  • 1
    Publication Date: 2019-07-12
    Description: Faults in wiring systems are a serious concern for the aerospace and aeronautic (commercial, military, and civilian) industries. Circuit failures and vehicle accidents have occurred and have been attributed to faulty wiring created by open and/or short circuits. Often, such circuit failures occur due to vibration during vehicle launch or operation. Therefore, developing non-intrusive fault-tolerant techniques is necessary to detect circuit faults and automatically route signals through alternate recovery paths while the vehicle or lunar surface systems equipment is in operation. Electrical connector concepts combining dust mitigation strategies and cable diagnostic technologies have significant application for lunar and Martian surface systems, as well as for dusty terrestrial applications. The dust-tolerant intelligent electrical connection system has several novel concepts and unique features. It combines intelligent cable diagnostics (health monitoring) and automatic circuit routing capabilities into a dust-tolerant electrical umbilical. It retrofits a clamshell protective dust cover to an existing connector for reduced gravity operation, and features a universal connector housing with three styles of dust protection: inverted cap, rotating cap, and clamshell. It uses a self-healing membrane as a dust barrier for electrical connectors where required, while also combining lotus leaf technology for applications where a dust-resistant coating providing low surface tension is needed to mitigate Van der Waals forces, thereby disallowing dust particle adhesion to connector surfaces. It also permits using a ruggedized iris mechanism with an embedded electrodynamic dust shield as a dust barrier for electrical connectors where required.
    Keywords: Electronics and Electrical Engineering
    Type: KSC-13578 , NASA Tech Briefs, February 2012; 9-10
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2019-08-24
    Description: Methods and systems may provide for debris exclusion and removal apparatuses for connectors which have inverting end caps with a multi-axis lever configuration, inverting end caps with enlarged handle and/or side rail configurations, rotating end cap configurations, poppet valve configurations, O-ring configurations, filament barrier configurations, retractable cover configurations, clamshell end cap configurations, or any combination thereof. Apparatuses may also provide for an intelligent electrical connector system capable of detecting damage to or faults within a plurality of conductors and then rerouting the energy through a non-damaged spare conductor.
    Keywords: Electronics and Electrical Engineering
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 2019-08-28
    Description: A debris exclusion and removal system for connectors which have a filament barrier configuration designed to clean connectors as they are mated together.
    Keywords: Electronics and Electrical Engineering
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Publication Date: 2019-07-13
    Description: A number of JPL missions, either active or in the p l d g stages, require the accurate LILT flew intensity - low temperate) climate of triple-junction solar. Although triple ignition LILT performance was reported as recently as 2002, there has been an evolutionary advance in cell technology by both U.S. space cell manufacturers that, for mission design purposes, effectively obsoletes the earlier data. As a result, JPL initiated a program to develop a database for the LILT performance of the new high performance triple junction solar cells. JPL obtained Emcore Advanced triple Juntion CIC assemblies and Spectrolab Ultra Triple Junction CIC assemblies. These cells were tested at temperature-intensity ranges designed to cover applications between 1 and 5.18 AU solar distances. 1 MeV electron irradiation from 25 E14 to 1 El5 w were performed on the cells to evaluate the combined effect of particulate radiation and LILT conditions. The effect of LILT conditions was observed to incur an increase in the variation of cell performances such that at simulted 5.18 AU conditions the average performance was approximately 30% with the best cells measuring between 32 and 34% efficiency. The 30% average efficiency compares with approximately 25% average efficiency measured on earlier technology triple junction solar cells.
    Keywords: Electronics and Electrical Engineering
    Type: 2nd Annual International Energy Conversion Engineering Conference (IECEC); Aug 16, 2004 - Aug 19, 2004; Providence, RI; United States
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...