET radiation. Since appropriate cross-section functions for cancer induction for each particle species are not yet available, the conventional quality factor is used as an approximation to obtain numerical results for risks of excess cancer mortality. Risks are obtained for seven of the most radiosensitive organs as determined by the ICRP [stomach, colon, lung, bone marrow (BFO), bladder, esophagus and breast], beneath 10 g/cm2 aluminum shielding at solar minimum. Spectra are obtained for excess relative risk for each cancer per LET interval by calculating the average fluence-LET spectrum for the organ and converting to risk by multiplying by a factor proportional to R gamma L Q(L) before integrating over L, the unrestricted LET. Here R gamma is the risk coefficient for low-LET radiation (excess relative mortality per Sv) for the particular organ in question. The total risks of excess cancer mortality obtained are 1.3 and 1.1% to female and male crew, respectively, for a 1-year exposure at solar minimum. Uncertainties in these values are estimated to range between factors of 4 and 15 and are dominated by the biological uncertainties in the risk coefficients for low-LET radiation and in the LET (or energy) dependence of the risk cross sections (as approximated by the quality factor). The direct substitution of appropriate risk cross sections will eventually circumvent entirely the need to calculate, measure or use absorbed dose, equivalent dose and quality factor for such a high-energy charged-particle environment.
    Keywords: Life Sciences (General)
    Type: Radiation research (ISSN 0033-7587); Volume 141; 1; 57-65
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 2011-08-24
    Description: Errors introduced using a tissue equivalent proportional counter to estimate radiation quality of an arbitrary ion field as related to space radiations are examined. This is accomplished by using a generalized analytic model to calculate the effect of energy loss straggling, track structure, and pathlength distribution on the microdosimetric distribution. The error can be as large as a factor of two, but no systematic trend could be found.
    Keywords: Life Sciences (General)
    Type: Health physics (ISSN 0017-9078); Volume 76; 5; 510-5
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Publication Date: 2011-08-24
    Description: We show the equivalence of semi-classical solutions to optical model coupled-channel equations derived from Watson's form of the nucleus-nucleus multiple-scattering series to the Glauber multiple-scattering series. A second-order solution to the semi-classical coupled-channel elastic amplitude is shown to be nearly equivalent to a second-order optical-phase-shift approximation to the Glauber amplitude if the densities of all nuclear excited states are approximated by the ground-state density. Using the Jastrow method to model the two-body density we find an average excited-state density to be of negligible importance in the double-scattering region of alpha-alpha scattering.
    Keywords: Life Sciences (General)
    Type: Physics letters. [Part B] (ISSN 0370-2693); Volume 223; 2; 127-32
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Publication Date: 2011-08-24
    Description: A tissue equivalent proportional counter designed to measure the linear energy transfer spectra (LET) in the range 0.2-1250 keV/micrometer was flown in the Kvant module on the Mir orbital station during September 1994. The spacecraft was in a 51.65 degrees inclination, elliptical (390 x 402 km) orbit. This is nearly the lower limit of its flight altitude. The total absorbed dose rate measured was 411.3 +/- 4.41 microGy/day with an average quality factor of 2.44. The galactic cosmic radiation (GCR) dose rate was 133.6 microGy/day with a quality factor of 3.35. The trapped radiation belt dose rate was 277.7 microGy/day with an average quality factor of 1.94. The peak rate through the South Atlantic Anomaly was approximately 12 microGy/min and nearly constant from one pass to another. A detailed comparison of the measured LET spectra has been made with radiation transport models. The GCR results are in good agreement with model calculations; however, this is not the case for radiation belt particles and again points to the need for improving the AP8 omni-directional trapped proton models.
    Keywords: Life Sciences (General)
    Type: Radiation measurements (ISSN 1350-4487); Volume 26; 2; 147-58
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Publication Date: 2011-08-24
    Description: We use spatially continuous satellite data as a correlate of precipitation within tropical Africa and show that the majority of documented Ebola hemorrhagic fever outbreaks were closely associated with sharply drier conditions at the end of the rainy season. We propose that these trigger events may enhance transmission of Ebola virus from its cryptic reservoir to humans. These findings suggest specific directions to help understand the sylvatic cycle of the virus and may provide early warning tools to detect possible future outbreaks of this enigmatic disease.
