ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Solid phase extraction ; Tetracycline in serum
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A simple and rugged SPE method for the determination of tetracycline (TC), minocycline (MC) and demeclocycline (DCC) in porcine serum by high performance liquid chromatography (HPLC) was developed. The spiked serum sample was pretreated with 2% phosphoric acid followed by a simple and rugged solid-phase extraction procedure using the OasisTM HLB extraction cartridges. High and reproducible recoveries were obtained even though the cartridges were run dry. The extracted sample analytes were injected onto a Waters SymmetryShieldTM RP8 column. The mobile phase was a simple volatile solution containing 0.1% TFA, 2% methanol and 7% acetonitrile in Water. The antibiotics were detected at 350 nm. The calibration curves were linear from 2.0 to 25.0 μg mL−1 of TC and MC with DCC as the internal standard at a concentration of 25.0 μg mL−1. For six replicate analyses, the average recoveries of TC and MC from porcine serum sample fortified at the level of 2.5 μg mL−1 were 96.1% with 1.3% RSD and 101% with 0.54% RSD; at level of 0.5 μg mL−1 the average recoveries were 88% with 1.6% RSD and 97.8% with 1.4% RSD.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 30 (1990), S. 309-310 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Thin-layer ; GC/MS ; Aminocaproic acid in horse urine ; Solid phase extraction
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A rapid and efficient procedure is described for extraction and determination of aminocaproic acid in horse urine. Urine was extracted by passing through a bonded silica column (Bond-Elut). The adsorbed drug was washed free of endogenous materials before being eluted. The extract was then examined by thin-layer chromatography and HPLC. The purity of the extract was determined by gas chromatography-mass spectrometry.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2016-06-07
    Description: Tthe digital processing clock SG 1157/U is described. It is compatible with the PTTI world where it can be driven by an external cesium source. Built-in test equipment shows synchronization with cesium through 1 pulse per second. It is built to be expandable to accommodate future time-keeping needs of the Navy as well as any other time ordered functions. Examples of this expandibility are the inclusion of an unmodulated XR3 time code and the 2137 modulate time code (XR3 with 1 kHz carrier).
    Keywords: LASERS AND MASERS
    Type: NASA. Goddard Space Flight Center Proc. of the 13th Ann. Precise Time and Time Interval (PTTI) Appl. and Planning Meeting; p 325-346
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2016-06-07
    Description: During warmup, crystal oscillators often show a frequency offset as large as 1 part in 10 to the 5th power. If timing information is transferred to the oscillator and then the oscillator is allowed to warmup, a timing error greater than 1 millisecond will occur. For many applications, it is unsuitable to wait for the oscillator to warmup. For medium accuracy timing requirements where overall accuracies in the order of 1 millisecond are required, a no warmup crystal concept was developed. The concept utilizes two crystal oscillator, used sequentially to avoid using a crystal oscillator for timing much higher frequency accuracy once warmed up. The accuracy achieved with practical TCXOs at initial start over a range of temperatures is discussed. A second design utilizing two oven controlled oscillators is also discussed.
    Keywords: LASERS AND MASERS
    Type: NASA. Goddard Space Flight Center Proc. of the 13th Ann. Precise Time and Time Interval (PTTI) Appl. and Planning Meeting; p 831-850
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...