  • 1
    ISSN: 1572-9591
    Keywords: ITER ; skyshine analysis ; exposure dose rate ; maintenance of an activated TF coil
    Source: Springer Online Journal Archives 1860-2000
    Topics: Energy, Environment Protection, Nuclear Power Engineering
    Notes: Abstract Gamma-ray exposure dose rates at the ITER site boundary were estimated for the cases of removal of a failed activated Toroidal Field (TF) coil from the torus and removal of a failed activated TF coil together with a sector of the activated Vacuum Vessel (VV). Skyshine analyses were performed using the two-dimensional SN radiation transport code, DOT3.5. The exposure gamma-ray dose rates on the ground at the site boundary (presently assumed to be 1 km from the ITER building), were calculated to be 1.1 and 84 μSv/year for removal of the TF coil without and with a VV sector, respectively. The dose rate level for the latter case is close to the tentative radiation limit of 100 μSv/year so an additional ∼14 cm of concrete is required in the ITER building roof to satisfy the criterion for a safety factor often for the site boundary dose rate.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Journal of fusion energy 2 (1982), S. 173-178 
    ISSN: 1572-9591
    Keywords: neutron activation ; neutral beam injectors ; fusion reactors ; doses rates
    Source: Springer Online Journal Archives 1860-2000
    Topics: Energy, Environment Protection, Nuclear Power Engineering
    Notes: Abstract The dose equivalent rates outside the Engineering Test Facility neutral beam injector shield from the induced radioactivity have been calculated for the reactor operating at 1140 MW for 1, 30, and 365 days. The dose rates at one day after shutdown are large even after one day of operation. Depending on the location and operating time, cooling times from 30 days to ∼ 5 years are required before the dose rates are sufficiently low to allow routine maintenance work in the vicinity of the NBI shield.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...