ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Life Sciences (General)  (786)
  • 2000-2004  (786)
  • 1
    Publication Date: 2011-08-24
    Description: ALTEA-MICE will supplement the ALTEA project on astronauts and provide information on the functional visual impairment possibly induced by heavy ions during prolonged operations in microgravity. Goals of ALTEA-MICE are: (1) to investigate the effects of heavy ions on the visual system of normal and mutant mice with retinal defects; (2) to define reliable experimental conditions for space research; and (3) to develop animal models to study the physiological consequences of space travels on humans. Remotely controlled mouse setup, applied electrophysiological recording methods, remote particle monitoring, and experimental procedures were developed and tested. The project has proved feasible under laboratory-controlled conditions comparable in important aspects to those of astronauts' exposure to particle in space. Experiments are performed at the Brookhaven National Laboratories [BNL] (Upton, NY, USA) and the Gesellschaft fur Schwerionenforschung mbH [GSI]/Biophysik (Darmstadt, FRG) to identify possible electrophysiological changes and/or activation of protective mechanisms in response to pulsed radiation. Offline data analyses are in progress and observations are still anecdotal. Electrophysiological changes after pulsed radiation are within the limits of spontaneous variability under anesthesia, with only indirect evidence of possible retinal/cortical responses. Immunostaining showed changes (e.g. increased expression of FGF2 protein in the outer nuclear layer) suggesting a retinal stress reaction to high-energy particles of potential relevance in space. c2004 COSPAR. Published by Elsevier Ltd. All rights reserved.
    Keywords: Life Sciences (General)
    Type: Advances in space research : the official journal of the Committee on Space Research (COSPAR); Volume 33; 8; 1347-51
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2011-08-24
    Description: Alteration of metabolism has been suggested as a major limiting factor to long-term space flight. In humans and primates, a negative energy balance has been reported. The metabolic response of rats to space flight has been suggested to result in a negative energy balance. We hypothesized that rats flown in space would maintain energy balance as indicated by maintenance of caloric intake and body mass gain. Further, the metabolism of the rat would be similar to that of laboratory-reared animals. We studied the results from 15 space flights lasting 4 to 19 d. There was no difference in average body weight (206 +/- 13.9 versus 206 +/- 14.8 g), body weight gain (5.8 +/- 0.48 versus 5.9 +/- 0.56 g/d), caloric intake (309 +/- 21.0 versus 309 +/- 20.1 kcal/kg of body mass per day), or water intake (200 +/- 8.6 versus 199 +/- 9.3 mL/kg of body mass per day) between flight and ground control animals. Compared with standard laboratory animals of similar body mass, no differences were noted. The observations suggested that the negative balance observed in humans and non-human primates may be due to other factors in the space-flight environment.
    Keywords: Life Sciences (General)
    Type: Nutrition (Burbank, Los Angeles County, Calif.) (ISSN 0899-9007); Volume 18; 10; 829-36
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 2011-08-24
    Description: The selection, definition, and development phases of a Life Sciences flight research experiment has been consistent throughout the past decade. The implementation process, however, has changed significantly within the past two years. This change is driven primarily by the shift from highly integrated, dedicated research missions on platforms with well defined processes to self contained experiments with stand alone operations on platforms which are being concurrently designed. For experiments manifested on the International Space Station (ISS) and/or on short duration missions, the more modular, streamlined, and independent the individual experiment is, the more likely it is to be successfully implemented before the ISS assembly is completed. During the assembly phase of the ISS, science operations are lower in priority than the construction of the station. After the station has been completed, it is expected that more resources will be available to perform research. The complexity of implementing investigations increases with the logistics needed to perform the experiment. Examples of logistics issues include- hardware unique to the experiment; large up and down mass and volume needs; access to crew and hardware during the ascent or descent phases; maintenance of hardware and supplies with a limited shelf life,- baseline data collection schedules with lengthy sessions or sessions close to the launch or landing; onboard stowage availability, particularly cold stowage; and extensive training where highly proficient skills must be maintained. As the ISS processes become better defined, experiment implementation will meet new challenges due to distributed management, on-orbit resource sharing, and adjustments to crew availability pre- and post-increment. c 2001. Elsevier Science Ltd. All rights reserved.
