ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • INSTRUMENTATION AND PHOTOGRAPHY  (2)
  • 1985-1989  (2)
Collection
Keywords
Years
Year
  • 1
    Publication Date: 2011-08-19
    Description: Results from an intercomparison of techniques to measure tropospheric levels of carbon monoxide (CO) are discussed. The intercomparison was conducted as part of the National Aeronautics and Space Administration's Global Tropospheric Experiment (GTE) and was held at Wallops Island, VA, in July 1983. Instruments intercompared included a laser differential absorption method and three grab sample/gas chromatograph methods. The intercomparison consisted of simultaneous measurements of ambient levels of CO and controlled injections of CO from a common manifold. Results from the techniques exhibited a high degree of correlation among themselves and with changes in the CO mixing ratio. The results suggested a level of agreement among the techniques of about 15 percent. However, a day-to-day bias between the techniques was observed, which resulted in differences between techniques as large as 38 percent.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Journal of Geophysical Research (ISSN 0148-0227); 90; 12
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2019-07-12
    Description: The instrumental and data-reduction techniques used in obtaining remote measurements of carbon monoxide during the 1979 Summer Monsoon Experiment are described. The form of the signal function (the variation of signal with altitude) and the impact of variations in the vertical distribution of carbon monoxide are discussed. Estimates of the experimental accuracy are made both by assessment of error sources through the use of numerical simulations and by comparison with concurrent measurements made by means of gas chromatography. It is found that the radiometric measurements tend to be about 9 percent lower than the direct measurements and to have a precision of about 8 percent.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Journal of Geophysical Research (ISSN 0148-0227); 91; 9841-984
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...