    Keywords: Life Sciences (General)
    Type: The American journal of tropical medicine and hygiene (ISSN 0002-9637); Volume 71; 5; 664-74
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Publication Date: 2011-08-24
    Description: Myoblast cell cultures have been widely employed in conventional (1g) studies of biological processes because characteristics of intact muscle can be readily observed in these cultured cells. We decided to investigate the effects of spaceflight on muscle by utilizing a well characterized myoblast cell line (L8 rat myoblasts) as cultured in the recently designed Space Tissue Loss Flight Module "A" (STL-A). The STL-A is a "state of the art," compact, fully contained, automated cell culture apparatus which replaces a single mid-deck locker on the Space Shuttle. The L8 cells were successfully flown in the STL-A on the Space Shuttle STS-45 mission. Upon return to earth, reculturing of these spaceflown L8 cells (L8SF) resulted in their unexpected failure to fuse and differentiate into myotubes. This inability of the L8SF cells to fuse was found to be a permanent phenotypic alteration. Scanning electron microscopic examination of L8SF cells growing at 1g on fibronectin-coated polypropylene fibers exhibited a strikingly different morphology as compared to control cells. In addition to their failure to fuse into myotubes, L8SF cells also piled up on top of each other. When assayed in fusion-promoting soft agar, L8SF cells gave rise to substantially more and larger colonies than did either preflight (L8AT) or ground control (L8GC) cells. All data to this point indicate that flying L8 rat myoblasts on the Space Shuttle for a duration of 7-10 d at subconfluent densities results in several permanent phenotypic alterations in these cells.
    Keywords: Life Sciences (General)
    Type: Journal of cellular biochemistry (ISSN 0730-2312); Volume 55; 4; 530-44
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Publication Date: 2011-08-24
    Description: A repair/misrepair kinetic model for multiple radiation-induced lesions (mutation inactivation) is coupled to a two-mutation model of initiation-promotion in tissue to provide a parametric description of tumour prevalence in the mouse Harderian gland from high-energy and charge radiations. Track-structure effects are considered using an action-cross section model. Dose-response curves are described for gamma rays and relativistic ions, and good agreement with experiment is found. The effects of nuclear fragmentation are also considered for high-energy proton and alpha-particle exposures. The model described provides a parametric description of age-dependent cancer induction for a wide range of radiation fields. Radiosensitivity parameters found in the model for an initiation mutation (sigma 0 = 7.6 x 10(-10) cm2 and D0 = 148.0 Gy) are somewhat different than previously observed for neoplastic transformation of C3H10T1/2 cell cultures (sigma 0 = 0.7 x 10(-10) cm2 and D0 = 117.0 Gy). We consider the two hypotheses that radiation acts solely as an initiator or as both initiator and promoter and make model calculations for fractionation exposures from gamma rays and relativistic Fe ions. For fractionated Fe exposures, an inverse-dose-rate effect is provided by a promotion hypothesis with an increase of 30% or more, dependent on the dose level and fractionation schedule, using a mutation rate for promotion similar to that of single-gene mutations.
    Keywords: Life Sciences (General)
    Type: Physics in medicine and biology (ISSN 0031-9155); Volume 39; 11; 1811-31
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Publication Date: 2011-08-24
    Description: The production of protons in heavy ion collisions through the knockout mechanism (abrasion) is described using the Glauber model. The multiple knockouts from the projectile, including the inelastic collision series with the target, are considered using a closure approximation in treating energy conservation. Calculations for reactions of 12C projectiles with several targets at energies of 1 and 2A GeV arc compared to experiments. For large secondary proton momentum a strong dependence on the target mass is found and attributed to multiple scattering of the projectile knockouts.
    Keywords: Life Sciences (General)
    Type: Journal of physics. G, Nuclear and particle physics : an Institute of Physics journal (ISSN 0954-3899); Volume 20; 11; 1803-15
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Publication Date: 2011-08-24
    Description: An improved prediction for space radiations in the lower earth orbits measured by the shuttle TEPC is obtained when energy loss straggling and chord length distribution of the detector are considered. A generalized analytic model is used to describe the energy deposition of direct ion interaction events in a micron-size detector. The transport calculation accounting for the shuttle configuration is accomplished by using a new version of HZETRN that has been extensively verified with laboratory and flight data. The agreement of predicted and measured lineal energy spectra is within 70% for the region above 2 keV/micrometer but within a factor of 2.3 underpredicted for the region below this value. The inclusion of indirect delta ray events in the model is needed before possible causes for the underprediction below 2 keV/micrometer can be assessed.
    Keywords: Life Sciences (General)
    Type: Radiation measurements (ISSN 1350-4487); Volume 30; 1; 19-28
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...