    Keywords: Life Sciences (General)
    Type: Acta astronautica (ISSN 0094-5765); Volume 49; 3-10; 477-82
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Publication Date: 2011-08-24
    Description: Cellular immune function has been shown to be decreased and latent virus shedding to be increased in human beings isolated during the Antarctic winter, a model used for assessing some effects of space flight. However, the balance of proinflammatory (IFN-gamma) and anti-inflammatory (IL-10 and IL-1RA) cytokines has not previously been evaluated. We therefore sought to determine whether isolation during the Antarctic winter would alter the proinflammatory and anti-inflammatory cytokine balance. Cytokine levels were measured with ELISA in monthly plasma samples from January through September 1999 in 21 study subjects in the Antarctic and 7 control subjects on Macquarie Island. There was a significant time-dependent increase in plasma IFN-gamma (P =.039) as well as decreases in IL-10 (P =.042) and IL-1RA (P =.053) in the study subjects compared with the control subjects. The study subjects also had significantly increased plasma IFN-gamma levels (P 〈 or =.045) but decreased IL-10 and IL-1RA levels (P 〈 or =.036) at individual time points of isolation. Isolation of human beings in the Antarctic appears to shift the plasma cytokine balance toward a proinflammatory profile. These observations are consistent with T-cell activation that might be due to activation of latent viruses, and they could hold importance for determining the risks of space flight.
    Keywords: Life Sciences (General)
    Type: The Journal of allergy and clinical immunology (ISSN 0091-6749); Volume 109; 5; 854-7
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Publication Date: 2011-08-24
    Description: With high-resolution network transmission required for telemedicine, education, and guided-image acquisition, the impact of errors and transmission rates on image quality needs evaluation. METHODS: We transmitted clinical echocardiograms from 2 National Aeronautics and Space Administration (NASA) research centers with the use of Motion Picture Expert Group-2 (MPEG-2) encoding and asynchronous transmission mode (ATM) network protocol over the NASA Research and Education Network. Data rates and network quality (cell losses [CLR], errors [CER], and delay variability [CVD]) were altered and image quality was judged. RESULTS: At speeds of 3 to 5 megabits per second (Mbps), digital images were superior to those on videotape; at 2 Mbps, images were equivalent. Increasing CLR caused occasional, brief pauses. Extreme CER and CDV increases still yielded high-quality images. CONCLUSIONS: Real-time echocardiographic acquisition, guidance, and transmission is feasible with the use of MPEG-2 and ATM with broadcast quality seen above 3 Mbps, even with severe network quality degradation. These techniques can be applied to telemedicine and used for planned echocardiography aboard the International Space Station.
    Keywords: Life Sciences (General)
    Type: Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography (ISSN 0894-7317); Volume 13; 8; 764-70
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Publication Date: 2011-08-24
    Description: BACKGROUND: It has been proposed that exposure to long-term spaceflight conditions (stress, isolation, sleep disruption, containment, microbial contamination, and solar radiation) or to ground-based models of spaceflight will alter human immune responses, but specific antibody responses have not been fully evaluated. OBJECTIVE: We sought to determine whether exposure to the 8-month Antarctic winter-over model of spaceflight would alter human antibody responses. METHODS: During the 1999 Australian National Antarctic Research Expeditions, 11 adult study subjects at Casey, Antarctica, and 7 control subjects at Macquarie Island, sub-Antarctica, received primary and secondary immunizations with the T cell-dependent neoantigen bacteriophage phi X-174. Periodic plasma samples were analyzed for specific antibody function. RESULTS: All of the subjects from Casey, Antarctica, cleared bacteriophage phi X-174 normally by 1 week after primary immunization, and all had normal primary and secondary antibody responses, including immunologic memory amplification and switch from IgM to IgG antibody production. One subject showed a high normal pattern, and one subject had a low normal pattern. The control subjects from Macquarie Island also had normal immune responses to bacteriophage phi X-174. CONCLUSIONS: These data do not support the hypothesis that de novo specific antibody responses of subjects become defective during the conditions of the Antarctic winter-over. Because the Antarctic winter-over model of spaceflight lacks the important factors of microgravity and solar radiation, caution must be used in interpreting these data to anticipate normal antibody responses in long-term spaceflight.
