    Publication Date: 2005-11-30
    Description: Theoretical considerations of lightning phenomena and the effects of the magnetic, capacitive, and resistive components of lightning-induced voltages are discussed. A typical tracking station is analyzed from a lightning standpoint. Specific protective methods are discussed, including the implementation of high-surge-current voltage clippers for sensitive electrical and electronic circuits, grounding, counterpoises, and bonding. The safety of operating personnel is also treated as a prime consideration.
    Keywords: FACILITIES, RESEARCH, AND SUPPORT
    Type: NASA. Goddard Space Flight Center Radio Freq. Interference Handbook; p 199-253
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 17 (1983), S. 931-943 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: A study using an electro-osmotic cell suitable for actuating an implantable insulin micropump showed that controlled variable flow rates in the order of 0.2 mL/day are possible. The cell functioned continuously with low energy and power requirements and long service life. The principle of operation is compatible with achieving the very low flow rates necessary if highly concentrated insulin is to be used to avoid frequent insulin reservoir refilling. An electro-osmotic cell, Ag/ AgCl/NaCl(aq)/ cation exchange membrane/NaCl(aq)/ AgCl/ Ag, was connected to a constant current power supply which reversed the direction of the current every 10 mins causing a to-and-fro transport of fluid through the membrane. Flow rates of 0.15-0.60 μL/min were achieved with currents of 2.5-10 mA. At the low flow rate, energy consumption was 6.4 × 10-2 J/μL and peak power requirement was 〈2.0 × 10-4 W. Fluid was transported against a pressure gradient of 52 cm Hg. The cell contained a total electrolyte volume of 〈0.25 mL. The membrane showed no change in properties after 10,000 current reversals (69 days). To function as an actuator for an implantable insulin micropump, the electro-osmotic cell requires a switching and valving assembly; a suitable design for this is briefly considered.
    Additional Material: 5 Ill.