ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Life Sciences (General)  (872)
  • 1995-1999  (548)
  • 1990-1994  (310)
  • 1980-1984  (14)
  • 1
    Publication Date: 2011-08-24
    Description: The genus Shewanella has been studied since 1931 with regard to a variety of topics of relevance to both applied and environmental microbiology. Recent years have seen the introduction of a large number of new Shewanella-like isolates, necessitating a coordinated review of the genus. In this work, the phylogenetic relationships among known shewanellae were examined using a battery of morphological, physiological, molecular and chemotaxonomic characterizations. This polyphasic taxonomy takes into account all available phenotypic and genotypic data and integrates them into a consensus classification. Based on information generated from this study and obtained from the literature, a scheme for the identification of Shewanella species has been compiled. Key phenotypic characteristics were sulfur reduction and halophilicity. Fatty acid and quinone profiling were used to impart an additional layer of information. Molecular characterizations employing small-subunit 16S rDNA sequences were at the limits of resolution for the differentiation of species in some cases. As a result, DNA-DNA hybridization and sequence analyses of a more rapidly evolving molecule (gyrB gene) were performed. Species-specific PCR probes were designed for the gyrB gene and used for the rapid screening of closely related strains. With this polyphasic approach, in addition to the ten described Shewanella species, two new species, Shewanella oneidensis and 'Shewanella pealeana', were recognized; Shewanella oneidensis sp. nov. is described here for the first time.
    Keywords: Life Sciences (General)
    Type: International journal of systematic bacteriology (ISSN 0020-7713); Volume 49 Pt 2; 705-24
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2019-07-13
    Description: Apoptosis is a process of cell death characterized by distinctive morphological changes and fragmentation of cellular DNA. Using video imaging and color thresholding techniques, we objectively quantitated the number of cultured CD4+ T-lymphoblastoid cells (HUT78 cells, RH9 subclone) displaying morphological signs of apoptosis before and after exposure to gamma-irradiation. The numbers of apoptotic cells measured by objective video imaging techniques were compared to numbers of apoptotic cells measured in the same samples by sensitive apoptotic assays that quantitate DNA fragmentation. DNA fragmentation assays gave consistently higher values compared with the video imaging assays that measured morphological changes associated with apoptosis. These results suggest that substantial DNA fragmentation can precede or occur in the absence of the morphological changes which are associated with apoptosis in gamma-irradiated RH9 cells.
    Keywords: Life Sciences (General)
    Type: Scanning microscopy (ISSN 0891-7035); 9; 3; 833-42
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 2011-08-24
    Description: Color Doppler images of aortic regurgitation (AR) flow acceleration, flow convergence (FC), and the vena contracta (VC) have been reported to be useful for evaluating severity of AR. However, clinical application of these methods has been limited because of the difficulty in clearly imaging the FC and VC. This study aimed to explore new windows for imaging the FC and VC to evaluate AR volumes in patients and to validate this in animals with chronic AR. Forty patients with AR and 17 hemodynamic states in 4 sheep with strictly quantified AR volumes were evaluated. A Toshiba SSH 380A with a 3.75-MHz transducer was used to image the FC and VC. After routine echo Doppler imaging, patients were repositioned in the right lateral decubitus position, and the FC and VC were imaged from high right parasternal windows. In only 15 of the 40 patients was it possible to image clearly and measure accurately the FC and VC from conventional (left decubitus) apical or parasternal views. In contrast, 31 of 40 patients had clearly imaged FC regions and VCs using the new windows. In patients, AR volumes derived from the FC and VC methods combined with continuous velocity agreed well with each other (r = 0.97, mean difference = -7.9 ml +/- 9.9 ml/beat). In chronic animal model studies, AR volumes derived from both the VC and the FC agreed well with the electromagnetically derived AR volumes (r = 0.92, mean difference = -1.3 +/- 4.0 ml/beat). By imaging from high right parasternal windows in the right decubitus position, complementary use of the FC and VC methods can provide clinically valuable information about AR volumes.