    Keywords: Life Sciences (General)
    Type: The Journal of allergy and clinical immunology (ISSN 0091-6749); Volume 107; 1; 160-4
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Publication Date: 2011-08-24
    Description: Plant culture in oxygen concentrations below ambient is known to stimulate vegetative growth, but apart from reports on increased leaf number and weight, little is known about development at subambient oxygen concentrations. Arabidopsis thaliana (L.) Heynh. (cv. Columbia) plants were grown full term in pre-mixed atmospheres with oxygen partial pressures of 2.5, 5.1, 10.1, 16.2, and 21.3 kPa O2, 0.035 kPa CO2 and the balance nitrogen under continuous light. Fully expanded leaves were harvested and processed for light and transmission electron microscopy or for starch quantification. Growth in subambient oxygen concentrations caused changes in leaf anatomy (increased thickness, stomatal density and starch content) that have also been described for plants grown under carbon dioxide enrichment. However, at the lowest oxygen treatment (2.5 kPa), developmental changes occurred that could not be explained by changes in carbon budget caused by suppressed photorespiration, resulting in very thick leaves and a dwarf morphology. This study establishes the leaf parameters that change during growth under low O2, and identifies the lower concentration at which O2 limitation on transport and biosynthetic pathways detrimentally affects leaf development. Grant numbers: NAG5-3756, NAG2-1020, NAG2-1375.
    Keywords: Life Sciences (General)
    Type: Plant, cell & environment (ISSN 0140-7791); Volume 24; 4; 419-28
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Publication Date: 2019-07-13
    Description: OBJECTIVES: This study was conducted to evaluate follow-up results in patients with hypertrophic obstructive cardiomyopathy (HOCM) who underwent either percutaneous transluminal septal myocardial ablation (PTSMA) or septal myectomy. BACKGROUND: Controversy exists with regard to these two forms of treatment for patients with HOCM. METHODS: Of 51 patients with HOCM treated, 25 were treated by PTSMA and 26 patients via myectomy. Two-dimensional echocardiograms were performed before both procedures, immediately afterwards and at a three-month follow-up. The New York Heart Association (NYHA) functional class was obtained before the procedures and at follow-up. RESULTS: Interventricular septal thickness was significantly reduced at follow-up in both groups (2.3 +/- 0.4 cm vs. 1.9 +/- 0.4 cm for septal ablation and 2.4 +/- 0.6 cm vs. 1.7 +/- 0.2 cm for myectomy, both p 〈 0.001). Estimated by continuous-wave Doppler, the resting pressure gradient (PG) across the left ventricular outflow tract (LVOT) significantly decreased immediately after the procedures in both groups (64 +/- 39 mm Hg vs. 28 +/- 29 mm Hg for PTSMA, 62 +/- 43 mm Hg vs. 7 +/- 7 mm Hg for myectomy, both p 〈 0.0001). At three-month follow-up, the resting PG remained lower in the PTSMA and myectomy groups (24 +/- 19 mm Hg and 11 +/- 6 mm Hg, respectively, vs. those before procedures, both p 〈 0.0001). The NYHA functional class was also significantly improved in both groups (3.5 +/- 0.5 vs. 1.9 +/- 0.7 for PTSMA, 3.3 +/- 0.5 vs. 1.5 +/- 0.7 for myectomy, both p 〈 0.0001). CONCLUSIONS: Both myectomy and PTSMA reduce LVOT obstruction and significantly improve NYHA functional class in patients with HOCM. However, there are benefits and drawbacks for each therapeutic method that must be counterbalanced when deciding on treatment for LVOT obstruction.
