This paper is concerned with the results of a study designed to evaluate experimentally the accuracy and precision of electrochemical concentration cell (ECC) ozonesondes as prepared and flown by NASA, as a function of altitude. A combination of dual-instrument soundings and laboratory work using an environmental chamber was employed in the study. The ECC ozonesonde is a small, balloon-borne sensor developed for obtaining vertical profiles of atmospheric ozone. Attention is given to the design of the employed environmental chamber, ozone and temperature profiles used in simulated ozonesonde soundings, absolute and relative ECC ozonesonde precision estimates determined with the environmental chamber and from dual-instrument balloon soundings, and the ECC ozonesonde accuracy.