    Keywords: Life Sciences (General)
    Type: The American journal of cardiology (ISSN 0002-9149); Volume 83; 7; 1064-8
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Publication Date: 2011-08-24
    Description: An in-vitro (hydrodynamic) model of the circulatory system was developed. The model consisted of a pump, compliant tubing, and valves for resistance. The model is used to simulate aortic pressure and flow. These parameters were measured using a Konigsburg Pressure transducer and a Triton ART2 flow probe. In addition, venous pressure and flow were measured on the downstream side of the resistance. The system has a known compliance and resistance. Steady and pulsatile flow tests were conducted to determine the resistance of the model. A static compliance test was used to determine the compliance of the system. The aortic pressure and flow obtained from the hydrodynamic model will be used to test the accuracy of parameter estimation models such as the 2-element and 4-element Windkessel models and the 3-element Westkessel model. Verifying analytical models used in determining total peripheral resistance (TPR) and systemic arterial compliance (SAC) is important because it provides insight into hemodynamic parameters that indicate baroreceptor responsiveness to situations such as changes in gravitational acceleration.
    Keywords: Life Sciences (General)
    Type: Biomedical sciences instrumentation (ISSN 0067-8856); Volume 32; 183-8
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Publication Date: 2011-08-24
    Description: Investigative research efforts using a cardiovascular model required the determination of central circulatory haemodynamic and arterial system parameters for the evaluation of cardiovascular performance. These calculations required continuous beat-to-beat measurement of pressure within the four chambers of the heart and great vessels. Sensitivity and offset drift, longevity, and sources of error for eight 3F dual-tipped micromanometers were determined during 21 days of implantation in goats. Subjects were instrumented with pairs of chronically implanted fluid-filled access catheters in the left and right ventricles, through which dual-tipped (test) micromanometers were chronically inserted and single-tip (standard) micromanometers were acutely inserted. Acutely inserted sensors were calibrated daily and measured pressures were compared in vivo to the chronically inserted sensors. Comparison of the pre- and post-gain calibration of the chronically inserted sensors showed a mean sensitivity drift of 1.0 +/- 0.4% (99% confidence, n = 9 sensors) and mean offset drift of 5.0 +/- 1.5 mmHg (99% confidence, n = 9 sensors). Potential sources of error for these drifts were identified, and included measurement system inaccuracies, temperature drift, hydrostatic column gradients, and dynamic pressure changes. Based upon these findings, we determined that these micromanometers may be chronically inserted in high-pressure chambers for up to 17 days with an acceptable error, but should be limited to acute (hours) insertions in low-pressure applications.
    Keywords: Life Sciences (General)
    Type: Medical engineering & physics (ISSN 1350-4533); Volume 20; 6; 410-7
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Publication Date: 2011-08-24
    Description: BACKGROUND: Temporary shunt placement can quickly restore perfusion after extremity arterial injury. This study examined the adequacy of limb blood flow with shunt use, non-heparin-bonded shunt patency over prolonged periods, and the safety of this technique. METHODS: Common iliac arteries were divided and 4.0-mm Silastic Sundt shunts placed in 16 anesthetized pigs. Eight (group I) had shunts placed immediately; eight others (group II) were shunted after an hour of limb ischemia and hemorrhagic shock. Physiologic parameters and femoral artery blood flow in both hindlimbs were continuously monitored. Limb lactic acid generation, oxygen utilization, and hematologic and metabolic effects were serially evaluated for 24 hours. RESULTS: Shunts remained patent in 13 of 16 pigs. Shunts thrombosed in two group I animals because of technical errors, but functioned well after thrombectomy and repositioning. Patency could not be maintained in one animal that died from shock. Flow in group I shunted limbs was 57 (+/-11 SD) % of control. For group II animals in shock, shunted limb flow initially averaged 46 +/- 15% of control, but 4 hours after shunt placement, the mean limb blood flow was the same as in group I. Increased oxygen extraction compensated for the lower flow. Lactic acid production was not increased in comparison to control limbs. CONCLUSION: Shunts provided adequate flow in this model of extremity trauma. Correctly placed shunts stayed patent for 24 hours, without anticoagulation, if shunt placement followed resuscitation.