    Keywords: Life Sciences (General)
    Type: Journal of the American College of Cardiology (ISSN 0735-1097); 38; 7; 1994-2000
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Publication Date: 2019-07-13
    Description: The physiological effects of various hyperpolarized helium and xenon MRI-compatible breathing protocols were investigated in 17 Sprague-Dawley rats, by continuous monitoring of blood oxygen saturation, heart rate, EKG, temperature and endotracheal pressure. The protocols included alternating breaths of pure noble gas and oxygen, continuous breaths of pure noble gas, breath-holds of pure noble gas for varying durations, and helium breath-holds preceded by two helium rinses. Alternate-breath protocols up to 128 breaths caused a decrease in oxygen saturation level of less than 5% for either helium or xenon, whereas 16 continuous-breaths caused a 31.5% +/- 2.3% decrease in oxygen saturation for helium and a 30.7% +/- 1. 3% decrease for xenon. Breath-hold protocols up to 25 s did not cause the oxygen saturation to fall below 90% for either of the noble gases. Oxygen saturation values below 90% are considered pathological. At 30 s of breath-hold, the blood oxygen saturation dropped precipitously to 82% +/- 0.6% for helium, and to 76.5% +/- 7. 4% for xenon. Breath-holds longer than 10 s preceded by pre-rinses caused oxygen saturation to drop below 90%. These findings demonstrate the need for standardized noble gas inhalation procedures that have been carefully tested, and for continuous physiological monitoring to ensure the safety of the subject. We find short breath-hold and alternate-breath protocols to be safe procedures for use in hyperpolarized noble gas MRI experiments. Copyright 2000 John Wiley & Sons, Ltd.
    Keywords: Life Sciences (General)
    Type: NMR in biomedicine (ISSN 0952-3480); 13; 4; 253-64
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Publication Date: 2019-07-13
    Description: OBJECTIVES: We hypothesized that color M-mode (CMM) images could be used to solve the Euler equation, yielding regional pressure gradients along the scanline, which could then be integrated to yield the unsteady Bernoulli equation and estimate noninvasively both the convective and inertial components of the transmitral pressure difference. BACKGROUND: Pulsed and continuous wave Doppler velocity measurements are routinely used clinically to assess severity of stenotic and regurgitant valves. However, only the convective component of the pressure gradient is measured, thereby neglecting the contribution of inertial forces, which may be significant, particularly for nonstenotic valves. Color M-mode provides a spatiotemporal representation of flow across the mitral valve. METHODS: In eight patients undergoing coronary artery bypass grafting, high-fidelity left atrial and ventricular pressure measurements were obtained synchronously with transmitral CMM digital recordings. The instantaneous diastolic transmitral pressure difference was computed from the M-mode spatiotemporal velocity distribution using the unsteady flow form of the Bernoulli equation and was compared to the catheter measurements. RESULTS: From 56 beats in 16 hemodynamic stages, inclusion of the inertial term ([deltapI]max = 1.78+/-1.30 mm Hg) in the noninvasive pressure difference calculation significantly increased the temporal correlation with catheter-based measurement (r = 0.35+/-0.24 vs. 0.81+/-0.15, p〈 0.0001). It also allowed an accurate approximation of the peak pressure difference ([deltapc+I]max = 0.95 [delta(p)cathh]max + 0.24, r = 0.96, p〈0.001, error = 0.08+/-0.54 mm Hg). CONCLUSIONS: Inertial forces are significant components of the maximal pressure drop across the normal mitral valve. These can be accurately estimated noninvasively using CMM recordings of transmitral flow, which should improve the understanding of diastolic filling and function of the heart.
    Keywords: Life Sciences (General)
    Type: Journal of the American College of Cardiology (ISSN 0735-1097); 36; 6; 1942-9
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...