ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 57-64 
    ISSN: 0935-6304
    Keywords: Gas Chromatography ; Capillary, glass ; Splitless injection, basis of ; Use for any sample ; Optimization ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Splitless injection is based on the solvent effect as a mechanism condensing large vapour clouds down to infinitely shortened bands. The effect is controlled by the parameters column temperature, volatility and amount of solvent, and rate of injection. By properly selecting the variables the effect can easily be optimized for any combination of sample and column. It is the purpose of this paper to provide the mechanistic understanding as required for this optimization, as well as some rules for the experimental realization. Potentialities and limitations of splitless injection are discussed, and the role of the solvent effect in on-column injection is emphasized.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 149-155 
    ISSN: 0935-6304
    Keywords: Gas Chromatography ; Capillary, glass ; Preparation of apolar columns ; Ba CO3 procedure optimized for thermostability acid/base behaviour and efficiency ; New, quantitative testing procedure ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: As an extension of previous reports, the barium carbonate procedure has been optimized in detail for the preparation of apolar columns. The aim was to produce optimum overall column characteristics, and to maintain them unchanged under the prolonged influence of the highest possible temperature. The main parameters under optimization were glass variety, leaching of glass surface with aqueous HCl, and amount of barium carbonate deposited, while deactivation and coating were kept constant. The basic column characteristics were adsorption properties and thermostability of deactivation, acid/base behaviour and separation efficiency. They were determined by a new, quantitative testing procedure. Intense leaching was able to eliminate almost totally the differences between glass varieties and to create a well-defined glass surface. While untreated glass, leached glass, and barium carbonate treated glass showed specific weak points in the respective column quality, the combination of leaching and barium carbonate treatment yielded the highest and most stable quality. Some technical modifications of the preparation procedure are described, including deactivation in the gas phase, and use of pentane as a solvent for static coating.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 15-21 
    ISSN: 0935-6304
    Keywords: Gas Chromatography ; Capillary ; Injection errors by sample discrimination ; Specific sorption within the syringe needle ; Pull back sample insert needle, warm up, inject than ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The discrimination of the high boiling components of a C9 to C44 alkane test mixture in a vaporizing injector (analysed with stream splitting on a capillary column) is mainly due to a selective elution of the sample out of the syringe needle. Different methods of handling the syringe needle are tested. The discrimination is quantitated and correlated with the material left in the needle. The poorest method of injection was found to retain the sample in the needle when the latter is introduced into the vaporizer. The sample should be pulled back into the barrel of the syringe and the needle allowed to warm up in the injector before the sample is transferred into it. The solvent flush technique may be preferred for components sensitive to the hot metal surface of the needle.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 93-94 
    ISSN: 0935-6304
    Keywords: Gas Chromatography ; Capillary, glass ; Static coating, apolar gums ; Pentane better than methylene chloride, ready in 8 hours ; (20 m, 0.3 mm i.d.) ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 94-95 
    ISSN: 0935-6304
    Keywords: Gas Chromatography ; Capillary, glass ; Quantitative analysis of unsaturated fatty methyl esters ; Remarkable systematic errors of cis/trans determination ; Errors depend on phases chosen ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 98-99 
    ISSN: 0935-6304
    Keywords: Gas Chromatography ; Capillary, glass ; Quantitative analysis of higher alcohols ; Direct injection of beverages, liqueurs etc ; Inner standard dioxan, inlet modification ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 103-104 
    ISSN: 0935-6304
    Keywords: Gas Chromatography ; Capillary, glass ; Fittings, remaining elastic till 300°C ; Important details of proper handling ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 221-222 
    ISSN: 0935-6304
    Keywords: Gas Chromatography ; Capillary, glass ; Solution of liquid phase ; Stored solutions produce less thermostable columns ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 307-308 
    ISSN: 0935-6304
    Keywords: Gas Chromatography ; capillary, glass, diagnosis of damage ; repair by partial washing ; partial reimpregnation/deactivation ; repair test ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...