ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 310 (1982), S. 146-153 
    ISSN: 1618-2650
    Keywords: Best. von Lanthan, Cer, Neodym in Anorg. Material, Glas, Praseodymoxid, Aluminium ; Massenspektrometrie/Isotopenverdünnungstechnik ; Thermionisation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Die Spurenbestimmung von La, Ce und Nd durch massenspektrometrische Isotopenverdünnungsanalyse in Laborglas, Praseodymoxid und Aluminiumfolien, welche nach Dotierung mit einem Lanthanoidisotop im Kernreaktor bestrahlt wurden, wird beschrieben. Die gemeinsame Abtrennung der zu analysierenden Lanthanoide aus der Glas- und Aluminiummatrix bzw. ihre Anreicherung gegenüber Praseodym erfolgt über Anionenaustauschchromatographie. Die Ionisation der Proben im Massenspektrometer wird mit Hilfe der Zweiband-Thermionisationstechnik durchgeführt, wobei die Abhängigkeit des Atomionen/ Oxidionen-Verhältnisses von den Ionenquellenbedingungen ermittelt wird. Es können La, Ce und Nd-Gehalte im untersten μg/g-Bereich mit relativen Standardabweichungen zwischen 1–14% bestimmt werden. In den im Kernreaktor bestrahlten Aluminiumproben kann u.a. das 140Ce-Isotop neben einer über 400fach größeren Menge an 139La ermittelt werden. Wesentlicher Vorteil der massenspektrometrischen Isotopenverdünnungsanalyse ist, daß die erhaltenen Ergebnisse relativ richtig sein sollten und auch Isotope bestimmt werden können.
    Notes: Summary The trace determination of La, Ce and Nd by mass spectrometric isotope dilution analysis in laboratory glass, in praseodymium oxide and in aluminium foils which were irridiated in a nuclear reactor after adding a lanthanide isotope is described. The separation of the lanthanides to be analysed from the glass and the aluminium matrix as well as the enrichment from the praseodymium matrix was achieved by anionic exchange chromatography. Ionization of the samples in the mass spectrometer was carried out by double filament thermal ionization technique. The dependence of the atomic ions and lanthanide oxide ions on the ion source conditions was determined. La, Ce and Nd contents in the lower μg/g range could be determined with relative standard deviations of 1–14%. In one of the aluminium foils, the isotope 140Ce e.g. could be analysed in presence of a more than 400 times higher 139La amount. The essential advantage of mass spectrometric isotope dilution analysis is the accuracy of the results and the possibility to analyse isotopes as well as element contents.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 0044-2313
    Keywords: Chemistry ; Inorganic Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Calcium Isotope Separation and Reaction Enthalpy. Calcium Isotope Separation and Determination of Reaction Enthalpy in Ion Exchange Using a Strongly Acidic Cation Exchange ResinIn the system of a strongly acidic cation exchanger/BaCl2 solution the isotope separation between 40Ca2+ and 48Ca2+ is investigated using column experiments. 48Ca2+ is enriched in the solution phase whereas 40Ca2+ is enriched in the resin phase. A strong dependence of the isotope separation effect on the concentration of the BaCl2 solution is found. The isotope separation increases with decreasing concentration. The isotope separation also depends on temperature: the isotope separation effect increases with decreasing temperature. A ΔH-value of  - 5.8 J/mol is determined for the calcium isotope exchange reaction.
    Notes: In säulenchromatographischen Versuchen wird im System stark saurer Kationenaustauscher/BaCl2-Lösung die Isotopenseparation zwischen 40Ca2+ und 48Ca2+ untersucht. 48Ca2+ reichert sich dabei in der Lösung des Systems an. Eine starke Abhängigkeit des Isotopentrenneffekts von der Konzentration des Fremdelektrolyten BaCl2 ist zu beobachten, wobei die Isotopenseparation bei niedrigerer Konzentration zunimmt. Desgleichen erhöht sich der Trenneffekt mit fallender Temperatur. Für die Calciumisotopenaustauschreaktion wird ein ΔH-Wert von  - 5,8 J/mol bestimmt.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...