    Keywords: Life Sciences (General)
    Type: The Journal of trauma (ISSN 0022-5282); Volume 47; 1; 64-71
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Publication Date: 2019-07-13
    Description: BACKGROUND: Data currently available on HIV-1-induced cytopathology is unclear regarding the mechanism of cell killing. OBJECTIVE: To clarify the extent to which apoptosis or necrosis is involved in HIV-1-induced cell death in view of conflicting existing data. METHODS: T lymphoblastoid cells or peripheral blood mononuclear cells were infected by various strains of HIV-1 and the numbers of apoptotic or necrotic cells were quantified at various times after infection using video-image analysis techniques; the results were compared with the amount of fragmented DNA using a quantitative method. Measurement of mitochondrial transmembrane potential (deltapsi(m)) and intracellular calcium concentrations [Ca2+]i was performed with fluorescent probes and fluorescence concentration analysis (FCA). RESULTS: Although lymphoblastoid and monocytoid cells acutely infected by HIV-1 had increased levels of fragmented DNA, a marker of apoptotic cell death, few (〈12%) had condensed chromatin and fragmented nuclei, the morphological features of apoptosis. The predominant alterations in acutely infected cells were distended endoplasmic reticulum and abnormal mitochondria; these ultrastructural changes are consistent with necrosis, although some infected cells simultaneously displayed features of both necrosis and apoptosis. Viability of cells persistently infected by HIV-1 was only minimally reduced from that of uninfected cells. This reduction was accounted for by an increased propensity of the persistently infected cells to die by apoptosis. Alterations in [Ca2+]i and deltapsi(m) occurred in both acutely and persistently infected cells. CONCLUSION: Both necrosis and apoptosis contribute to HIV-1-induced killing of CD4 cells.
    Keywords: Life Sciences (General)
    Type: AIDS (London, England) (ISSN 0269-9370); 13; 14; 1827-39
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Publication Date: 2019-08-16
    Description: Testes from flight rats on COSMOS 2044 and simulated-launch, vivarium, or caudal-elevation control rats (5/group) were analyzed by subjective and quantitative methods. On the basis of observations of fixed tissue, it was evident that some rats had testicular abnormalities unassociated with treatment and probably existing when they were assigned randomly to the four treatment groups. Considering rats without preexisting abnormalities, diameter of seminiferous tubules and numbers of germ cells per tubule cross section were lower (P less than 0.05) in flight than in simulated-launch or vivarium rats. However, ratios of germ cells to each other or to Sertoli cells and number of homogenization-resistant spermatids did not differ from values for simulated-launch or vivarium controls. Expression of testis-specific gene products was not greatly altered by flight. Furthermore, there was no evidence for production of stress-inducible transcripts of the hsp7O or hsp9O genes. Concentration of receptors for rat luteinizing hormone in testicular tissue and surface density of smooth endoplasmic reticulum in Leydig cells were similar in flight and simulated-launch rats. However, concentrations of testosterone in testicular tissue or peripheral blood plasma were reduced (P less than 0.05) in flight rats to less than 20% of values for simulated-launch or vivarium controls. Thus spermatogenesis was essentially normal in flight rats, but production of testosterone was severely depressed. Exposure to microgravity for more than 2 wk might result in additional changes. Sequelae of reduced androgen production associated with microgravity on turnover of muscle and bone should be considered.
    Keywords: Life Sciences (General)
    Type: NASA-CR-204998 , NAS 1.26:204998 , (ISSN 0161-7567); 174S-185S
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Publication Date: 2011-08-24
    Description: We have studied the chemistry, hydroxyapatite crystal size, and maturational changes in bone and dentin from rats exposed to microgravity for 12 days in a Soviet biosatellite (Cosmos 1887). Bone ash was reduced in vertebrae (L5) but not in the non-weight-bearing calvaria or mandibles. All tissues had a relatively normal percentage composition of Ca, P, and Mg. Nevertheless, flight rat calvaria and vertebral tissues tended to exhibit lower Ca/P and higher Ca/Mg ratios that any of their weight-matched controls groups, and gradient density analysis (calvaria) indicated a strong shift to the fractions lower specific gravity that was commensurate with impaired rates of matrix-mineral maturation. X-ray diffraction data were confirmatory. Bone hydroxyapatite crystal growth in the mandibles of flight rats was preferentially altered in such a way as to reduce their size (C-axis dimension). But in the mandibular diastemal region devoid of muscle attachments, flight rat bone and dentin were normal with respect to the Ca, P, Mg, and Zn concentrations and Ca/P and Ca/Mg ratios of age-matched controls. These observations affirm the concept that while microgravity most adversely affects the maturation of newly formed matrix and mineral moieties in weight-bearing bone, such effects occur throughout the skeleton.
    Keywords: Life Sciences (General)
    Type: The FASEB journal : official publication of the Federation of American Societies for Experimental Biology (ISSN 0892-6638); Volume 4; 1; 29-33
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Publication Date: 2011-08-24
    Description: No abstract available
    Keywords: Life Sciences (General)
    Type: Journal of medical and veterinary mycology : bi-monthly publication of the International Society for Human and Animal Mycology (ISSN 0268-1218); Volume 30 Suppl 1; 287-305
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...