ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • INSTRUMENTATION AND PHOTOGRAPHY  (11)
  • LASERS AND MASERS  (4)
  • 1
    Publication Date: 2011-08-16
    Description: It is pointed out that the first successful infrared heterodyne spectrometer featuring semituneable semiconductor diode lasers was constructed and used near 8.5 micrometers to make laboratory measurements of line profiles in nitrous oxide and to detect thermal emission from Mars and from the moon. Questions of instrument design are discussed along with the significance of the results obtained in the investigation.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Nature; 253; Feb. 13
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2011-08-16
    Description: The factors determining the sensitivity of a real astronomical heterodyne spectrometer are described. The deviation from the ideal heterodyne system for line detection is described in terms of a series of degradation factors. A discussion of degradation due to a low local oscillator power and to line profile detection is presented. Representative values for the degradation factors are given. Even with a total degradation of not less than 30, the heterodyne spectrometer is still found to be a highly sensitive tool in IR astronomy.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 2011-08-16
    Description: The performance of an upconversion system is examined for observation of astronomical sources in the low to middle IR spectral range. Theoretical values for the performance parameters of an upconversion system for astronomical observations are evaluated in terms of the conversion efficiencies, spectral resolution, field of view minimum detectable source brightness, and source flux. Experimental results of blackbody measurements and molecular absorption-spectrum measurements using a lithium niobate upconverter with an argon-ion laser as the pump are presented. Estimates are given of the expected optimum sensitivity of an upconversion device that may be built with presently available components.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Applied Optics; 15; Apr. 197
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Publication Date: 2011-08-16
    Description: Black body measurements and absorption spectra of methane near 3.3 microns are presented and used as examples in a discussion of upconversion spectrometry for astrophysical application. Factors determining the system conversion efficiency and the minimum detectable flux for a typical system are presented. The spectrometer described uses an Argon-ion laser and a temperature turned LiNbO3 crystal in a CW mode. Satisfactory agreement between measured and calculated performance parameters is obtained. An estimate of the highest performance parameters attainable using current technology is given.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Publication Date: 2011-08-17
    Description: Absolute line-center frequencies for eleven lines of ammonia in near coincidence with CO2-laser transitions have been determined to accuracies of + or -3 MHz by infrared heterodyne detection. These results were obtained by heterodyning a blackbody with a stable grating-tuned CO2 gas laser. A discussion of the apparatus and method of calculation, including error analysis, is presented. With these accurately determined line-center positions, the ammonia molecule will be a useful secondary-frequency standard for diode-laser spectroscopy in the 11-micron wavelength region.
    Keywords: LASERS AND MASERS
    Type: Optics Letters; 1; Sept
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Publication Date: 2011-08-16
    Description: A discussion and an evaluation of the degradation in sensitivity are given for a heterodyne spectrometer employing a HgCdTe photodiode mixer and tunable diode lasers. The minimum detectable source brightness is considered as a function of the mixer parameters, transmission coefficient of the beam splitter, and local oscillator emission powers. The degradation in the minimum detectable line source brightness that results from the bandwidth being a fraction of the line width is evaluated and plotted as a function of the wavelength and bandwidth for various temperature to mass ratios. It is shown that the minimum achievable degradation in the sensitivity of a practical astronomical heterodyne spectrometer is about 30. Estimates of SNRs with which IR line emission from astronomical sources of interest may be detected are given.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Applied Optics; 15; Feb. 197
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Publication Date: 2011-08-17
    Description: Infrared heterodyne spectroscopy provides a means of measuring the intensity profiles of individual rotation-vibration spectral lines with high sensitivity. Considerable effort has been expended on optimizing these instruments for remote measurements of gases in planetary atmospheres with the result that present-generation spectrometers are beginning to provide new and startling results on the planets. The fundamental principles of laser heterodyne spectroscopy are discussed. Detailed considerations of the optical design and the electronic design of the spectral-line receiver are given. Representative results obtained with this spectrometer are discussed, including precision frequency measurements of NH3 (nu-2) lines, detection of auroral emission from Jupiter, and measurements of terrestrial O3 and CO2.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Optical Engineering; 17; Jan
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Publication Date: 2011-08-19
    Description: The technique of laser heterodyne spectroscopy has been applied to the measurement of solar oscillations. Coherent mixing of solar radiation with the output of a frequency-stabilized CO2 laser permits the measurement of fully resolved profiles of solar absorption lines with high spectral purity and excellent frequency stability. This technique has been used to measure OH pure rotation lines in the infrared solar spectrum. Power spectra of these line frequency measurements show the well-known 5-min oscillations as well as significant velocity power at shorter periods.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Applied Optics (ISSN 0003-6935); 25; 58-62
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Publication Date: 2011-08-18
    Description: A diode-laser-based, ultrahigh resolution IR heterodyne spectrometer for laboratory and field use has been developed for operation between 7.5 and 8.5 microns. The local oscillator is a PbSe tunable diode laser kept continuously at operating temperatures of 12-60 K using a closed-cycle cooler. The laser output frequency is controlled and stabilized using a high-precision diode current supply, constant temperature controller, and a shock isolator mounted between the refrigerator cold tip and the diode mount. The system largely employs reflecting optics to minimize losses from internal reflection and absorption and to eliminate chromatic effects. Spectral analysis of the diode-laser output between 0 and 1 GHz reveals excess noise at many diode current settings, which limits the IR spectral regions over which useful heterodyne operation can be achieved. Observations have been made of atmospheric N2O, O3, and CH4 between 1170 and 1200/cm, using both a single-frequency swept IF channel and a 64-channel RF spectral line receiver with a total IF coverage of 1600 MHz.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Applied Optics; 21; Jan. 15
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Publication Date: 2016-06-07
    Description: The optical design considerations for optimization of sensitivity, tunability, and versatility of an infrared heterodyne spectrometer are discussed using the GSFC CO2 laser heterodyne spectrometer optical front end as an example. Problems related to the coherent nature of the laser local oscillator beam (e.g., interference effects at edges of optical elements and at the beam combining beamsplitter) are described and proper beamsplitter design discussed. Optimum matching to the telescope is discussed. The severe effects of large central obscuration on the coherent telescope efficiency are described and steps to partially recover the lost system sensitivity are proposed. Measurements made with the GSFC 48 inch telescope (linear obscuration rate = 0.5) and the KPNO McMathe telescope (no obscuration) are given as examples.
    Keywords: LASERS AND MASERS
    Type: NASA. Langley Res. Center Heterodyne Systems and Technol., Pt. 2; p 365-372
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...