    Publication Date: 2011-08-24
    Description: AVIRIS is a facility consisting of a flight system, a ground data system, a calibration facility, and a full-time operations team. The facility was developed by JPL under funding from NASA. NASA also provides funding for operations and maintenance. The flight system is a whisk-broom imager that acquires data in 224 narrow, contiguous spectral bands covering the solar reflected portion of the electromagnetic spectrum. It is flown aboard the NASA high altitude ER-2 research aircraft. The ground data system is a facility dedicated to the processing and distribution of data acquired by AVIRIS. It operates year round at JPL. The calibration facility consists of a calibration laboratory at JPL and a suite of field instruments and procedures for performing inflight calibration of AVIRIS. A small team of engineers, technicians, and scientists supports a yearly operations schedule that includes 6 months of flight operations, 6 months of routine ground maintenance of the flight system, and year-round data processing and distribution. Details of the AVIRIS system, its performance history, and future plans are described.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Remote Sensing of Environment (ISSN 0034-4257); 44; 2-3; p. 127-143.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2011-08-24
    Description: An upgraded version of AVIRIS, an airborne imaging spectrometer based on a whiskbroom-type scanner coupled via optical fibers to four dispersive spectrometers, that has been in operation since 1987 is described. Emphasis is placed on specific AVIRIS subsystems including foreoptics, fiber optics, and an in-flight reference source; spectrometers and detector dewars; a scan drive mechanism; a signal chain; digital electronics; a tape recorder; calibration systems; and ground support requirements.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: In: Infrared technology XVII; Proceedings of the Meeting, San Diego, CA, July 22-26, 1991 (A93-38376 15-35); p. 164-175.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 2013-08-31
    Description: The AVIRIS instrument has been designed to do high spectral resolution remote sensing of the Earth. Utilizing both silicon and indium antimonide line array detectors, AVIRIS covers the spectral region from 0.41 to 2.45 microns in 10-nm bands. It was designed to fly aboard NASA's U-2 and ER-2 aircraft, where it will simulate the performance of future spacecraft instrumentation. Flying at an altitude of 20 km, it has an instantaneous field of view of 20 m and views a swath over 10 km wide. With an ability to record 40 minutes of data, it can, during a single flight, capture 500 km of flight line.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Airborne Visible/Infrared Imaging Spectrometer (AVIRIS). A Description of the Sensor, Ground Data Processing Facility, Laboratory Calibration, and First Results; Airborne Visible(Inf
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Publication Date: 2019-06-28
    Description: This paper focuses on the design, construction, preliminary testing, and potential applications of three forms of miniaturized analytical instrumentation. The first is an optical fiber instrument for monitoring pH and other cations in aqueous solutions. The instrument couples chemically selective indicators that were immobilized at porous polymeric films with a hardware package that provides the excitation light source, required optical components, and detection and data processing hardware. The second is a new form of a piezoelectric mass sensor. The sensor was fabricated by the deposition of a thin (5.5 micron) film of piezoelectric aluminum nitride (AIN). The completed deposition process yields a thin film resonator (TFR) that is shaped as a 400 micron square and supports a standing bulk acoustic wave in a longitudinal mode at frequencies of approx. 1 GHz. Various deposition and vapor sorption studies indicate that the mass sensitivity of the TFR's rival those of the most sensitive mass sensors currently available, though offering such performance in a markedly smaller device. The third couples a novel form of liquid chromatography with microlithographic miniaturization techniques. The status of the miniaturization effort, the goal of which is to achieve chip-scale separations, is briefly discussed.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA-CR-191988 , NAS 1.26:191988
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Publication Date: 2019-06-28
    Description: The Sacramento Peak Observatory Fast Microphotometer translates an optical system that includes a laser and photodiode detector across the film to scan the Y direction. A stepping motor moves the film gate in the X direction. This arrangement affords high positional accuracy, low noise (0.002 RMS density units), modest speed (5000 points/second), large dynamic range (4.5 density units), high stability (0.005 density units), and low scattered light. The Fast Microphotometer is interfaced to the host computer by a 6502 microprocessor.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Astron. Microdensitometry Conf.; p 243-254
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Publication Date: 2019-06-28
    Description: A lightweight instrument that utilizes resistance-wire electric strain gases to measure propeller-shaft thrust has been developed. A wind-tunnel investigation on a propeller installed, on a single-engine pursuit airplane showed that the instrument gave a reliable indication of propeller-shaft thrust to an accuracy of +/-2 percent within its calibrated range. No attempt was made to determine the relation of indicated shaft thrust to net propeller thrust.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NACA-RM-E9C17
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Publication Date: 2019-06-27
    Description: The application of X-ray topography to semiconductor process control is described, considering the novel features of the high speed camera and the difficulties associated with this technique. The most significant results on the effects of material defects on device performance are presented, including results obtained using wafers processed entirely within this institute. Defects were identified using the X-ray camera and correlations made with probe data. Also included are temperature dependent effects of material defects. Recent applications and improvements of X-ray topographs of silicon-on-sapphire and gallium arsenide are presented with a description of a real time TV system prototype and of the most recent vacuum chuck design. Discussion is included of our promotion of the use of the camera by various semiconductor manufacturers.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA-CR-150459
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Publication Date: 2019-06-27
    Description: Electromagnetic cascades in a lead-emulsion chamber have been studied to determine the effect of air gaps on the upstream sides of the emulsions. Such air gaps cause a change in the form of the radial distribution of electron tracks, making cascades appear older and giving incorrect energy estimates. The number of tracks remaining within a radius r was found to vary as exp(-g/G), where g is the gap thickness. The characteristic gap thickness in mm is G = 3.04 + 1.30 ln (Err per GeV per sq mm) where E is the energy of the initiating gamma ray. Use of this relation provides a significant correction to cascade-energy estimates and allows one to calculate the effect of different gap thicknesses on the energy threshold for visual detection of cascades.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Nuclear Instruments and Methods; 126; 1975
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Publication Date: 2019-06-28
    Description: A principle formerly used in an instrument for cloud detection was further investigated to provide a simple and rapid means for measuring the liquid-water content of clouds at temperatures above and below freezing. The instrument consists of a small cylindrical element so operated at high surface temperatures that the impingement of cloud droplets creates a significant drop in the surface temperature. ? The instrument is sensitive to a wide range of liquid-water content and was calibrated at one set of fixed conditions against rotating multicylinder measurements. The limited conditions of the calibration Included an air temperature of 20 F, an air velocity of 175 miles per hour, and a surface temperature in clear air of 475 F. The results obtained from experiments conducted with the instrument indicate that the principle can be used for measurements in clouds at temperatures above and below freezing. Calibrations for ranges of airspeed, air temperature, and air density will be necessary to adapt the Instrument for general flight use.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NACA-RM-E50J12A
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Publication Date: 2019-06-27
    Description: A ten-channel analog switch has been developed as a sample and shape circuit for signals used as inputs to a logarithmic pulse height recording system. The circuit employs a field effect transistor as the switching element. Switching transients are reduced to approximately 2 mV by adding to the gated signal an inverted transient generated by an identical circuit with no signal applied. The circuit is linear to 2% from 3 mV to 10 V.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Nuclear Instruments and Methods; 121; 1974
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...