ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Human  (2)
  • Industrial Chemistry  (2)
  • 21.60.Ev  (1)
  • 1
    ISSN: 1434-601X
    Keywords: 21.10.Re ; 21.60.Ev ; 23.20.Lv ; 27.90. + b
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract We report on a measurement of the lifetime of the 1414 keV state in232Th by the Doppler-shift recoil-distance method. This 4+ state shows all characteristics of a nearly-harmonic two-phononγ-vibrational excitation. The result for the B(E2) value obtained from the lifetime,τ=3.2 ± 0.7 ps, is in agreement with an earlier estimate of the collectivity from Coulomb-excitation yields and supports the interpretation of the 1414 keV state as a two-phononγ-vibrational excitation.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-0878
    Keywords: Key words: Placental stem villi ; Perivascular contractile sheath ; Molecules of adhesion plaques ; Extracellular matrix molecules ; Immunocytochemistry ; Human
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Notes: Abstract. In previous studies, we have shown that smooth muscle cells and myofibroblast subpopulations of the perivascular stem villous sheath of the human placenta contain focal adhesion plaques and talin immunoreactivity. The close association of these cells to elastic and collagen fibres have led to the assumption of a functional myofibroelastic unit within the perivascular stem villous sheath. Interactions between the extracellular matrix and smooth muscle cells depend on a variety of structural protein assemblies. In the present study, we examined, by immunocytochemistry, whether the molecular assembly of extracellular matrix proteins and molecules of focal adhesions, known to be essential for signal transduction in smooth muscle cells, are also found in smooth muscle cells of the perivascular stem villous sheath of the human placenta. Vascular and extravascular smooth muscle cells were immunoreactive for α-actinin, vinculin, paxillin and tensin, the integrin chains α1 and β1, and the basement membrane components laminin and heparan/-chondroitin sulfate proteoglycan perlecan. pp125FAK did not react. In the extracellular matrix of blood vessel walls and the perivascular stem villous sheath, we found immunoreactivity of fibronectin and collagen types I, VI and undulin (collagen type XIV). From our data we conclude that within the perivascular stem villous sheath, there exists a system of signal transduction molecules, indicating a cross talk between the smooth muscle cells of this sheath and their surrounding extracellular matrix.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1432-0878
    Keywords: Key words: Elastic fibres ; Placental stem villi ; Extravascular smooth muscle cells ; Adhesion plaques ; Talin immunoreactivity ; Human
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Notes: Abstract. The stroma of human placental stem villi is believed to consist only of reticular and collagen fibres. In the present study we were able to show for the first time by light (orcein staining) and electron microscopy large amounts of elastic fibres in the stem villous stroma. Electron microscopically, homogeneous elastin was found alone or in association with microfibrils. In addition, microfibrils were observed forming long bands. These three structures, generally known to form elastic connective tissue, were seen in close connection with placental extravascular smooth muscle cells, which belong to the perivascular contractile sheath (PVCS) of stem villi. Elastin was associated with these smooth muscle cells and connected to collagen fibres via microfibrils. Collagen fibres were additionally interconnected by spike-like structures. Extravascular smooth muscle cells revealed numerous adhesion plaques which occupied conspicuously long cytoplasmic faces of the plasma membrane. In cryostat sections, immunoreactivity of talin, an attachment protein of adhesion plaques linking intracellular α-actin filaments with extracellular fibronectin, was detected in extravascular and vascular (media) smooth muscle cells. The arrangement of placental extravascular smooth muscle cells, elastic and collagen fibres suggests a functional myofibroelastic unit within the PVCS, which surrounds the large foetal blood vessels possibly contributing to elasticity and supporting tensile and/or contracting forces within the stem villi.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 0009-286X
    Keywords: Chemistry ; Industrial Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Nach Besprechung der Problematik der Elektrodenkinetik werden die Grundzüge der Theorie der Überspannung diskutiert. Für das Auftreten der Überspannung sind bei Redoxprozessen drei Arten der Hemmung, die der Diffusion, die des Elektronendurchtritts durch die elektrolytische Doppelschicht und die einer vor- oder nachgelagerten homogenen oder heterogenen chemischen Reaktion verantwortlich. Aus der Konzentrationsabhängigkeit der Durchtrittsüberspannung bzw. der Austauschstromdichte können anodische und kathodische elektrochemische Reaktionsordnungen bestimmt werden. Mit Hilfe dieser Größen kann die Durchtrittsreaktion, also der Ladungsübergang an der Phasengrenze, ermittelt werden. Aus der Konzentrationsabhängigkeit der Reaktionsüberspannung bzw. der Reaktionsgrenzstromdichten können chemische Reaktionsordnungen bestimmt werden, die die Erfassung der vor- bzw. nachgelagerten chemischen Reaktionen erlauben. - Für die Messungen der Überspannungsanteile wird die Ermittlung der Stromdichte-Überspannungskurven mittels galvanostatischer und potentiostatischer stationärer Methoden und Impulsmethoden behandelt. Die Ermittlung des ohmschen Spannungsabfalls im Elektrolyten wird besprochen. Als weitere Methode wird die Messung der Elektrodenimpedanz als Funktion der Frequenz diskutiert. Abschließend wird die Ermittlung von Zwischenprodukten mit Hilfe der rotierenden Scheiben- und Ringelektrode, aus Transitionszeitmessungen bei Doppelimpulsen und mit der Elektronen-Spin-Resonanz-Methode behandelt.
    Additional Material: 16 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 0009-286X
    Keywords: Chemistry ; Industrial Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Technische Anodenmaterialien müssen aus Gründen der Haltbarkeit eine geringe Korrosion und aus energetischen Gründen eine kleine Überspannung des Anodenprozesses aufweisen. Die maximale Korrosion im aktiven Zustand wird mit und ohne Komplexbildung auf der Grundlage diskutiert, daß Diffusionsvorgänge begrenzend sind. Hierbei wird auch die Bildung von porösen Deckschichten bei schwerer löslichen Korrosionsprodukten berücksichtigt. Die Korrosion im passiven Zustand wird als Eigenschaft der porenfreien Passivschicht an verschiedenen Beispielen behandelt und das Flade-Potential für den Übergang aktiv/passiv und dessen Eigenschaften diskutiert. Der Einfluß von pH-Wert und Komplexbildnern auf die passive Korrosion wird behandelt. - Anodenprozesse, hier also Redoxprozesse wie anodische Sauerstoffoder Chlor-Entwicklung, können an passiven Elektroden nur ablaufen, wenn die Passivschicht eine ausreichende Elektronenleitfähigkeit hat. An Aluminium, Titan und Tantal als Beispiel ist das nicht der Fall. Die Überspannung ist an passiven Anoden eine Eigenschaft der Passivschicht an der elektrolytseitigen Phasengrenze. - Halbleitermaterialien und Graphit werden als Anodenmaterialien gesondert diskutiert.
    Additional Material: 13 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...